background image

 

Page 6 / 11 

2.6 

Handswitch Plug 

Pin assignment 

Handswitch connector 
 

3

2

1

5

4

7

6

 

 
(pin alignment according to DIN 45329) 
 

 

Caution:

  The  HSU  handswitch  is  only  suitable  for  LOGICDATA  motor 

controls.  To  prevent  damage  of  the  unit,  take  care  not  to  interchange 
handswitch and motor sockets.  

Colour code:

 

Handswitch: blue 

 

 

 

Motor: black 

 

3.  Mounting Instructions 

Mount the HSU cable-handswitch underside your desktop in an appropriate position.  
Following tools are required for installation: 
 

  1 screw driver 

 
Please take note, that the handswitch is equipped with a shift mechanism. Therefore 
always mount the handswitch in a drawn in position. 
 
1.  Unpack the handswitch. 
 

 

Note:

  Dispose  of  the  packaging  material  ecologically  sound  (separate 

plastic foil and cardboard)! 

 
2.  Place the handswitch on the underside of your desktop on the position of choice. 

Note that the handswitch should be reached comfortably.  Its front side should not 
protrude over the table’s edge. 

 
3.  Fix the mounting plate with the 6 enclosed screws. 

HS1  

 

 

HS4 

HS3 

 

 

+5V 

n.c. 

 

 

SER_OUT 

HS2 

 

Shield 

 

GND 

n.c. 

not connected 

Содержание HSU

Страница 1: ...t responsibility for incorrect operation or use of the products other than for the intended purpose Under the warranty terms LOGICDATA shall replace or repair any products that prove defective at the...

Страница 2: ...2 5 Overview 4 2 6 Handswitch Plug 6 3 Mounting Instructions 6 4 Functions 8 4 1 Display 8 4 2 Basic Functions 8 4 3 Advanced Functions 9 4 3 1 Storing a position 9 4 3 2 Recalling a saved position 9...

Страница 3: ...han described above is only allowed with permission of LOGICDATA Information For all information concerning LOGICDATA control boxes please refer to the corresponding manual 2 2 Definition Information...

Страница 4: ...ing plate screws Danger Use only genuine replacement parts Repairs must be carried out only by a qualified service technician If you neglect to do so you void your warranty 2 5 Overview Desk upwards D...

Страница 5: ...Page 5 11 Desk upwards Desk downwards Display Figure 3 HSU MDF 2 LD Desk downwards Desk upwards Figure 4 HSU OD 2 LD...

Страница 6: ...owing tools are required for installation 1 screw driver Please take note that the handswitch is equipped with a shift mechanism Therefore always mount the handswitch in a drawn in position 1 Unpack t...

Страница 7: ...rol box using the jack marked with only Do not connect the handswitch plug to the motor jacks Caution Unplug the power cord of the control unit while mounting the handswitch Figure 5 Connect the HSU c...

Страница 8: ...ards For an upward adjustment of the desk push this button Push this button until the desired height of the desk has been reached The desk will continue driving upwards until you release the button or...

Страница 9: ...e g S2 The display reads S 2 4 Now the height is stored on the chosen position button The saving operation is confirmed with a double click sound and after approximately 2 seconds the stored height w...

Страница 10: ...m Without mounting plate Weight 0 3 kg incl Cable Note The foil of the handswitch might perish or might grow pale due to intensive UV radiation Therefore avoid direct solar radiation 6 Appendix 6 1 Po...

Страница 11: ...lution Cable is not plugged Cable is not plugged as intended Plug the plug in the intended jack marked with Bad pin contact Plug off the plug an plug it in as intended as described above Cable is defe...

Отзывы: