HSU - MANUAL // PAGE 17
8 ADDITIONAL INFORMATION
8.1 SOFTWARE-DEPENDENT FUNCTIONS
A full list of Software-Dependent Functions can be found in the Manual of the installed Control Box.
8.2 DISASSEMBLY
To disassemble the HSU, disconnect the Control Box from the mains. Then, follow the assembly instruc-
tions in reverse order.
8.3 MAINTENANCE
All HSU Handsets are maintenance-free for their entire service lifetime.
WARNING Risk of death or serious injury through electric shocks and other hazards
Using a Handset alongside unauthorized spare or accessory parts may lead to death or
serious injury through electric shocks and other hazards.
• Only use accessory parts produced or approved by LOGICDATA
• Only use replacement parts produced or approved by LOGICDATA
• Only allow Skilled Persons to perform repairs or install accessory parts
• Contact customer services immediately if the system malfunctions
The use of unauthorized spare or accessory parts may cause system damage. Warranty
claims are void in this scenario.
8.3.1 CLEANING
1. Disconnect the Control Box from the mains.
2. Wait 30 seconds for residual voltage to dissipate.
3. Wipe the Handset with a dry or slightly damp soft cloth. Never immerse the Handset in liquid.
4. Wait for the Handset to dry completely.
5. Reconnect the Control Box.
8.3.2 REPLACING A HANDSET
1. Disconnect the Control Box from the Mains.
2. Disconnect the Handset from the Control Box.
3. Remove the Handset from the Table Top.
4. Mount the new Handset onto the Table Top.
5. Plug the Handset back into the Control Box.
6. Reconnect the Control Box to the Mains.