25 PIN I/O
CONNECTOR
TO ROBOT

GROUND CONNECTION
(USE ANY POSITION)

+24 VOLTS
FROM ROBOT

RELAY CONNECTIONS

NO

DIODE (MANDATORY)

TURN ROBOT OUTPUT1 ON
TO ENERGIZE SOLENOID

24 VOLT DC SOLENOID
DO NOT EXCEED ROBOT
OUTPUT CURRENT LIMIT
OF 250 mA (TOTAL CURRENT,
TAKING INRUSH INTO ACCOUNT)

EXAMPLE 1: OPERATE A SOLENOID CONTROL VALVE USING
ROBOT OUTPUT  #1 AND THE ROBOT INTERNAL POWER SUPPLY

OUTPUT CIRCUITS

- PLACE JUMPER ACROSS PINS AT "OUT 1" TO PUT +24 VOLTS ON COMMON (POLE) OF RELAY # 1
- CONNECT THE NORMALLY OPEN CONTACT OF OUTPUT #1 TO THE COIL (+)
- CONNECT THE OTHER SIDE OF THE COIL (-) TO THE GROUND CONNECTION
- PLACE CLAMPING DIODE ACROSS COIL AS SHOWN

JUMP PINS OF "OUT 1"

 

 

25 PIN I/O
CONNECTOR
TO ROBOT

RELAY CONNECTIONS

DIODE (MANDATORY)

TURN ROBOT OUTPUT1 ON
TO ENERGIZE SOLENOID

24 VOLT DC SOLENOID
DO NOT EXCEED OUTPUT
CURRENT LIMIT OF EXTERNAL
SUPPLY OR RELAY CONTACT RATINGS

EXAMPLE 2: OPERATE A SOLENOID CONTROL VALVE USING
ROBOT OUTPUT #1 AND AN EXTERNAL POWER SUPPLY

       NO  COM

24 VOLT DC EXTERNAL POWER SUPPLY

OUTPUT CIRCUITS

- CONNECT THE +24 VOLTS FROM THE EXTERNAL SUPPLY TO THE COMMON OF RELAY #1
- CONNECT THE NORMALLY OPEN CONTACT OF OUTPUT #1 TO THE COIL (+)
- CONNECT THE OTHER SIDE OF THE COIL (-) TO THE GROUND OF THE EXTERNAL SUPPLY
- PLACE CLAMPING DIODE ACROSS COIL AS SHOWN

Содержание 1461974

Страница 1: ...24 volt unit If it is not do not use this junction box or damage to the robot and or junction box will result 2 CAUTION Cables cannot be connected or disconnected from the robot while the robot is on If this occurs the robot will be damaged 3 CAUTION Do not connect 24 volts to P_GND directly no load or damage to I O board may result 4 Robot inputs must only be turned on by means of a dry contact s...

Страница 2: ...L IS ON GREEN LEDS LIGHT WHEN RESPECTIVE OPTO COUPLER IS ON JUMPERS PASS 24 VOLTS FROM ROBOT TO COM OF RESPECTIVE RELAY RELAYS 8 24 VOLT JUNCTION BOX INTERNAL LAYOUT 25 PIN I O CONNECTOR TO ROBOT EXTERNAL SWITCH EXAMPLE 1 TURN ON ROBOT INPUT 1 USING AN EXTERNAL DRY CONTACT SWITCH GROUND CONNECTION USE ANY POSITION CONNECTION TO ROBOT INPUT 1 INPUT CIRCUITS CONNECT INPUT 1 TO ONE SIDE OF THE EXTERN...

Страница 3: ...S EXAMPLE 2 TURN ON ROBOT INPUT 1 USING A 24 VOLT DC LOW LEVEL SENSOR WITH PNP SOURCING OUTPUT PLACE A JUMPER ACROSS PINS AT IN1 CONNECT V OF THE SENSOR TO THE ROBOT 24 VOLT CONNECTOR CONNECT THE SENSOR GROUND TO THE JUNCTION BOX GROUND CONNECTOR CONNECT THE SENSOR OUTPUT COLLECTOR TO RELAY COIL CONNECT THE SIDE OF THE COIL TO THE ROBOT GROUND INSTALL CLAMPING DIODE ACROSS RELAY COIL AS SHOWN V OU...

Страница 4: ... DIODE MANDATORY SENSOR JUMP PINS AT POSITION 1 INPUT CIRCUITS RELAY COIL CURRENT MUST NOT EXCEED THE SENSOR OUTPUT LIMIT PLACE A JUMPER ACROSS PINS AT IN1 CONNECT V OF THE SENSOR TO THE ROBOT 24 VOLT CONNECTOR CONNECT THE SENSOR GROUND TO THE JUNCTION BOX GROUND CONNECTOR CONNECT THE SENSOR OUTPUT COLLECTOR TO THE COIL CONNECT THE SIDE OF THE COIL TO 24 VOLTS INSTALL CLAMPING DIODE ACROSS RELAY A...

Страница 5: ...COIL CONNECT THE OTHER SIDE OF THE COIL TO THE GROUND CONNECTION PLACE CLAMPING DIODE ACROSS COIL AS SHOWN JUMP PINS OF OUT 1 25 PIN I O CONNECTOR TO ROBOT RELAY CONNECTIONS DIODE MANDATORY TURN ROBOT OUTPUT1 ON TO ENERGIZE SOLENOID 24 VOLT DC SOLENOID DO NOT EXCEED OUTPUT CURRENT LIMIT OF EXTERNAL SUPPLY OR RELAY CONTACT RATINGS EXAMPLE 2 OPERATE A SOLENOID CONTROL VALVE USING ROBOT OUTPUT 1 AND ...

Страница 6: ...ne Boulevard Mississauga Ontario L5N 7P2 Henkel Capital S A de C V Calzada de la Viga s n Fracc Los Laureles Loc Tulpetlac C P 55090 Ecatepac de Morelos Edo de México Henkel Corporation Automotive Metals HQ 32100 Stephenson Hwy Madison Heights MI 48071 Henkel Ltda Rua Karl Huller 136 Jd Canhema 09941 410 Diadema SP Brazil www loctite com and designate trademarks of Henkel Corporation or its affili...

Отзывы: