4.Operation instructions
5.
Quick setting
Turn on the unit :
The unit itself does self -testing when the power is on.
Current time is shown on display screen when self-testing is completed.
Proximity :
Sense the card near the unit. The following States are shown below.
(A)OK (Green) light is on to indicate registered card to gain access.
(B)DENY (Red) light is on and consecutive beeping sound is on to indicate unregistered card
or use under unauthorized time zone.
(Please refer to Troubleshooting
if none of the above occurred)
Proximity and Password Door Opening :
Door Open mode is set as 3. Sense the card and
enter 4-digit password and then press # button to open door .
Anti-duress :
When under duress, user may press
button before keying in password to
activate alarm. (Duress code presetting is
, it can be changed by user)
Example : anti-duress code is 1, password is 1 2 3 4, then to activate
anti-duress alarm, the user should key in
1 2 3 4
.
Note : This function is only available for Door Open Mode 3-proximity and password mode.
Setup Mode :
User must get into setting mode first before changing any system functions. User must
enter
system password
for system function selection. System password is being
set as 5 6 7 8 (default).
(Example: User can get into the set up mode by keying
5 6 7 8
).
P16
Add new card : enter
0 1
and then enter
0 0 0 0 0 0 0 1
or proximity card .
8-digit card number
Delete card : enter
0 2
and then enter
0 0 0 0 0 0 0 1
8-digit card number
Shunt time : enter
0 4
and then enter the seconds
0 0 3
Seconds
Reader ID number : enter
1 0
and then enter the reader number
0 0 2
Door open mode : enter
0 5
and then enter the mode code
2
Door open mode
User will get into the setup mode as the right diagram shown for any setting to be made.