750 Control Panel Operation and Troubleshooting
463-3000-08 revised Sept 16, 2013
21
Warm Up s
Selects the number of seconds to operate at idle
speed before beginning the ramp to intermediate
speed. The warm up time begins when the starter is
disengaged.
Ramp Up s
Selects the number of seconds to ramp from idle
speed to intermediate speed after warm-up
Intermediate s
Selects the number of seconds to operate at
intermediate speed before ramping to run speed
Ramp to Run s
Selects the number of seconds to ramp from
intermediate speed to run speed after intermediate
warm-up
Ramp Down s
Selects the number of seconds to ramp from current
speed to idle speed. The ramp down time begins
when the automatic start/stop system detects a stop
event.
Cool Down m
Selects the number of minutes to operate at idle
speed after ramp down time. At the end of the cool
down period the engine will be stopped.
Servo
Configures the servo profile for autostart maintain
modes
Gain
Controls the aggressiveness of the maintain servo
modes.
Delay 10mS
Controls how quickly the maintain servo mode
responds to changes in level.
Transducer
This submenu configures the transducer type and set
points.
Type
Selects between
Level
and
Pressure
Range
Selects appropriate range for the transducer type
High Set Point
For
Empty
and
Maintain Out
modes, sets the level
that
begins
an autostart cycle. For
Fill
and
Maintain
In
modes sets the level that
ends
the cycle.
Maintain Point
Sets the target point for maintain modes
Low Set Point
For
Empty
and
Maintain Out
modes sets the level
that
ends
an autostart cycle. For
Fill
and
Maintain In
modes sets the level that
begins
a cycle.
Dead Band
Sets the amount of change from the target point
required to alter the engine speed.
Starter
This submenu configures starter control options for
autostart
Restart Attempts
Selects the number of times to attempt restart
Restart Delay Sec
Selects the number of seconds to wait before
attempting a restart