![Locinox SlimStone-2 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/locinox/slimstone-2/slimstone-2_manual_1933372012.webp)
EN
EN
12
SlimStone-2
In case an invalid number is entered, all lights
flash three times. Start over. Menu [5] remains
activated.
6.7 SET PULSE REPETITION [7]
If one or both of the relays are set to pulse mode,
additional pulses can be given by pressing [#]
without the need to re-enter the PIN code. This menu
allows setting the duration of this pulse repetition
timeframe.
• Access programming mode (see 6.1)
• Press [7] and confirm with [#]
• [7] and [#] are both lit
• Enter the timeframe within which pulse repetion is
allowed (between 1 and 99 seconds), and press
[#] (0s will disable pulse repetition)
• If a valid value is entered all lights will light up, you
will return to the main menu
In case of an invalid value, all lights will flash
three times. Menu 7 remains activated.
By default the value is set to ‘no pulse repeti-
tion’.
6.8 KEYPAD HEATING [8]
• Access programming mode (see 6.1)
• Press [8] and confirm with [#]
• [8] and [#] are both lit
• Select the mode for the keypad heating:
[1] Full power heating (default): The keypad
heating can consume up to 12W of power
[2] Half power heating: The power consumed for
keypad heating is limited to a maximum of 6W.
[3] No heating: The keypad heating is disabled.
• Press [1], [2] or [3] and confirm with [#]. When
all LEDs flash, your choice has been saved.
• You are back in the main menu of the
programming mode
In case of an invalid value, all lights will flash three
times. Start over. Menu [8] remains activated.
6.9 FACTORY RESET [0]
• Access programming mode (see 6.1)
• Press [0] and confirm with [#]
• [0] will flash rapidly to indicate an irreversible
action can be taken
• Enter the Master PIN and confirm with [#]
for 2
seconds
• When all LEDs flash, the factory reset is complete.
All settings are restored to default values except
for the Master PIN
6.10 FACTORY RESET UPON LOSS
OF MASTER PIN
Perform a factory reset without a Master PIN:
• Switch the power supply off and on, enter the
default Master PIN ‘12345’ and confirm by press
and holding [#] for 2 seconds within 20 seconds
• The factory reset is complete
• In case of a factory reset as described above, the
Master PIN is reset to ‘12345’
7. FUNCTIONING OF
SLIMSTONE-2
7.1 ENTER A CORRECT CODE
• Enter a personal code (min. 4 - max. 8 digits)
• Press [#] to confirm the code
• In case the code is only valid for 1 relay, the relay
will be activated immediately
• In case the code is valid for both relay 1 and 2,
buttons [1] and [2] will flash. Press [1] and/or [2]
to activate relay 1 and/or relay 2.
• The corresponding button lights up, and a light
sequence runs from the bottom to the top during
the time the relay is energised (default time is 8
seconds)
• If the sequence light stops, the relay is no longer
energised. The SlimStone-2 is ready for a new
code.
7.2 ENTER A WRONG CODE
• Enter a wrong code
• Press [#] to confirm the code