5.3 Parameter Setting Page
1.
Run Mode selection: Auto Timer, Continue
Auto Timer Mode: This mode of operation is used for dot or drop dispensing. Operator can
setup timer from 0~999s. the dispenser turns on with one press of the footswitch or input
start signal via from the service, the dispensing will begin immediately and continue until
the system times out.
Continue Mode: This mode of operation is used for the application of beads. Operator can
engage the footswitch(s) to start dispensing and hold until the dispensing cycle is complete.
When the footswitch is released, the dispensing will end immediately.
2.
Auto Timer: Set the dispensing time for
Channel A and Channel B in “Time” mode
.
3.
Reservoir Pressure setting
4.
Low Level Counter setting: Set the number of cycles that are permitted after low level is
detected. Once these cycles have elapsed, the system will not dispense.
5.
Pressure Unit selection: Bar/ Psi.
6.
More button
–
Enters calibration screen and password setting
See section 5.7
7.
Save Setting: Saves the changes.
1
2
3
4
5
6
7