5

3. Technical Data

Air inlet ports

(2) 4" dia. and (2) 2.5" dia.  

Fan capacity 

700 cfm / 1165 m

3

/h

System capacity

200 cfm / 335 m

3

/h

Max. static pressure

3.5" WG / 875 Pa

Power supply

115 V, 1 phase, 60Hz

Motor rating

0.75 HP / 560 watts

Power consumption

10 Amps 

Noise level, approx.

60 dBA

Certifications

UL, CSA

Dimensions (W x D x H)

15.5" (395 mm) x 19.5" (495 mm) x 27" (685 mm)

Weight (approx.)

100 lbs. / 45 kg

4. Installation

4.1 Installation and Connection

In order to properly install the Air Filtration System, the following procedure should be followed:

• Open the Unit’s top cover by releasing the four latches and removing the lid.

• Remove pleated prefilter.

• Remove carbon filter tray.

• Install the white mat on the bottom of the metal carbon filter tray.

• Fill the carbon tray with activated carbon. The activated carbon is supplied in a separate bag. 

• Check to insure afterfilter mat is properly seated.

• Install carbon tray into Unit

• Install pleated prefilter.

• Install the Unit’s top cover and secure the four latches.

• Attach a flexible hose to the air inlet port(s), on the lid, using hose clamps. If the sum of the

ports are not being used, keep them closed with a blind cover.

• Attach the other end of the hose to a suction nozzle, exhaust arm, or matching duct.

• Assure that all duct and hose connections are airtight. Leakage will result in decreased

performance.

• External on/off foot switch: Connect the series plug, which is attached to the power cord coming

from the foot switch, to wall outlet. Plug the filter systems power cord (3-prong plug) into the
receptacle of the series plug. 

• The Loctite

®

Air Filtration System is ready to be turned on.

Содержание 98276

Страница 1: ...EQUIPMENT Operation Manual Loctite Air Filtration System Part Number 98276 ...

Страница 2: ...ENTS AND CONSTRUCTION 2 2 2 THEORY OF OPERATION 3 2 3 FILTERING METHOD 3 4 2 4 THERMAL OVERLOAD PROTECTION 4 3 TECHNICAL DATA 5 4 INSTALLATION 5 4 1 INSTALLATION AND CONNECTION 5 5 MAINTENANCE AND CLEANING 6 7 5 1 FILTER UNIT 6 5 2 FILTER REPLACEMENT 6 7 6 TROUBLESHOOTING 7 7 SPARE PARTS AND ACCESSORIES 8 7 1 REPLACEMENT FILTERS 8 7 2 ACCESSORIES EXHAUST ARM KIT 8 7 3 ACCESSORIES EXHAUST CABINET K...

Страница 3: ... secure WARNING Use only original equipment filters WARNING Do not operate the Unit without filter inserts Contaminants in the extracted air will damage the blower WARNING Always disconnect the power supply before servicing the Unit WARNING Never cover intake or exhaust openings WARNING This system is equipped with automatic reset overload protection thermal switch or overload relay which may caus...

Страница 4: ... differential pressure gauge indicates the filter status 2 Description 2 1 Operating Elements and Construction Main Switch Foot Switch A foot switch is used to turn the filter unit on and off This switch needs to be located as far away from the filter unit as possible Filter Monitor Differential Pressure Gauge Filter Monitor The differential pressure gauge monitors the filter condition by measurin...

Страница 5: ...od The contaminated air is drawn into the filter unit and passes through a combination of filters Filtration is accomplished in three stages The pleated prefilter removes coarse particles such as dust The gas phase filter absorbs gases and odors The efficiency and lifetime of the gas phase filter depends on a range of variables which are among others flow rate temperature humidity concentration le...

Страница 6: ...austed air for contamination The lifetime is measured in operating hours until breakthrough occurs An optional way is a laboratory evaluation of the spent gas phase filter media after a certain time period For further information contact our customer service department 2 4 Thermal Overload Protection The filter unit motor is equipped with factory installed automatic thermal overload protection In ...

Страница 7: ...metal carbon filter tray Fill the carbon tray with activated carbon The activated carbon is supplied in a separate bag Check to insure afterfilter mat is properly seated Install carbon tray into Unit Install pleated prefilter Install the Unit s top cover and secure the four latches Attach a flexible hose to the air inlet port s on the lid using hose clamps If the sum of the ports are not being use...

Страница 8: ...pty the filter tray by pouring the saturated filter media into a waste container Dispose of carbon tray filter mat Caution Used filter media may contain toxic or flammable substances Observe relevant codes for safety and local hazard s material disposal Install the white mat on the bottom of the metal carbon filter tray Fill the carbon tray with activated carbon The activated carbon is supplied in...

Страница 9: ...ug The Loctite Air Filtration System is to be turned on Do not operate the filter system without filters installed This may overload the electric motor Caution Do not clean the filters Cleaning the filters by batting or using compressed air will destroy the filter Always use a new replacement filter 7 5 Maintenance and Cleaning continued 6 Troubleshooting Type of Malfunction Possible Causes Soluti...

Страница 10: ... Cover Latches 4 Pack 1 987357 2 5 Vent Plug 2 Pack 1 987358 4 Vent Cap 2 Pack 7 2 Accessories Exhaust Arm Kit 1 987351 Omni Flex Exhaust Arm ESD 2 5 dia 24 long reach includes rectangular nozzle universal mounting plate connection hose and wall mounting kit 1 987388 Connection Hose 2 5 diameter 8 long with hose clamps 1 987390 Mounting Kit consists of mounting angle and C clamps 7 3 Accessories E...

Страница 11: ...cts are available from Henkel Loctite the use of products parts or attachments which are not manufactured by Henkel Loctite no claim shall be allowed No Products shall be returned to Henkel Loctite for any reason without prior written approval from Henkel Loctite Products shall be returned freight prepaid in accordance with instructions from Henkel Loctite NO WARRANTY IS EXTENDED TO ANY EQUIPMENT ...

Страница 12: ...k Crossing Rocky Hill CT 06067 3910 Henkel Loctite Automotive Technology Center 2455 Featherstone Road Auburn Hills Michigan 48326 Henkel Loctite Canada Inc 2225 Meadowpine Boulevard Mississauga Ontario L5N 7P2 Henkel Ltda Brazil Av Prof Vernon Krieble 91 06690 11 Itapevi São Paulo Brazil Henkel Mexicana S A de C V Calzada de la Viga s n Fracc Los Laureles Loc Tulpetlac C P 55090 Ecatepac de Morel...

Отзывы: