Appendix C
–
Device Configuration Guide
Please refer to Appendix A to get inside access to the device.
The RTCU LX5 eco has many features, and some of them require configuration by using hardware
jumpers located inside the device. The placement of the jumpers are as follows:
Feature
Jumper
State
Default state
Communication
RS485 T.
Installed
Not installed
RS485 line 120 Ω resistor enabled
RS485 line 120 Ω resistor disabled
CAN T.
Installed
Not installed
CAN bus line 120 Ω resistor enabled
CAN bus line 120 Ω resistor disabled
CAN WE
Installed
Not installed
CAN bus write-enabled
CAN bus write disabled
RS485 line
termination
CAN bus
line termination
CAN bus
write enable