Hazard definitions

The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels 
or to important information concerning the life of the product.

 DANGER

 WARNING

 CAUTION

 CAUTION

 NOTICE

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious 
injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious 
injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or 
moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not 
avoided, may result in property damage.

NOTICE indicates special instructions on installation, operation, or maintenance that are important but not 
related to personal injury or property damage.

HAZARD DEFINITIONS

 ....................................................  2

PLEASE READ BEFORE PROCEEDING

 ........................  3

1.  GENERAL INFORMATION

Operating Restrictions ........................................................  4
Single-Wall Heat Exchanger ..............................................  4

2.  PRE-INSTALLATION

Locating the Tank ...............................................................  5
Recommended Clearances ................................................  5 

3.  BOILER SIDE PIPING

Zone with Circulator to Aquastat ........................................  6
Zone with Valve to Aquastat ..............................................  6     
DHW Prioritization ..............................................................  6
Multiple Tank Connections (Boiler Side) ............................  6
     Table 3A - Pressure Drop Chart ...................................  6
     Table 3B - Pressure Drop Values .................................  6
Piping Diagrams ............................................................ 7-10

4.  DOMESTIC SIDE (TANK) PIPING

    Basic Domestic Piping .................................................  11
    Multiple Tank Domestic Water Piping ..........................  11
    Domestic Water Piping for Distant Fixtures .................. 11  

      Anti-scald Valves (Mixing Valves) .............................  12
      Install Drain Valve ......................................................  12
     Temperature and Pressure (T&P) Relief Valve ..........  12
          Table 4A - Minimum Relief Valve (AGA Rating) ...  13

5.  WIRING

Indirect Water Heater Sensor Setup (Knight Boiler) ........  15
     Install and Connect Tank Sensor ...............................  15
Indirect  Water Heater Controlled Using Aquastat and 
Zone Circulator .................................................................  16

6.  START-UP AND CHECK-OUT

 ..................................  17

7.  MAINTENANCE

Maintenance Schedule .....................................................  18

    

 To Fill the Water Heater .............................................  18

     

To Drain the Water Heater .........................................  18

8.  PERFORMANCE DATA

IBR Chart..........................................................................  19
How to Properly Size Your Indirect Water Heater ...........  20
Performance Data Charts ........................................... 21-23

REVISION NOTES

 ............................................  Back Cover

Contents

Содержание SQUIRE SIT030

Страница 1: ...d result in severe personal injury death or substantial property damage WARNING Save this manual for future reference SIT I O Rev H CAUTION The heat transfer medium must be water or other nontoxic flu...

Страница 2: ...EFORE PROCEEDING 3 1 GENERAL INFORMATION Operating Restrictions 4 Single Wall Heat Exchanger 4 2 PRE INSTALLATION Locating the Tank 5 Recommended Clearances 5 3 BOILER SIDE PIPING Zone with Circulator...

Страница 3: ...AS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instruc...

Страница 4: ...PT SEE NOTE 1 2 SIT030 SIT119 PART NO A in B in C in D in E in F in SIT030 SIT040 SIT050 SIT065 SIT080 SIT119 3 1 16 3 1 16 3 5 8 3 5 16 3 5 16 3 5 16 8 3 16 8 3 16 9 1 8 9 1 8 9 1 8 9 3 8 21 3 4 25 1...

Страница 5: ...or appliance and must also be kept vertical on a level surface 2 Keep distance between boiler and water heater to a minimum to a reduce piping heat loss b provide minimal friction loss 3 Figure 1 1 on...

Страница 6: ...s properly sized piping and a properly sized pump The system shown in FIG s 3 1 thru 3 4 are described below Zone with circulator to Aquastat This system is like the circulator zone system on a straig...

Страница 7: ...EXCEED 4 PIPE DIA OR A MAXIMUM OF 12 APART TANK SENSOR AQUASTAT RELIEF VALVE Y STRAINER DRAIN FIELD SUPPLY HOT WATER OUT ANTI SCALD MIXING VALVE RECIRCULATION PUMP CHECK VALVE DRAIN ZONE 1 ZONE 2 ZONE...

Страница 8: ...D SYSTEM CIRCULATOR SYSTEM SUPPLY SENSOR WHEN USED NOT TO EXCEED 4 PIPE DIA OR A MAXIMUM OF 12 APART TANK SENSOR AQUASTAT RELIEF VALVE Y STRAINER DRAIN FIELD SUPPLY RECIRCULATION PUMP CHECK VALVE DRAI...

Страница 9: ...IN POINT TYPICAL MAKE UP WATER FROM SYSTEM BOILER CIRCULATOR SYSTEM CIRCULATOR TO SYSTEM SYSTEM SUPPLY SENSOR DRAIN DRAIN FIELD SUPPLY RECIRCULATION PUMP TANK SENSOR AQUASTAT Y STRAINER RECOMMENDED HO...

Страница 10: ...RELIEF VALVE TYPICAL TANK SENSOR AQUASTAT TYPICAL CHECK VALVE SQUIRE SQUIRE BACKFLOW PREVENTER PRESSURE REDUCING VALVE PRESSURE GAUGE AIR SEPARATOR EXPANSION TANK BALL VALVE TYPICAL MAKE UP WATER FROM...

Страница 11: ...reverse return piping layout see FIG 3 4 Each tank must have its own T P valve It is recommended that each tank be equipped with its own isolation valves unions and drains so that one tank may be rem...

Страница 12: ...sed with water heaters are also called tempering valves or mixing valves An anti scald valve mixes cold water in with the outgoing hot water to assure that hot water reaching a building fixture is at...

Страница 13: ...of piping can reduce discharge capacity directly connected to a drain Refer to local codes subject to freezing WARNING Do not install any valve between the T P relief valve and the tank connection or...

Страница 14: ...VALVE SHUT OFF VALVE ANTI SCALD MIXING VALVE DRAIN FIELD SUPPLY RECIRCULATION PUMP TO BOILER FROM BOILER CHECK VALVE TANK SENSOR AQUASTAT SQUIRE Figure 4 2 Recommended Domestic Water Piping Please not...

Страница 15: ...sensor has a built in high temperature limit set at 194 F NOTICE The sensor supplied contains an Auto Reset High Limit 194 F 3 The Knight boiler will automatically read the sensor and default the tank...

Страница 16: ...ntrol TST20016 can be ordered from your local Lochinvar distributor 2 Connect Aquastat to the zone controller for the Indirect Water Heater Zone 3 Adjust Aquastat to the desired temperature INDIRECT T...

Страница 17: ...xtended period of time after installation Flush the indirect water heater by drawing at least three times its volume from the tank 3 Make sure that all electrical connections are made correctly and th...

Страница 18: ...s to allow air to escape from the system 4 When a steady stream of water flows from the faucets the water heater is filled Close the faucets and check for water leaks at the water heater drain valve c...

Страница 19: ...IT030 27 0 1 1 1 5 160 183 99 000 14 0 3 9 SIT040 40 0 1 6 0 9 181 208 115 000 14 0 4 5 SIT050 51 6 1 7 0 8 209 255 133 000 14 0 5 3 SIT065 67 0 1 9 0 7 263 327 154 000 14 0 5 7 SIT080 81 5 2 1 0 6 26...

Страница 20: ...Hour Rating of no less than 165 gallons Fixture Count Guide To quickly estimate the minimum gallons of hot water required based on a family size number of baths and hot water appliances the First Hour...

Страница 21: ...9574 132764 94115 114116 125111 134044 146207 Boiler Heating Capacity Table 8B First Hour Rating 180 F Boiler Loop Water Knight Boiler First Hour Rating 180 F Boiler Loop Water Knight Boiler SIT065 SI...

Страница 22: ...ler Heating Capacity First Hour Rating 180 F Boiler Loop Water Universal Sizing 45 000 295 000 Btu hr Model SIT065 SIT080 SIT119 Circulator Flow GPM 5 8 12 16 20 5 8 12 16 20 5 8 12 16 20 Domestic Out...

Страница 23: ...Heating Capacity First Hour Rating 200 F Boiler Loop Water Universal Sizing 45 000 295 000 Model SIT065 SIT080 SIT119 Circulator Flow GPM 5 8 12 16 20 5 8 12 16 20 5 8 12 16 20 Domestic Outlet 115 14...

Страница 24: ...for section 3 Boiler Side Piping FIG 3 1 3 4 a new image for section 4 Domestic Side Tank Piping FIG 4 2 and the update of the Pressure Drop chart on page 6 Revision E ECO C06035 reflects the update o...

Отзывы: