![Locosys LS2003J-G Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/locosys/ls2003j-g/ls2003j-g_manual_1933712005.webp)
LOCOSYS Technology Inc.
20F.-13, No.79, Sec. 1, Xintai 5th Rd.,
Xizhi Dist., New Taipei City 221, Taiwan
℡
886-2-8698-3698
886-2-8698-3699
www.locosystech.com/
Page
5/23
© 2018 LOCOSYS Technology Inc.
6
DC & Temperature characteristics
6.1
Absolute maximum ratings
Parameter
Symbol
Ratings
Units
Input Voltage
VCC
4.3
V
Input Backup Battery Voltage
V_BCKP
4.3
V
Operating Temperature Range
Topr
-40 ~ 85
℃
Storage Temperature Range
Tstg
-40 ~ 85
℃
6.2
DC Electrical characteristics
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Units
Input Voltage
VCC
3.0
3.3
4.3
V
Input Backup Battery Voltage
V_BCKP
2.0
4.3
V
Supply Current
Icc
VCC = 3.3V,
w/o active antenna,
Peak
Acquisition
Tracking
Standby
36
37
(2)
441
148
(1)
mA
mA
mA
uA
Backup Battery Current
I
VSTBY
VCC = 0V
10
uA
High Level Input Voltage
V
I H
2.0
3.6
V
Low Level Input Voltage
V
I L
-0.3
0.8
V
High Level Input Current
I
I H
no pull-up or down
-1
1
uA
Low Level Input Current
I
I L
no pull-up or down
-1
1
uA
High Level Output Voltage
V
OH
2.4
3.3
V
Low Level Output Voltage
V
OL
0.4
V
High Level Output Current
I
OH
2
mA
Low Level Output Current
I
OL
2
mA
Note 1: This happens when downloading AGPS data to LS2003J-G.
Note 2: Measured when position fix (1Hz) is available, input voltage is 3.3V and the function of self-generated ephemeris
prediction is inactive.
6.3
Temperature characteristics
Parameter
Symbol
Min.
Typ.
Max.
Units
Operating Temperature
Topr
-40
-
85
℃
Storage Temperature
Tstg
-40
25
85
℃