background image

DU40•20 Technical Manual EN 150624

© 2015 www.Lock4Safe.com

Page 2 of 4

The  Lock  is  delivered  with  the  Bolt  retracted  and  ready  for
mounting. Do not move the cam (part with square hole) or the
bolt. During installation the bolt must stay in retracted position
and cam lined up as shown right.

1

Prepare the mounting and cable / spindle holes

2

Remove the small combination dial in the middle of the input unit
and remove the spacer ring. (do not throw away!)

3

Put the input electronic cable through the hole in the container door.
Be sure cable is inserted down into the slot in the back of the
keypad housing. Mount the input with two entry screws M4. Do not
tighten the screws yet.

4

Using the mounting screws, mount the lock in the correct position on
the inside of the safe door. Take note of any modifications that may
be needed to accommodate a relocker. Use Loctite to secure the
screws (approximately 3.5 Nm torque). Plug the four input’s prong
connector into the ENT slot of the lock. Thereafter, press the nose of
the plug lightly behind the metal housing so that it does not come
loose during use.

5

Cut the shaft for the mechanical dial and deburr both ends. Length:

41 mm + D

(=door thickness). Insert the cut shaft into the square

hole of the DIAL.

6

Align the input unit (with mounting tool LS-1526) and tighten the 2
screws (hand tight)

7

For a first test, place the previously removed spacer (see 2)
between the dial and the keypad housing. With the bolt still
retracted, push the dial lightly into the keypad hole on approximately
number 93 of the dial.

8

Turn the dial LEFT to extend the bolt. In the LOCKED position, there
should be approximately 1 mm clearance between the lock bolt and
the cavity in the blocking bar of the boltwork. The lock bolt must
move freely into the cavity. Turn the dial several times to assure that
it turns freely.

Содержание DUET DU4020

Страница 1: ... DIxxxx as shown in this instruction or with any approved entry unit and separate dial The lock is driven by a 4 7 mm 3 16 inch square spindle a spline key is not required The distance between change and opening index is 8 numbers The construction of the security container needs to include protection against destructive force from outside and should not give access to security relevant parts of th...

Страница 2: ...be needed to accommodate a relocker Use Loctite to secure the screws approximately 3 5 Nm torque Plug the four input s prong connector into the ENT slot of the lock Thereafter press the nose of the plug lightly behind the metal housing so that it does not come loose during use 5 Cut the shaft for the mechanical dial and deburr both ends Length 41 mm D door thickness Insert the cut shaft into the s...

Страница 3: ...er the spindle only to separate it from the cable 12 Remove the spacer With the lock in OPEN position bolt retracted hold the dial in a way that approximately 93 is lined up with the dial s opening mark and push it with light pressure into the lock The dial and shaft cannot be pulled back out as they are held by a starlock washer 13 Place the small plastic plug into the shaft hole at the rear of t...

Страница 4: ...dial if a number is passed start over at the beginning After the new Code is completely entered turn change key LEFT and remove it The new Code is installed Try the new code several times using Opening Index before closing the door What if accidentally the cam got moved before installation As long as the code has not been changed with the change key the lock can be prepared for mounting following ...

Отзывы: