Maintenance
YarnMaster PRISMA
www.loepfe.com
33
5.1.2
Cleaning sensors
The sensor’s measurement channels must be cleaned regularly since contamination in the sensor area
can impair cleaning efficiency and can cause an increase in cuts and misclassifications.
Notes on cleaning sensors
Do not apply cleaning agents directly to the sensors!
Do not use sharp and hard objects for cleaning!
Do not immerse sensors in cleaning agents!
After the sensor's measurement channel has been cleaned, it is recommended to adjust
the spindle or group.
When using kerosene, antistatic oils, dyes and other chemical additives such as
poligomers or titanium dioxide, the sensor area must be cleaned at shorter intervals.
Prerequisite
ü
Cotton swabs are included.
ü
Sensing head cleaner is included.
1. Use dry or moistened cotton swabs with sensing head cleaner.
2. Insert the cotton swab with the cotton part into the measurement channel.
3. Pass the cotton swab through the measurement channel several times.
ð
The measurement channel is cleaned.
Содержание YarnMaster PRISMA
Страница 1: ...Operating instructions YarnMaster PRISMA 51318003_en Original manual Version 1 0 12 2021 ...
Страница 2: ......
Страница 4: ......