background image

Sentry Manual  Rev2.1 

Copyright 2017,  Nellis Engineering, Inc. 

3

Installation 

 

The  internal  transmitter  is  held  in  place  inside  the  DPV  with  adhesive  hook  and  loop  faster  tabs 
stuck on the inside wall.  There is an attachment placement on the top inside wall of the tube, for 
the  transmitter  antenna  and  an  attachment  placement  on  the  bottom  inside  wall  for  the  water 
detector and reed power switch.  Clean the inner diameter with alcohol or acetone if necessary, so 
the adhesive will stick. The long Velcro strip containing the antenna of the transmitter should be 
positioned as shown, approximately 2-3 inches from the rear edge of the tube. Peel off the backing 
of the three short pieces of hook material, to expose the adhesive, and affix it to the upper inside 
wall of the tube in an arc as shown in (Fig. 1)  Two outer pieces of hook strip attached to the inside 
wall to support the each end of the antenna will require removal if the batteries ever need to be 
removed from the body. 
 
For  the  water  detector,  measure  1.3”  into  the  tube  at  the  bottom  from  the  opening  edge  and 
place  a  temporary  mark  with  a  pencil  or  piece  of  tape.    Ensure  the  two  short  hook  tabs  are 
attached to the water detector loop strip, peel off the backing of both hook sections to expose the 
adhesive and affix it to the bottom inside wall with the wire exiting to the left, so the hook tabs 
will not interfere with battery removal, (Fig. 2) The rear edge of the hook tab should be at the 1.3” 
mark  and  the  water  detector  further  inside.  This  will  place  the  reed  switch  used  to  turn  on  the 
transmitter, 2.3” from the tube opening.  The wires should exit to the left as shown. 
 

  

 

   Fig. 1 

 

 

 

 

 

       Fig. 2 

 

Place a mark on the outside of the tube 2.3” from the end of the tube and directly outside the wall 
from the water detection board. (FIG. 3)  Wrap the mounting strap for the Sentry external display 
around the tube.  Pass the end of the strap through the bungee loop and pull it back, stretching 
the  bungee  and  affixing  the  hook  and  loop  faster  together.    Position  the  strap  so  that  the  gray 
block  that  slides  on  the  bungee,  stops  against  the  strap  and  over  the  mark,  which  is  directly 
outside  the  tube  from  the  water detection  board.    The  gray  block  contains  a  magnet  to  activate 

1.3” 

Содержание SENTURY

Страница 1: ...Sentry Manual Rev2 1 Copyright 2017 Nellis Engineering Inc SENtry SENtry SENtry SENtry DPV Dashboard Installation and Operator s Manual...

Страница 2: ...supplied charger WARNING Do not leave the batteries alone or installed in DPV in direct sunlight or a hot car Temperatures of 160 F 70 C or above can damage the batteries resulting in fire or explosio...

Страница 3: ...1 3 into the tube at the bottom from the opening edge and place a temporary mark with a pencil or piece of tape Ensure the two short hook tabs are attached to the water detector loop strip peel off t...

Страница 4: ...how you turn off the transmitter when not in use This will position the display about 2 0 from the end of the tube as well If reception is intermittent position the display as far towards the rear as...

Страница 5: ...r housing off of the white connector housing and wrap the label with the 2 on each end around the yellow wire of this battery as shown in Fig 7 Connect the red wire from Battery 2 to the short lead co...

Страница 6: ...or positioning the display In air and fresh water the display should have 10 bar most of the time but in salt water the RF signal is attenuated and fewer bars may be displayed If the bars are blinking...

Страница 7: ...power that the motor is currently using in real time The diver can control the DPV to limit the power to that is required by the dive plan By referencing a known distance over a time period the diver...

Страница 8: ...is detected inside the DPV the display screen which is normally black background with yellow lettering will flash alternately to yellow background with black lettering and H2O display left and right o...

Страница 9: ...nutes outbound multiplied by 180 ft min equal 8100ft or 1 5 miles of range 5280ft mile Battery Life Calculation As batteries age they lose capacity and become less safe due chemical to changes inside...

Страница 10: ...ansmitter unit is not covered under this warranty 3 The battery charger is not covered for water damage 4 Structural or cosmetic damage from abuse or corrosion is not covered 5 Nellis Engineering Inc...