background image

DMUI-HSM - MANUAL // PAGE 12

6  ASSEMBLY

This chapter describes the process of installing the DMUI-HSM Handset into the DYNAMIC MOTION System. 

6.1  SAFETY DURING ASSEMBLY

 

WARNING Risk of death or serious injury through electric shocks

DMUI-HSM Handsets are electrical devices. Basic safety precautions must be taken at 

all times. Failure to observe electrical safety precautions may lead to death or serious 

injury through electric shocks. 

•  Never open the Handset

•  Ensure that the Handset is not connected to the Power Unit during assembly

•  Do not convert or modify the Handset in any way

•  Check the housing and cables of the Handset for visible damage. Do not install or 

operate damaged products. 

CAUTION

Risk of minor or moderate injury through improper handling

Improper handling of the product during assembly may lead to minor or moderate in-

jury through cutting, pinching, and crushing.

•  Avoid contact with sharp edges

•  Be careful while handling tools that may cause personal injury

•  Ensure assembly complies with the generally accepted standards and guidelines of 

electrical engineering and furniture manufacturing

•  Read all instructions and safety advice carefully 

CAUTION

Risk of minor or moderate injury through tripping

During assembly and operation, poorly routed Cables may become a trip hazard. 

Tripping over Cables may lead to minor or moderate injury.

•  Ensure that Cables are routed properly to avoid trip hazards

•  Be careful not to trip over Cables when installing the Handset

NOTICE

Ensure proper ESD handling during assembly. Damage that can be attributed to electro-

static discharge will void warranty claims.

NOTICE

To avoid damage to the product, measure the dimensions of the Handset before 

assembly.

NOTICE

Before assembly, all parts must be acclimatised to the ambient conditions.

NOTICE

Do not lift the Handset by its cable. This will cause irreparable damage to the product. 

INFO

Perform a product risk assessment so that you can respond to potential residual haz-

ards. Assembly instructions must be included in your end user Operating Manual.

Содержание DYNAMIC MOTION DMUI-HSM

Страница 1: ...DYNAMIC MOTION system PART OF DYNAMIC MOTION DMUI HSM User Manual DOCUMENT VERSION 1 0 JANUARY 2020...

Страница 2: ...January 2020 This document was originally published in English LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43 0 3462 51...

Страница 3: ...signal words 6 2 6 Liability 6 2 7 Residual risks 7 2 8 Skilled Persons 7 2 9 Notes for Resellers 8 3 Scope of delivery 8 4 Unpackaging 8 5 Product 9 5 1 Key Product Features 9 5 2 Dimensions 10 5 3 D...

Страница 4: ...payment of the product all text and images in Chapter 2 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user documentation for Height...

Страница 5: ...t national worker protection conditions and national safety and accident prevention regulations are observed during operation of the system 2 3 INTENDED USE The DMUI HSM is a Handset for electrically...

Страница 6: ...INFO Indicates important tips for handling the product 2 6 LIABILITY LOGICDATA products comply with all currently applicable health and safety regulations However risk can result from incorrect operat...

Страница 7: ...ry through explosions Read the relevant directives to determine if an atmosphere is potentially explosive Do not operate the Handset in potentially explosive atmospheres CAUTION Risk of minor or moder...

Страница 8: ...ec For table systems that will be sold or used in Quebec Resellers must provide all product relevant texts in French These include but are not limited to Operating Manuals All other product documentat...

Страница 9: ...The exact variant of the DMUI HSM is denoted by the prod uct s order code Consult the accompanying datasheet to ensure that you have received the correct variant 5 1 KEY PRODUCT FEATURES 1 Mounting P...

Страница 10: ...DMUI HSM MANUAL PAGE 10 5 2 DIMENSIONS Length 50 0 mm 1 969 Width 59 9 mm 2 358 Height to underside of Table Top 17 3 mm 0 681 Fig 2 Product dimensions DMUI HSM 17 3mm 0 681 50mm 1 969 59 9mm 2 358...

Страница 11: ...e Top and 43 8 mm apart The Transportation Position allows the DMUI HSM to be slid backwards un derneath the Table Top so that the Handset does protrude from the front edge of the table when in transp...

Страница 12: ...hile handling tools that may cause personal injury Ensure assembly complies with the generally accepted standards and guidelines of electrical engineering and furniture manufacturing Read all instruct...

Страница 13: ...equest 6 3 PROCESS 1 Position the Handset under the table top and mark the position of the Mounting Points 2 Drill the holes for the Mounting Screws into the Table Top at the marked points 3 Use the s...

Страница 14: ...sconnect the Power Hub from the Mains Check the Power Hub for overheating Let cool if necessary Check all cable connections and reconnect the system If problem persists Perform a Position Reset Proced...

Страница 15: ...hrough crushing Your fingers may be crushed when you attempt to change the height of the table Keep fingers away from moving parts Ensure that no persons or objects are in the table s range of motion...

Страница 16: ...nario 9 2 1 CLEANING 1 Disconnect the system from the Power Unit 2 Wait 30 seconds for residual voltage to dissipate 3 Wipe the surface of the Handset with a dry or slightly damp soft cloth Never imme...

Страница 17: ...rk 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc 1525 Gezon Parkway SW Suite...

Отзывы: