If the cartridge is not in the correct position, the trigger (9) cannot be pressed.
•
Connect the dispenser to the compressed air supply
Dispensing the adhesive
Press the trigger (9). Dispensing is started, and the red dispense
volume indicator (4) moves forward. When the trigger (9) is released,
dispensing stops.
The dispense volume can be controlled by means of the pressure reducing valve
(10).
a) Pull the pressure reduction valve.
b) Adjust the dispense volume by turning the adjuster in the + or –
direction.
c) Press the pressure reduction valve to confirm the set value.
Do not remove, tamper or manipulate pressure limiting valve and strictly respect
pressure limits.
Removing the cartridge
Release the trigger (9) and press the red button (13) until the feed
plungers have retracted to the back end-stop. Using the release
button (7), push the cartridge
out of the cartridge retainer and
pull it upwards out of the unit.
Dispose of the cartridge and mixer in conformity with the manufacturer’s
specifications.
5.
Troubleshooting:
Problem
Potential Cause
Remedy
Plunger discs cannot
enter the cartridge
Cartridge not fully
inserted in cartridge
bed
Check that there is
no foreign matter in
the cartridge bed.
Push the cartridge
fully down into the
cartridge bed.
Mind
your fingers.
The cartridge cannot
be removed from the
dispenser
.
The plunger discs are
still in position inside
the cartridge
.
Press the red button
to fully retract the
plunger discs to the
back end-stop.