8
Two operators hold the handle arms at two sides of inverter, as shown in Figure 3, take out the inverter from the
packing box and carry it to the installation location.
Fig 3 Handling method
3.3 Mounting
CAUTION
Danger to life if installed in improper locations
The mounting location or bracket must be suitable for the weight and
dimensions of the inverter.
CAUTION
Carefully aim at the position and gently hang the inverter on the mounting
frame. Falling may result in damage to inverter or danger to life.
EA33/40KTLSI inverter is suited for indoor and outdoor installation and corresponds to degree of protection IP65.
Mount on a solid support surface. It must be suitable for the weight and dimension of the inverter. The mechanical
dimension of EA33/40KTLSI is 580mmx820mmx255mm (WxHxD), weigh about 65kg.
In order to maintain sufficient ventilation and service access, a clearance between the inverter and surrounding
objects should be observed as following (as shown in Figure 4) :
≥ 200mm at the sides; ≥ 500mm at the top; ≥
300mm at the underside; ≥ 1000mm from the front.
According to the EMC and noise level, the inverter is applicable to industrial environment and should be installed
away from living area as far as possible.
Mount vertically or tilted backwards by max. 15°. Never mount it with a forward tilt. The wiring terminal should be
down.
Place the wall mounting bracket (see Figure 5) against a suitable wall with explosion screws, aim the groove of the
hanging backboard of the inverter at the convex edge of the wall mounting bracket, then attach the inverter to the
wall mounting bracket.
Fig. 4 Minimum clearance Fig. 5 Wall mounting bracket