Logic Controls, Inc.
SYSTEM SETUP
1 Install the LS6000 units as described in HARDWARE INSTALLATION
section.
2 Setup optional LS6000 parameters if necessary (for example, RS232
baud rate and beeper pitch).
3 Setup the station address used for quick identification of the station.
4 Setup IP address, subnet mask and port number to the required values.
Check with system administrator for proper settings. Note that the IP
address must match the IP group of the host server and the TCP port
address must match the port number used by the application software.
5. Save parameters and exit setup.
6 Verify that the values on the boot up screen shows the correct set up
values. If not, repeat step 2 to 5 to correct the settings.
7 You have now completed the setup for one LS6000. Repeat as
necessary for each LS6000 in the system, ensuring a unique IP address
for each LS6000. Always verify your setting on the boot up screen.
8. Setup the host server IP address such that it’s in the same IP group as
the LS6000 units.
9. Setup the application software if necessary.
10. Run the application software or a test program to verify functions of the
system.
GENERAL SPECIFICATIONS
MECHANICAL
Weight
2.25lbs
Dimension (in Inches)
6.3W x 1.0H x 5.1D
ELECTRICAL (Power Adapter)
Input voltage
100 to 240VAC
Input frequency
47 to 63 Hz
Input power
30VA max
Output voltage
+5VDC
Output current
1A max
Ripple voltage
< 100mVp-p
ENVIRONMENT
Operating temperature
5ºC to 40ºC
Relative humidity
8 to 80%
Storage temperature
0ºC to 60ºC
Relative humidity
5 to 80%
INTERFACE
To host server
Ethernet 10BaseT
VGA Port
Standard VGA
Keyboard
PS2
Serial Port
RS232C
Baud Rate
2400, 4800, 9600, 19200
Parity
None
Data Bits
8
CABLES
General
Connectors are latched or
with strain relief
Ethernet
8 pin modular RJ45 male
RS232
Standard
DB9 female
VGA
Standard high density
DB15 male
Keyboard
6 pin modular RJ11 male