background image

Introductions

Congratulations on your purchase of the TeleDoorBell, a system that offers enhanced security while providing 
unparalleled convenience. The system can be used with or without a doorbell.
Operation is subject to the following Conditions:
1) This device may not cause harmful interference
2) This device may accept any interference including interference that may cause undesired operation.
Complies with Part 68, FCC Rules FCC REG NO.  5ERCAN-31264-OT-N   REN: 0.8B
(DOC/CSA/UL approved)

Features

The TeleDoorBell is a telephone based doorbell system that provides the system user with the capability of 
communicating with a door speaker from any installed telephone set, including cordless.  Unmatched in convenience, this 
unique new product provides the following features:

* System will work as a replacement or in parallel with any standard doorbell.
* Provides high-quality audio conversation capability with any connected door speaker.
* Unique telephone ringing when door speaker button depressed. 
* Allows homeowner to select the door speaker by entering a unique touch-tone code from any telephone.
* Will provide toll restriction at the discretion of the owner.
* Rings telephones distinctively when door speaker button depressed.
* Relay closure to ring doorbell or a number of other devices.
* Can be set to ring doorbell only.
* Door speaker has LEDs for constant illumination.
* Supports speakerphone quality conversation between the telephone and the door speaker.
* The system gives a user two minutes to access door following the depression of the door speaker button. 
* If the door speaker button is depressed, when the telephone is in use on an outside call, the user hears a beep 

tone to alert that there is a visitor at the door.  The user can then depress 

*4

 on a touch-tone telephone to put the 

telephone call on hold and connect to the door speaker. Depressing 

*4

 again will return to the telephone call.  

Note: this can only be used once and only after the door speaker button is depressed.   Alternatively, a user can 
hang up on the telephone call and then pick up the handset and they will be connected to the door speaker.  (This 

needs to be done within the two minute window.   #   can be used beyond the two minutes).

* *

* A DTMF code selection (dialed from any connected telephone) allows the system user to access the door speaker 

outside of the two-minute window.

* Relay closure activated by DTMF digit 

*5

 or 

*8

  allows door strike dry contact operation. (Normally Open NO).

* Toll Restriction, 1+ long distance, 011 international, or 1+976, user programmable.
* Password protection for programming which user can change to a personal 3-digit DTMF code.
* Progress tones to guide user while programming.

Parts list

The TeleDoorBell system is shipped from the factory with the following components:

* TeleDoorBell control unit 
* Speaker Unit with wall mounting plate
* CSA/UL approved class 2 Power Supply, Input 120VAC, 60Hz, Output 16Vac 250 mA.  Note the system will also 

work with a class 2 Power Supply Input 120VAC, Output 16-24Vdc 350 mA.  Please make sure that the output 
does not exceed 24 VDC or serious damage may occur.

* Two (2) modular RJ-11 Male open-ended patch cord.  Used to splice and connect door speaker unit, door strike 

and doorbell, to the TeleDoorBell system unit. 

* RJ-45 8 pin male to male modular patch cord.
* Three (3) #6 wood screws for mounting
* Dimensions:  Controller (17cmX17cmX4cm)  Door-speaker (15.5cmX10.5cmX3cm)

Page 3

Содержание TeleDoorBell

Страница 1: ... info logenex com For complete information please visit our website at www logenex com Ri ngOn Off Relay Contacts Door Spkr 2 Door Spkr 1 TeleL ine In Out Power Plug TeleDoorBell Unit Don t open your door to the unknown TeleDoorB ell T M Ins tallation Manual Page 1 Revision 5 June 2003 ...

Страница 2: ...o dangerous voltages or other risks Incorrect re assembly can cause electric shock when the appliance is subsequently used 12 Unplug this product from the wall outlet and refer servicing to a qualified service personnel under the following conditions When the power supply cord or plug is damaged or frayed If liquid has been spilled into the product If the control unit has been exposed to rain or w...

Страница 3: ... depressed when the telephone is in use on an outside call the user hears a beep tone to alert that there is a visitor at the door The user can then depress 4 on a touch tone telephone to put the telephone call on hold and connect to the door speaker Depressing 4 again will return to the telephone call Note this can only be used once and only after the door speaker button is depressed Alternativel...

Страница 4: ...ete the installation the installer must supply the following RJ31X and or CA38A disconnect and bypass jack This is an optional device however it is recommended in the event that the unit needs to be disconnected This will provide a bypass capability whereby the telephone line continues to work if the TeleDoorBell unit needs to be removed from the telephone line Note If installation is done at a lo...

Страница 5: ... from wall 2 Thread wire through opening at bottom of unit Note We recommend that you use silicon sealer to protect the wiring around the hole 3 Hang The D 100 F speaker on initial mounting screw 4 Secure the D 100 F speaker to the wall with secondary mounting screw See Fig 3 5 Connect the four wires to the wiring post of the D 100 F speaker See fig 4 6 Replace the wiring cover back on the speaker...

Страница 6: ...5 Modular Wire Supplied with Unit RJ11 Modular Wire Supplied with unit Use a 22 gauge 4 conductor wire Max Length 250 ft to connect from controller to speaker OUT OUT IN IN RJ31X CA38A Alarm Jack TELCO IN LINE from phone company Alarm jack connection only if alarm monitored PRESS This contact is activated by pressing door speaker button To Door Strike or any activation device PRESS Red Yellow Grey...

Страница 7: ...ing wire if being used cannot be daisy chained or be transmitting any other voice or data information other than the internet connection make sure that you install a Data Filter on the Voice Line to block out any of The high frequency noise Existing Phones on premise High Speed Phone Line Internet Ring On Off Relay Contacts Door Spkr 2 Door Spkr 1 Tele Line In Out Power Plug TeleDoorBell Unit OUT ...

Страница 8: ...or at the controller 2 The Red and Black wires may be reversed either at the speaker or at the controller 1 Your ringer switch located at the front of the controller may be set to the OFF position 2 The Yellow wire is not properly connected to either the speaker or the controller section of the speaker 3 One of the phones may be causing to much of a load unplug all phones and begin testing with on...

Страница 9: ...ion of the product PPAL Industries Ltd 19 Kenview Blvd Unit 31 Brampton Ontario L6T 5G6 CANADA Phone 905 790 8823 or 1 888 790 5900 Fax 905 595 1159 Email info ppalindustries com WARRANTY User Manual Customers Copy Page 1 of 1 How to use your TeleDoorBell TM 1 If your doorbell rings or you hear the unique TeleDoorBell ring signal pick up any telephone in the house within two minutes You can now ta...

Страница 10: ...6A 7500 Martin Grove Rd Woodbridge ON Canada L4L 8S9 Toll Free 1 888 790 5900 E mail info logenex com For complete information please visit our website at www logenex com ...

Отзывы: