background image

 

 

EQ RC30 Manual Reservoir 

IDH 2814022 

Operating Manual 

 

 

 
 
 
 
 
 

 

Содержание EQ RC30

Страница 1: ...1 EQ RC30 Manual Reservoir IDH 2814022 Operating Manual ...

Страница 2: ...ration 5 2 2 Operating Elements and Connections 5 3 Technical Data 6 4 Installation 7 4 1 Environmental and Operating Conditions 7 4 2 Connecting the Unit 8 4 3 Filling and Refilling the Product Reservoir 9 5 Operation 10 5 1 First Operation 10 5 2 Adjust the Level Sensor 11 6 Application Hints 13 7 Troubleshooting 13 8 Care and Maintenance 15 9 Accessories and Spare Parts 16 10 Diagrams 16 11 War...

Страница 3: ...ions are not observed the manufacturer can assume no responsibility Do not expose the connecting cable to heat oil or sharp edges Make sure the Unit stands stable and secure Use only original equipment replacement parts Always disconnect the power supply before servicing the unit Observe general safety regulations for the handling of chemicals such as Loctite adhesives and sealants Observe the man...

Страница 4: ...a 0 to 7 bar 0 100psi manual pressure regulator Easy to read pressure gauge Accommodates a variety of Loctite packages 1 6 Field of Application Intended use The Loctite EQ RC30 Manual Reservoir is suitable for the application of Loctite adhesive with a manual applicator at manual workstations such as in workshops laboratories and industrial installations It is possible to dispense anaerobic UV cur...

Страница 5: ... is equipped with a 0 to 7 bar 0 100psi pressure regulator that regulates the dispensing pressure of the reservoir Adhesive is fed from the reservoir to a manual dispense valve When the valve is actuated to open then adhesive flows through the outlet dispense needle The amount of product dispensed is controlled by four main factors Dispensing pressure set in the reservoir Length of time the dispen...

Страница 6: ...Pneumatic Connection P in 9 Low Level Connector XS2 10 Low Level Sensor 3 Technical Data Dimensions L x H x W 214x363x357 mm Total weight Kg lbs 3 5 8 Pneumatic Supply Clean dry air not to exceed 116 psi 8bar and filtered with a maximum of 10 micron Pneumatic hose size External dia 6mm Operating Temperature 10 C to 40 C 50 F to 104 F Storage Temperature 10 C to 60 C 14 F to 140 F ...

Страница 7: ...If any shipping damage is found DO NOT USE THE EQUIPMENT return it to your supplier immediately 4 1 Environmental and Operating Conditions Keep product feedline as short as possible The shorter the feedline the smaller the specific resistance and lower the dispensing pressure can be Avoid kinking of the feedline ...

Страница 8: ... Unit Use only the cable and hose sets supplied Connect the air pressure supply to reservoir P in 8 If connecting to an external controller connect the tank cord to the 9 pin D sub connector XS2 9 located on the rear panel of reservoir Insert feedline through the reservoir lid to the dimension shown below Alternatively use the reference line shown on the housing to set the feedline length Cut the ...

Страница 9: ...re loosening the reservoir locking knobs 6 the EQ RC30 Manual Reservoir must be depressurized pressure free When dispensing cyanoacrylate and an empty signal is shown refill the product reservoir immediately since air in the product line results in curing of the product The reservoir is depressurized when the depressurizing valve 2 is in OFF position and reservoir pressure gauge 3 indicates no pre...

Страница 10: ...dispensing pressure 5 Operation 5 1 First Operation Warning Before loosening the reservoir locking knobs 6 the EQ RC30 Manual Reservoir must be depressurized pressure free The EQ RC30 Manual Reservoir is depressurized when the reservoir pressure gauge indicates no pressure In any case Set the depressurizing valve 2 to position depressurize 5 1 1 Inserting the Product Bottle Follow procedure as des...

Страница 11: ...t of the valve 5 1 3 Adjusting the Dispensed Quantity If the dispensed flow is too slow or too fast On the pressure regulator 1 increase or decrease the dispensing pressure Open the dispensing valve to check the dispensed quantity Repeat the last two steps until the desired dispensed quantity is achieved If the desired dispensed quantity is not achieved Attach a larger or smaller dispensing needle...

Страница 12: ...e holder For 250ml product bottle pay attention to ensure the bottle is aligned with the level sensor 6 Check that the product bottle inserted into the bottle holder is pressed against the level sensor Only then the correct adjustment of the level sensor is possible Procedure to Adjust the Level Sensor 1 Turn controller power switch ON 2 Remove the metal screw from the level sensor 3 With an elect...

Страница 13: ...alve Recommended maximum idle times for different products are shown below Adhesive Maximum idle time for dispensing Systems Anaerobic 2 weeks Cyanoacrylate 1 week UV acrylate 2 weeks Acrylate 1 week Epoxy 2 weeks Activator n a Primer n a 6 2 Returning to Operation after Longer Periods of Non use Reconnect the pneumatic supply to the unit Check the installation according to Chapter 4 Return to ope...

Страница 14: ...rrectly connected or defect Check the dispensing valve see instruction manual for dispensing valve Product reservoir not switched on Check product reservoir Product reservoir is empty Refill product reservoir see Section 4 3 Air bubble in the product Product reservoir is empty Refill product reservoir see section 4 3 Dispensing valve not correctly connected or defective Check the dispensing valve ...

Страница 15: ...de of the feedline hose Remove the product bottle and insert a container with approx 0 5 liter of cleaning agent Put on the reservoir lid 7 and uniformly tighten the reservoir locking knobs 6 Operate the dispenser continuously until dry air streams out of the dispensing valve see operating instructions for the dispensing valve Remove the empty cleaning agent container 8 3 Maintenance Check the res...

Страница 16: ...tr 33ft length 142646 4 Tank Lid O ring for Reservoir 478505 5 Pressure Safety Relief Valve 360462 6 Anti Bubbler Kit 2 Adapters 2 Sleeves 478569 7 Silicone Grease 6 Gram Tube 88722 Accessories 1 Loctite Air Filter Regulator Gauge Mechanical version US 478603 Loctite Air Filter Regulator Gauge Mechanical version EU Asia 88649 10 Diagrams EQ RC30 Manual Reservoir Pin Connection ...

Страница 17: ...shable items such as fuses filters lights etc No such claim shall be allowed in respect of products which have been neglected or improperly stored transported handled installed connected operated used or maintained In the event of unauthorized modification of the Products including where products parts or attachments for use in connection with the Products are available from Henkel the use of prod...

Страница 18: ...ENT POSSIBLE UNDER APPLICABLE LAWS HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF OR OTHERWISE IN CONNECTION WITH THE PRODUCTS INCLUDING WITHOUT LIMITATION LOSS OF PROFITS AND SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES WHETHER CAUSED BY NEGLIGENCE FROM HENKEL OR OTHERWISE 12 Declaration of Conformity TO BE CO...

Страница 19: ... Haw Par Technocentre SINGAPORE 149598 Henkel China Company Ltd No 928 Zhang Heng Road Zhangjiang Hi Tech Park Pudong Shanghai China 201203 Henkel Loctite Korea 8F Mapo Tower 418 Mapo dong Mapo gu Seoul 121 734 KOREA Henkel Japan Ltd 27 7 Shin Isogo cho Isogo ku Yokohama 235 0017 JAPAN Henkel AG Co KGaA Henkelstraße 67 40191 Düsseldorf Deutchland www equipment loctite com and designate trademarks ...

Отзывы: