background image

7-IN-1 WIRELESS 

WEATHER STATION 

LOWSC710B

Содержание LOWSC710B

Страница 1: ...7 IN 1 WIRELESS WEATHER STATION LOWSC710B ...

Страница 2: ...rections before using the product and retain this guide for reference This product is intended for household use only It is not intended for commercial use This product is covered by a limited one year warranty Coverage is subject to limits and exclusions See warranty for details SAFETY PRECAUTIONS 3 PRODUCT FEATURES 4 PACKAGE CONTENTS 4 PRODUCT OVERVIEW 5 7 INSTALLATION INSTRUCTIONS 8 10 OPERATIN...

Страница 3: ... the product with a soft cloth if liquid spills on it Do not subject the unit to excessive force shock dust extreme temperature or humidity Do not cover or block the ventilation holes with any objects The console of this product is intended to be used indoors only This product is only suitable for mounting at height less than 6 6 ft 2 m Do not tamper with the unit s internal components Tampering w...

Страница 4: ... rainfall UV index light intensity temperature and humidity No calibration needed The product is fully pre calibrated and mostly assembled all you need to do is install it and sync with the included display console Provides precise weather and environmental information directly from your own backyard instead of relying on a national weather station Color LCD display with dimmable backlight Can ale...

Страница 5: ...ND button 9 BARO button 10 LCD display 11 CLOCK button 12 ALARM button 13 Wall mounting holder 14 ALERT button 15 DOWN button 16 UP button 17 Power cord 18 C F button 19 SENSOR button 20 RCC button 21 Battery compartment 22 OFF LO HI slider 23 RESET button DC5V 600mA SENSOR RESET RCC MAX MIN HISTORY CHANNEL 1 2 3 6 4 7 5 8 9 10 19 11 20 21 22 23 12 13 14 15 16 17 18 ...

Страница 6: ...PLAY OVERVIEW 1 Time date moon phase 2 Outdoor temperature humidity 3 UV index light intensity 4 Rainfall rain rate 5 Indoor temperature humidity 6 Barometer weather forecast 7 Wind direction speed 1 5 2 6 3 7 4 ...

Страница 7: ...5 16 1 Antenna 2 Rain collector 3 UVI light sensor 4 Mounting pole 5 Mounting base 6 Balance indicator 7 Wind cup 8 Radiation shield 9 Wind vane 10 Red LED indicator 11 RESET button 12 Battery compartment 13 Mounting clamp 14 Rain sensor 15 Tipping bucket 16 Drain holes ...

Страница 8: ...ding to the polarity labeled in the compartment 3 Screw the battery door back onto the compartment NOTE The LED light will flash red every 12 seconds Mounting the Sensor on Pole 1 Pick a location for the 7 in 1 outdoor sensor that s open with no obstructions 2 Place the outdoor sensor over the top side of the mounting pole included Make sure the square holes are aligned with each other 3 Insert th...

Страница 9: ...he mounting base 7 Place the mounting base onto a post and place the mounting clamp on the other side of the post 8 Align the holes of the mounting base and mounting clamp then tighten the two together using four 4 included screws washers and hexagonal nuts NOTES Place the mounting base and clamp on a steel pole or post with a 1 1 3 25 33 mm diameter and is a minimum of 4 9 1 5 m off the ground Wh...

Страница 10: ...ers on it should automatically search for and connect to the wireless weather sensor If the console does not connect within the first 15 minutes refer to the following section Changing Batteries and Manual Pairing of Sensor for instructions on manual pairing 2 Once the pairing process is complete the antenna icon will appear solid not blinking and the readings for outdoor temperature humidity wind...

Страница 11: ... and the 12 24 hr symbol will begin to flash 2 Press the UP or DOWN button to adjust the time zone 3 Press the CLOCK button again to proceed to the next setting 4 Settings will cycle through the following options Time Zone Hour Minute Second Year Month Day Hour offset Weekday language DST AUTO OFF 5 Press the CLOCK button one final time after adjusting all settings options to save and exit or the ...

Страница 12: ...RM button to display the set alarm time for five 5 seconds 2 When the alarm time is being shown on the LCD display press the ALARM button again to cycle through the alarm functions Alarm off Alarm on Temperature Pre alarm as shown below The corresponding icons will appear on the LCD display 3 To stop the alarm a Allow the alarm to continue for two minutes and it will stop itself automatically It w...

Страница 13: ... indicator 2 Comfort indication 3 Temperature alert indicator 4 Humidity trend 5 Humidity reading 6 Temperature trend 7 Temperature reading 1 7 8 9 10 2 3 4 5 6 1 4 5 6 7 2 3 Trend Indicator Press the C F button to switch between Celsius and Fahrenheit temperature measurements The arrows show the trend in changes to the temperature humidity levels Indoor Comfort Indicator The indoor comfort indica...

Страница 14: ... you can press the CHANNEL button once to toggle auto cycle mode off and continue displaying the current channel BAROMETRIC PRESSURE WEATHER FORECAST Weather Forecast The built in barometer can notice atmospheric pressure changes and based on the data collected can predict the weather conditions in the forthcoming 12 24 hours within a 19 31 mile 30 50 km radius View the chart below to see what eac...

Страница 15: ...d hold the BARO button for two 2 seconds to enter the unit setting mode 2 Press the UP or DOWN button to change the unit between inHg mmHg hPa 3 Press the BARO button again to enter the relative pressure value setting mode 4 Press the UP or DOWN button to change the relative pressure value 5 Press the BARO button to save settings and go back to ABS or REL mode that you selected before NOTES When p...

Страница 16: ...l between mm and in 3 Press the RAIN button again to confirm and exit Reset the Rainfall Records While in normal operating mode press and hold the HISTORY button for eight 8 seconds to reset the rainfall records NOTE To ensure precise data please reset the rainfall records whenever you move and reinstall your wireless weather sensor to a different location WIND 1 2 3 4 5 6 7 8 1 Wind direction rea...

Страница 17: ... to confirm and return to normal display mode 4 Press the WIND button while in normal operating mode to enter wind direction display mode 5 Press the UP or DOWN button to toggle between 360 degrees or 16 direction mode 6 Press WIND button again to confirm and exit settings The wind speed level chart on display provides a quick reference on the current wind condition Level LIGHT MODERATE STRONG STO...

Страница 18: ...ructures Debris and unsecured objects are hurled about 10 Trees are broken off or uprooted structural damage likely 11 Widespread vegetation and structural damage likely 12 Light breeze Gentle breeze Moderate breeze Fresh breeze Strong breeze High wind Gale Strong gale Storm Violent storm Hurricane force 6 11 km h 4 7 mph 4 6 knots 1 6 3 3 m s 12 19 km h 8 12 mph 7 10 knots 3 4 5 4 m s 20 28 km h ...

Страница 19: ...ton to confirm and exit the setting NOTE The light intensity function is for sunlight detection Feels Like The Feels Like temperature index determines what temperature it actually feels like outside taking into account factors like wind chill and the heat index Heat Index The heat index is determined by the wireless weather sensor s temperature and humidity readings when the temperature outdoors i...

Страница 20: ... the UP or DOWN button to adjust the UV gain value Default is 1 0 3 Press the INDEX button again to enter the light intensity calibration mode 4 Press the UP or DOWN button to adjust the light intensity gain value Default is 1 0 5 Press the INDEX button to exit calibration HISTORY History Data for Past 24 Hours The display console automatically stores the weather data from the past 24 hours 1 Pres...

Страница 21: ...ht intensity Records are displayed in the following order when the CH 1 2 or 3 temperature humidity is shown Indoor MAX temperature indoor MIN temperature indoor MAX humidity indoor MIN humidity MAX pressure MIN pressure CH MAX temperature CH MIN temperature CH MAX humidity CH MIN humidity Reset the Total MAX MIN Records Press and hold the MAX MIN button for two 2 seconds to reset the MAX MIN reco...

Страница 22: ...pe the selected value will flash then press the UP or DOWN button to adjust the value or press and hold the button to change the value rapidly 5 Press the ALARM button to toggle the alert on or off 6 Press the ALERT button to confirm the setting and move to the next alert reading 7 When finished press and hold the ALERT button for two 2 seconds to exit the alert setting Silence the Weather Alert A...

Страница 23: ... signal Weak signal Signal lost POINTING THE 7 IN 1 SENSOR TO THE SOUTH The outdoor 7 in 1 sensor is calibrated to be pointing to the North by default However in some cases users may wish to install this sensor point to the South 1 Install the outdoor 7 in 1 sensor with its arrow pointing to the South 2 On the console press and hold the WIND button for eight 8 seconds until the upper part Northern...

Страница 24: ...eather sensor s are running low and should be replaced Make sure to replace all batteries at the same time REPLACING THE WIND CUP 1 Remove the rubber cup and unscrew the wind cups 2 Remove the wind cups for the new replacement REPLACING THE WIND VANE 1 Unscrew and remove the wind vane for the new replacement CLEANING THE RAIN COLLECTOR 1 Unscrew the rain collector by turning the rain collector cou...

Страница 25: ...r cloth Over time the UV sensor will naturally degrade The UV sensor can be calibrated with a utility grade UV meter CLEANING THE HYGRO THERMO SENSOR 1 Remove the two 2 screws at the bottom of the radiation shield 2 Gently remove the shield 3 Carefully remove any dirt or insects on the sensor fan do not let the sensors inside get wet 4 Clean the shield with water to remove any dirt or insects 5 In...

Страница 26: ...iation shield Check the sensor casing No data or measurement coming in for wind speed or direction Check the wind cups Check the wind vane If one of these symbols or appear the signal on your console has been lost Relocate the console and outdoor sensor making sure the two are close together Make sure the console is away from other electronic appliances ex TVs computers microwaves in your home Res...

Страница 27: ...OCK SPECIFICATIONS Synchronization Auto or disabled Clock display HH MM SS weekday Hour format 12hr AM PM or 24hr Calendar MM DD Weekday in 7 languages EN FR DE ES IT NL RU RCC time signal WWVB Time zone PST MST CST EST AST NST DST Auto off INDOOR BAROMETER SPECIFICATIONS Barometer unit hPa inHg mmHg Measuring range 540 1100 hPa Accuracy 700 1100 hPa 5 hPa 540 696 hPa 8 hPa 20 67 32 48 inHg 0 15 i...

Страница 28: ...x H x D 13 5 x 15 5 x 5 4 343 5 x 393 5 x 136 mm installed on mount Weight 1 7 lbs 757 g with batteries Main power 3 x AA 1 5 V batteries lithium batteries recommended Weather data Temperature humidity wind speed wind direction rainfall UV light intensity RF transmission range Up to 492 ft 150 m RF frequency 915 MHz Transmission interval Every 12 seconds Location use for sensor Outdoor use Adult a...

Страница 29: ... 5 m s 6 Memory modes Historical data of past 24 hours MAX Wind direction 16 directions or 360 degrees RAIN DISPLAY FUNCTION SPECIFICATIONS Rainfall unit mm and in Accuracy for rainfall 7 Range for rainfall 0 393 7 0 9999 mm Resolution 0 0157 0 4 mm Memory modes Historical data of past 24 hours MAX UV INDEX DISPLAY AND FUNCTION SPECIFICATIONS Display range 0 16 Resolution 0 1 Memory modes Historic...

Страница 30: ...ect at no charge using new or refurbished replacement parts 2 exchange the Product with a Product that is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original device or 3 refund the purchase price of the Product A replacement Product or part thereof shall enjoy the warranty of the original Product for the remainder of the War...

Страница 31: ...CLAIM ALL WARRANTIES AND CONDITIONS WHETHER EXPRESSED IMPLIED OR STATUTORY INCLUDING THE WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE TITLE QUIET ENJOYMENT ACCURACY AND NON INFRINGEMENT OF THIRD PARTY RIGHTS THE COMPANY DOES NOT GUARANTEE ANY SPECIFIC RESULTS FROM THE USE OF THE PRODUCT OR THAT THE COMPANY WILL CONTINUE TO OFFER OR MAKE AVAILABLE THE PRODUCT FOR ANY PARTICULAR LE...

Страница 32: ...ompany names and logos are trademarks of their respective owners used merely to identify their respective products and are not meant to connote any sponsorship endorsement or approval Distributed by C A Marketing Inc 114 Tived Lane East Edison NJ 08837 Made in China 2021 C A IP Holdings LLC All Rights Reserved ...

Отзывы: