750 Control Panel
Operation and Troubleshooting
463-3000-08 revised – Sept 16, 2013 CANplus and CANplus logo are registered trademarks of LOFA Industries, Inc.CP750 and the LOFA logo are trademarks of LOFA Industries, Inc.
Страница 1: ...rol Panel Operation and Troubleshooting 463 3000 08 revised Sept 16 2013 CANplus and CANplus logo are registered trademarks of LOFA Industries Inc CP750 and the LOFA logo are trademarks of LOFA Indust...
Страница 2: ...components of any safety device or system that is intended to prevent bodily injury protect life or prevent property damage The specifying Original Equipment Manufacturer OEM and or Installer of any...
Страница 3: ...ult in the automatic starting and stopping of the engine machine The engine machine as a function of the emissions system can could initiate via the engine ECU certain required emissions operations su...
Страница 4: ...imers The CP750 display provides sixteen 16 service timers to alert the operator of needed maintenance The time interval for each timer can be adjusted in 10 hour increments A popup message is display...
Страница 5: ...arious other parameters such as the full scale reading of gauges Four bright LEDs below the display indicate Auto Standby Preheat Stop and Warning status Five buttons access a context dependent button...
Страница 6: ...and engine conditions After waiting for the Preheat LED to extinguish the engine is cranked by turning and holding the key switch in the start position until the engine starts Note The ECU will not p...
Страница 7: ...turtle icon requests the engine to go to Idle RPM Digital Rotary Throttle The optional Digital Rotary Throttle uses a rotary switch to simulate the operation of a throttle potentiometer Like the Ramp...
Страница 8: ...selected mode to reduce the level or pressure Fill Uses the selected mode to increase the level or pressure Maintain Out Uses the transducer to maintain the level or pressure at or below the target M...
Страница 9: ...t point For example if the target is 5 0 feet with a 0 1 foot dead band the dead band is 4 9 to 5 1 feet CANplus Display Soft buttons simplify the user interface by displaying a button bar above the b...
Страница 10: ...by repeated pressing of button 2 The four standard gauge pages are shown below Page 1 Page 2 Page 3 Page 4 Note The 16 gauges are the same for Analog and Digital Gauge Pages Adjustments in either Ana...
Страница 11: ...te Only active faults are displayed in the alarm list Once a fault is corrected it is automatically removed from the list To view previously active faults use the engine diagnostic tool Configuration...
Страница 12: ...diately Some such as Idle RPM take effect on the next power up Display Menu The Display Menu allows the user to configure items affecting how information is displayed Units Menu This menu allows the u...
Страница 13: ...soft buttons emit an audible beep when this item is On Button beep is disabled by setting this item to Off The audible beep still sounds when an alarm occurs Button 4 cycles between On and Off Gauges...
Страница 14: ...time while Button 2 increases the service interval time in 10 hour increments Holding Button 3 for approximately 3 seconds resets Next Service In to the current service interval The service timer desc...
Страница 15: ...Pages Defaults Quad Adjust On Demo Mode 0 Off Engine Source 0 Display CAN Address 40 Alarm Filter Glb SPN Version 1 Speed Source Auto PIN Entry Off PIN 1111 Max Gauge RPM 2500 Max Gauge Speed 40 MPH...
Страница 16: ...ine configuration while button 1 selects the previous page J1939 Settings This screen allows adjustments specific to the J1939 data link Engine Source Selects which source the display listens to for g...
Страница 17: ...t your engine supplier to establish the appropriate SPN conversion method version Selecting the wrong version will causealarm data to be displayed incorrectly Speed Source There are 3 sources of speed...
Страница 18: ...adjusts the first digit of the PIN Button 2 adjusts the second digit button 3 the third digit and button 4 the fourth digit The PIN is entered using button 5 PIN Change This allows changing the PIN Th...
Страница 19: ...isplays the following product information ID Build Serial number of the display EEPROM Number of writes on EEPROM PART No Unit part number VERS Software version number CHK Flash memory checksum SOURCE...
Страница 20: ...optional two state or three state throttle switches Note The minimum engine speed is set by the ECU Requesting a lower speed causes the engine to run at the ECU minimum speed RPM limits are programmed...
Страница 21: ...will be stopped Servo Configures the servo profile for autostart maintain modes Gain Controls the aggressiveness of the maintain servo modes Delay 10mS Controls how quickly the maintain servo mode res...
Страница 22: ...e RPM The CANplus Configurator must be used to configure mechanical engine parameters CP750 CAN Add Selects the address used by the display to communicate with the CANplus I O board The default I O Bo...
Страница 23: ...e configuration or operation Aux Output Selects the Aux Output function and provides a 1 amp low side switch Running The output is active when the engine RPM exceeds 500 RPM AS Armed The output is act...
Страница 24: ...ved from the telemetry module Modem Type Identifies the modem type Cell Reg Identifies cell modem registration Cell State Indicates cell state and signal strength GPS Indicates GPS status RTC Indicate...
Страница 25: ...data The warning disappears and normal operation resumes once data is detected Note Incorrectly configuring the Engine Source address will result in no data available for display Data Not Available Ga...
Страница 26: ...Preheat LED Amber A solidly illuminated Preheat LED indicates the engine is preheating When the LED extinguishes the preheat period is complete and the engine may be cranked Note The CANplus only repo...
Страница 27: ...ic information regarding the exhaust emission system of your engine This information is maintenance procedural and safety related Failure to exactly follow the engine manufacturer instructions and sch...
Страница 28: ...RCE REGENERATION INHIBIT REGENERATION AUTO REGENERATION Regeneration of the emissions system is active and high exhaust temperatures are potential Engine performance MAY be affected The engine particu...
Страница 29: ...opology Most electronically governed engine installations include a harness with built in J1939 backbone Use twisted shielded pair with a drain wire for CANbus wiring terminated with 120 resistors at...
Страница 30: ...traps moisture in the connector and encourages corrosion Harness Routing The minimum routing radius of the wiring harnesses should be at least two times the diameter of the wiring harness Bends should...
Страница 31: ...or The control system provides switched positive battery protected by solid state MOSFETs These outputs include integral protection against overloads and short circuits An integral 40 AMP slow blow fu...
Страница 32: ...e must be followed if the component must be welded while installed on equipment with electronic controls This procedure will minimize the risk of component damage Warning Do not ground the welder to e...
Страница 33: ...CANplus display cannot show ECU parameters such as engine hours oil pressure and diagnostic codes This test procedure helps identify the problem location 1 Disconnect the battery Warning This test sh...
Страница 34: ...e 1 Data valid but below normal operational range 2 Data erratic intermittent or incorrect 3 Voltage above normal or shorted high 4 Voltage below normal or shorted low 5 Current below normal or open c...
Страница 35: ...Economy Trip Fuel Economy Trip Fuel Trip Fuel Rate Total Fuel Used Fuel Leakage 1 Fuel Leakage 2 Distance km Miles or Nmiles Distance Remaining Trip Distance Total Vehicle Distance Pressure kPa PSI or...
Страница 36: ...Speed Fan Speed Vehicle Speed Time h Total Engine Hours Trip Engine Hours Service Hours Miscellaneous Torque Converter Lock Up Engaged Transducer Current Gear Selected Gear CANTX Disable CANplus I O...
Страница 37: ...rientation creating a darker area NMEA National Marine Electronics Association serial communications protocol for marine use RS 232 Standard electrical interface for serial communications RS 485 Stand...
Страница 38: ...express written permission b This license is restricted to use with up to one 1 specific identified Licensee Devices additional devices or products from Licensee require additional licenses 4 Ownersh...
Страница 39: ...ces within its possession or control and C provide LOFA with a written statement certifying that it has complied with the foregoing obligations End use licenses to Licensee Devices for Customers grant...
Страница 40: ...ensee including by operation of law Transfer without the prior written consent of LOFA Any such transfer without the prior written consent of LOFA will be ineffective In any case any such Transfer abs...
Страница 41: ...463 3000 08 revised Sept 16 2013 41 This Page Intentionally Left Blank...
Страница 42: ...42 463 3000 08 revised May 23 2013 This Page Intentionally Left Blank...
Страница 43: ...463 3000 08 revised Sept 16 2013 43...