background image

ACS-CB-SENS - MANUAL // PAGE 5

1  GENERAL INFORMATION

Documentation for the ACS-CB-SENS Collision Sensor consists of this Operating Manual and several other 
documents (Other applicable documents, page 5). Assembly personnel must read all documentation before 
starting assembly.   Keep all documentation for as long as the product is in your possession. Ensure that all 
documentation is provided to subsequent owners. Go to www.logicdata.net for more information and sup-
port. This Manual may change without notice. The most recent version is available on our website.

1.1  OTHER APPLICABLE DOCUMENTS

This Operating Manual contains assembly and operation instructions for the  ACS-CB-SENS  Collision 
Sensor. Other applicable documents include:

•  Datasheet for the ACS-CB-SENS
•  Datasheet for the LOG-PRT-DMS
•  Datasheet for the DMS Cover (if applicable)
•  Datasheet and Operating Manual for the Control Box in the Table System

1.2  COPYRIGHT

© March 2020 by LOGICDATA Electronic und Software Entwicklungs GmbH. All rights reserved, except for 
those listed in Chapter 1.3 Royalty-free use of images and text on page 5.

1.3  ROYALTY-FREE USE OF IMAGES AND TEXT

After purchase and full payment of the product, all text and images in Chapter 2 “Safety”, may be used free of 
charge by the customer for 10 years after delivery. They should be used to prepare end user documentation 
for Height-Adjustable Table Systems. The license does not include logos, designs, and page layout elements 
belonging to LOGICDATA. The Reseller may make any necessary changes to the text and images to adapt 
them for the purpose of end user documentation. Texts and images may not be sold in their current state, 
and may not be published or sublicensed digitally. The transfer of this license to third parties without per-
mission from LOGICDATA is excluded. Full ownership and copyright of the text and graphics remain with 
LOGICDATA. Texts and graphics are offered in their current state without warranty or promise of any kind. 
Contact LOGICDATA to obtain text or images in an editable format ([email protected]).

1.4  TRADEMARKS

Documentation may include the representation of registered trademarks of goods or services, as well as 
information about copyright or other proprietary expertise of LOGICDATA or third parties. In all cases, all 
rights remain exclusively with the respective copyright holder. LOGICDATA® is a registered trademark of 
LOGICDATA Electronic & Software GmbH in the USA, the European Union, and other countries.

Содержание ACS-CB-SENS

Страница 1: ...MANUAL Document Version 3 0 March 2020 ACS CB SENS Valid for LOG PRT DMS 300 LOG PRT DMS LD DMS Cover...

Страница 2: ...3 0 March 2020 This document was originally published in English LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43 0 3462...

Страница 3: ...2 7 Residual risks 8 2 8 Skilled Persons 8 2 9 Notes for Resellers 9 3 Scope of delivery 9 4 Unpackaging 9 5 Product 10 5 1 About Intelligent Sensor Protection 10 5 2 Key Product Features 10 5 3 Dimen...

Страница 4: ...4 7 System Information 16 8 Additional Information 17 8 1 Software Dependent Functions 17 8 2 Disassembly 17 8 3 Maintenance 17 8 3 1 Cleaning 17 8 3 2 Replacing a Collision Sensor 17 8 4 Troubleshoo...

Страница 5: ...rchase and full payment of the product all text and images in Chapter 2 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user documentat...

Страница 6: ...lly Height Adjustable Tables It is installed by Resellers into Height Adjustable Table systems It is used to recognize collisions between the Table System and other objects It is intended for indoor u...

Страница 7: ...es INFO Indicates important tips for handling the product 2 6 LIABILITY LOGICDATA products comply with all currently applicable health and safety regulations However risk can result from incorrect ope...

Страница 8: ...lision Sensor in potentially explosive atmospheres CAUTION Risk of minor or moderate injury through tripping During the assembly process you may have to step over Cables Tripping over Cables may lead...

Страница 9: ...ctions that end users require to handle the product safely They must also include an instruction to always keep the Operating Manual in the immediate vicinity of the product INFO No unauthorized perso...

Страница 10: ...ing the ISP function ISP sensitivity and ISP shutdown values depend on the complete system mechanical and electronic components Contact LOGICDATA to determine the ISP suitability of your Table System...

Страница 11: ...op 30 0 mm 1 181 Fig 1 Product dimensions ACS CB SENS 5 4 DIMENSIONS LOG PRT DMS Length 48 3 mm 1 902 Width 31 8 mm 1 252 Height to underside of Table Top 29 0 mm 1 142 Fig 2 Product dimensions LOG PR...

Страница 12: ...generally accepted standards and guidelines of electrical engineering and furniture manufacturing Read all instructions and safety advice carefully CAUTION Risk of minor or moderate injury through tr...

Страница 13: ...prod uct s datasheet 6 4 MOUNTING THE ACS CB SENS NOTICE Ensure the ACS CB SENS is mounted in a place from which the cables can easily reach the Control Box and LOG PRT DMS Sensor Stretching or strain...

Страница 14: ...fications INFO LOGICDATA recommends a tightening torque of 3 Nm for the connection to the Crossbar and 2 2 5 Nm for the connection to the table top depending on material used 1 Place the surface of th...

Страница 15: ...the specific function or circuit characteristic the connector or terminal is used for INFO If your system is not parametrized to support Intelligent System Protection you will need to alter the parame...

Страница 16: ...e ACS CB SENS Fig 6 3 Insert the cranked 8 pin cable into the Port on the top of the Control Box Fig 7 4 Reconnect the Control Box to the power source Fig 6 Connecting the LOG CBL CB SENS to the ACS C...

Страница 17: ...nauthorized spare or accessory parts may cause system damage Warranty claims are void in this scenario 8 3 1 CLEANING 1 Disconnect the Control Box or DYNAMIC MOTION system from the mains 2 Wait 30 sec...

Страница 18: ...rk 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc 5300 Broadmoor Ave SE Suite...

Отзывы: