background image

11

DRAWER GUARD

You can fix up your special
drawer using some aluminium
foil as shown.  If the drawer is
opened the aluminium foil will
brush past the two metal ends
of the Jack Plug wires so 
completing the circuit and 
setting the alarm off. 

Hide the Logiblocs at the back or beside the drawer where there is usually 
a bit of space.

CHECK FOR METAL!

We can use the two metal ends of the Jack
Plug Wires to test for metal. Metal conducts
electricity and so you can test all sorts of
objects. Use the same Logibloc arrangement
shown on the opposite page. Test a pencil.
Does the lead inside conduct electricity? So
it’s not just metal that conducts electricity.

Remember not to put these wires anywhere
near any mains electrical outlets because that
could be very dangerous.

SOME MORE EXPERIMENTS

Now you have made some models that work, let's go one step further and
make a Drawer Guard and a Metal Detector.

Step 4

Hold the two wires in each hand and touch the metal 
ends of the two wires together.

The LIGHT on the CROSS will light up. If not, check 
that you have followed the instructions correctly so far.

If you still have trouble, check that your battery isn’t flat!

Step 5

Now add the STRAIGHT and 
the BLEEP and touch the two wires 
together again. The LIGHT and 
the BLEEP should now come on.

Step 6

Add  the DELAY.  This will  light up 
and when you separate the Jack Plug
wires the DELAY will stay on for about
10 seconds before going off 
automatically.

BLEEP

STRAIGHT

6

You have successfully completed the test procedure.   Well done !

Now it is time to make some model sensors and 

let the Logiblocs get to work !

DELAY

Содержание Alarm Kit

Страница 1: ... a registered trademark of Logiblocs Limited 2002 Logiblocs Limited All rights reserved VERSION 180602 1001 We welcome your comments or questions about our products or service WRITE TO Logiblocs Limited PO Box 375 St Albans Herts AL1 3GA UK E MAIL service logiblocs com VISIT OUR WEBSITE www logiblocs com ...

Страница 2: ...d the section on safety at the end of this booklet Do not use the Logiblocs until you understand the safety advice Please keep these instructions for future reference Never ever touch or try to push any wires into a mains electrical socket or plug This would be very dangerous Do not let the Logiblocs get wet and never put any parts or wires into your mouth LOOKING AFTER YOUR LOGIBLOCS It s a good ...

Страница 3: ...the connectors Do not place the Logiblocs themselves in water CONNECTORS 14 UNDERSTANDING LOGIBLOCS Logiblocs make computer technology simple Logiblocs is the electronic discovery system that helps you understand about the world of technology around you as you create your own inventions From traffic lights to super computers everything in today s high tech world runs by the same principles that Lo...

Страница 4: ...ts up whenever it receives a signal and it passes it on immediately IN When the two wires of the Jack Plug are joined together the IN block triggers any other block that is connected to it BLEEP When a signal gets to the BLEEP it makes a noise 13 CONTENTS Please check that you have all the parts in the Alarm Kit as follows BATTERY CONNECTOR STRAIGHT CROSS IN DELAY BLEEP JACK PLUG PRESSURE MAT CARD...

Страница 5: ...nswer put one or two fingers from your other hand onto the second pad The sound level of the BLEEP will change depending on how hard you press or how much your hands are sweating because of telling lies You can also do this with two people Put your right hand on the right pad while your friend puts his or her left hand on the left pad Ask each other questions and then join your free hands together...

Страница 6: ...any mains electrical outlets because that could be very dangerous SOME MORE EXPERIMENTS Now you have made some models that work let s go one step further and make a Drawer Guard and a Metal Detector Step 4 Hold the two wires in each hand and touch the metal ends of the two wires together The LIGHT on the CROSS will light up If not check that you have followed the instructions correctly so far If y...

Страница 7: ...let water trigger the Logiblocs Fix the sheets to the side of the bath to warn you when the water has reached the right level 10 LET S GET THE LOGIBLOCS TO WORK As you have seen joining the ends of the two wires of the Jack Plug can trigger the Logiblocs into action Joining the wires together is called completing the circuit There are lots of different ways that you can complete the circuit which ...

Страница 8: ...mat just to give a short beep then remove the DELAY from the system Remember to disconnect the battery when you are not using the Logiblocs to save the battery 9 Step 3 Shape a strip of aluminium foil around the edge of the door itself at the height of the two wires When the door opens the aluminium foil will touch both wires which should trigger the Logiblocs into action This is called completing...

Отзывы: