![Loft Centre Caernarvon 400 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/loft-centre/caernarvon-400/caernarvon-400_fitting-instructions-manual_1934297003.webp)
Check Opening Dimensions:
The sliding stairway will work with most ceiling thicknesses from
160mm. If the ceiling thickness is greater han 355mm, please
call for additional instructions. Please refer to
Fig.2
and
Table 2
to check that the size of the rough and finished openings are
correct for your specific model.
Model
Rough
Opening
Inside Dim.
Finish
Opening
Inside Dim.
Guide Frame
Slide Bar
Inside Width
400 Size 1-4
660 x
1727mm
611 x
1680mm
422mm
400 Size 5-7
660 x
1879mm
611 x
1830mm
422mm
700 Size 1-4
812 x
1727mm
764 x
1680mm
468mm
700 Size 5-7
812 x
1879mm
764 x
1830mm
468mm
Table 2
Fig.2
Fig.1
Check Model Size:
Be sure to check the
storage height
(C) and
storage length
(B) above the handrail. Please refer to
Fig.1
and
Table 1
to
ensure that the size of your specific model fits within the
specified requirements.
Size
(A)
Floor to
Floor (mm)
(B)
Radius
Height
(mm)
(C)
Storage
Height
(mm)
(D)
Going
(mm)
1
2311 to
2412
1244
889
1625
2
2413 to
2564
1422
1041
1727
3
2565 to
2717
1600
1193
1828
4
2718 to
2869
1778
1346
1930
5
2870 to
3021
1778
1371
2032
6
3022 to
3174
1981
1549
2108
7
3175 to
3302
2159
1651
2235
Table 1
BEFORE YOU INSTALL THE LADDER
PLEASE CHECK ALL PARTS BEFORE COMENCING CONSTRUCTION
You should have
three
parcels:
1 - Contains the hardware, fittings, instructions and treads
2 - Door predrilled for door guide frame and screw eye
3 - Strings and handrail with uprights
Check Guide Frame Slide Bars
Check
header guide frame
and
door guide
frame slide-bars
for alignment. The Model 400
should be 422mm across the inside of the side
bars and parallel. The 700 should be 468mm
across. You may adjust the slide bars by bending
the brackets slightly in or out as needed.
Door Guide Frame
Header Guide Frame
Slide Bar
s
3
Содержание Caernarvon 400
Страница 1: ...Caernarvon 400 700 Fitting Instructions 1...