background image

7

INSTALLING THE NEW WATER HEATER

MOUNTING

MOUNTING - DRYWALL (HOLLOW WALL)

1.  The selected wall or cabinet must be capable of supporting double 

the weight of the unit when completely full of water (77 Ibs).

2.  The installation area must provide adequate clearances for 

removal of the front panel and servicing the unit.

3.  Locate the wall studs in the area where the unit is to be 

mounted.

4.  Cut two sections of 1/2 inch plywood or equivalent material 3 

inches in height. The length of each section should be sufficient 
to span the width of the wall studs. See Figure 3A.

5.  Use appropriately sized nails or wood screws to attach the two 

wall supports to the wall as show in Figure 3A.

6.  Drill two 13/32 inch holes in the upper wall support NOTE: The 

holes must be level.

7.  Insert the hollow wall anchors into the drilled holes. Place the 

wall bracket over the anchors and screw the two phillips head 
screws down tight against the bracket.

MOUNTING - MASONRY WALL (SOLID WALL)

1.  The selected wall or cabinet must be capable of supporting double 

the weight of the unit when completely full of water (77 Ibs).

2.  The installation area must provide adequate clearances for 

removal of the front panel and servicing the unit.

3.  Drill two 13/32 inch holes in the masonry wall. NOTE: The 

holes must be level and at least 3-1/2 inches deep.

4.  Insert the masonry wall anchors into the drilled holes. Place 

the wall bracket over the anchors and screw the two phillips 
head screws tight against the bracket.

FIGURE  3A.

MOUNTING - FLOOR

1.  The floor selected must be capable of supporting double the 

weight of the unit when completely full of water (77 Ibs).

2.  The installation area must provide adequate clearances for 

removal of the front panel and servicing the unit.

3.  Place a suitable drain pan under the unit. The pan must limit the 

water to a maximum depth of 2-1/2 inches and be 2 inches wider 
than the unit. The pan must also be piped to an adequate drain. 
See Figure 3B.

FIGURE  3B.

WATER PIPING

HOTTER  WATER  CAN  SCALD: 
Water heaters are intended to produce hot water. Water heated to 
a temperature which will satisfy space heating, clothes washing, 
dish washing, cleaning and other sanitizing needs can scald and 
permanently injure you upon contact. Some people are more likely to 
be permanently injured by hot water than others. These include the 
elderly, children, the infi rm, or physically/mentally disabled. If anyone 
using hot water in your home fi ts into one of these groups or if there 
is a local code or state law requiring a certain temperature water at 
the hot water tap, then you must take special precautions. In addition 
to using the lowest possible temperature setting that satisfi es  your 
hot water needs, a means such as a mixing valve should be used at 
the hot water taps used by these people or at the water heater. 
Valves for reducing point of use temperature by mixing cold and 
hot water are also available.

Consult a Qualifi ed Installer or Service Agency. Follow manufacturer’s 
instructions for installation of the valves. Before changing the factory 
setting on the thermostat, read the “Temperature Regulation” section 
in this manual.

Содержание RESIDENTIAL ELECTRIC WATER HEATER

Страница 1: ... WATER HEATER WAS PURCHASED IFYOUAREUNSUCCESSFUL CONTACTTECHNICALASSISTANCEAT1 615 889 8900ORVIAE MAILAT2TECH LOCHINVAR COM LISTED Instruction Manual RESIDENTIAL ELECTRIC 2 5 GALLON 120 VOLT WATER HEATER FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING 300 Maddox Simpson Parkway Lebanon TN 37090 Phone 615 889 8900 Fax 615 547 1000 Technical Services email 2tech lochinvar com www lochi...

Страница 2: ...ead content as required in some areas IMPORTANT DEFINITIONS Qualified Installer A qualified installer must have ability equivalent to a licensed tradesman in the fields of plumbing and electrical installation of these appliances This would include a thorough understanding of the requirements of the National Electrical Code and applicable local electrical and plumbing codes and tools necessary to c...

Страница 3: ...3 GENERAL SAFETY ...

Страница 4: ...ater heater INSTALLATION OR SERVICE OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED PLUMBING AND ELECTRICAL WORK ARE REQUIRED Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual 5 For California installation this water heater must be braced anchored or strapped to avoid ...

Страница 5: ...abled If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve should be used at the hot water taps used by these people ...

Страница 6: ...d by a leak detector or water shut off device used in conjunc tion with a piped drain pan These devices are available from some plumbing supply wholesalers and retailers and detect and react to leakage in various ways Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected Sensors mounted in the drain pan that turn off the ...

Страница 7: ...t against the bracket FIGURE 3A MOUNTING FLOOR 1 The floor selected must be capable of supporting double the weight of the unit when completely full of water 77 Ibs 2 The installation area must provide adequate clearances for removal of the front panel and servicing the unit 3 Place a suitable drain pan under the unit The pan must limit the water to a maximum depth of 2 1 2 inches and be 2 inches ...

Страница 8: ...ed systems do not allow for the expansion of heated water The water within the water heater tank expands as it is heated and increases the pressure of the water system If the relieving point of the water heater s temperature pressure relief valve is reached the valve will relieve the excess pressure The temperature pressure relief valve is not intended for the constant relief of thermal expansion ...

Страница 9: ...flow may cause property damage The Discharge Pipe Shall not be smaller in size than the outlet pipe size of the valve or have any reducing couplings or other restrictions Shall not be plugged or blocked Shall be of material listed for hot water distribution Shall be installed so as to allow complete drainage of both the temperature pressure relief valve and the discharge pipe Shall terminate at an...

Страница 10: ...10 WIRING DIAGRAM FIGURE 5 ...

Страница 11: ...liar with the electric codes and practices or if you have any doubt even the slightest doubt in your ability to connect the wiring to this water heater obtain the service of a competent electrician Contact a local electrical contractor and or the local electric utility WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY This water heater is equipped for one type voltage only Check the rating plate near th...

Страница 12: ...r temperatures be used to avoid the risk of scalding It is further recommended in all cases that the water temperature thermostat be set for the lowest temperature which satisfies your hot water needs This will also provide the most energy efficient operation of the water heater KEEPING THE THERMOSTAT SETTING AT 120 F 49 C OR LOWER WILL REDUCE THE RISK OF SCALDS Figure 6 shows the approximate time...

Страница 13: ...n the water heater this harmless bacteria is nontoxic to humans D An excess of active hydrogen in the tank This is caused by the corrosion protective action of the anode Smelly water may be eliminated or reduced in some water heater models by replacing the anode s with one of less active material and then chlorinating the water heater tank and all hot water lines Contact the local water heater sup...

Страница 14: ...od sacrifices itself to protect the tank Instead of corroding the tank water ions attack and eat away the anode rod This does not affect the water s taste or color The rod must be maintained to keep the tank in operating condition NOTE Artificiallysoftenedwaterismorecorrosivebecausetheprocess substitutes sodium ions for magnesium and calcium ions The use of a water softener may decrease the life o...

Страница 15: ...n or replace it 1 Turn off and unplug the water heater from the electrical outlet and follow DRAINING INSTRUCTIONS 2 Remove the front panel see the REMOVING THE FRONT PANEL section in this manual Remove the insulation pad 3 Remove the two screws from the mounting bracket see Figure 10 being careful not to drop the screws into the unit as they will be difficult to retrieve Remove bracket and set sc...

Страница 16: ...or replacing the element in ELEMENT CLEANING REPLACEMENT HIGH LIMIT SWITCH REMOVAL AND REPLACEMENT 1 Turn off and unplug the heater from the electrical outlet 2 Remove the front panel see the REMOVING THE FRONT PANEL section in this manual Remove the insulation pad Remove personnel barrier 3 Remove the four wires connected to the switch taking care to note the original placement of each wire 4 Usi...

Страница 17: ...ater on the side of the tank may be condensation due to the panel or insulation not being in place E Water in the water heater bottom or on the floor may be from condensation loose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken Leakage from other appliances water lines or ground seep...

Страница 18: ...blem Possible Cause s Corrective Action These guidelines should be utilized by a qualified service agent TROUBLESHOOTING GUIDELINES Improperly sealed hot or cold supply connection relief valve or drain valve Leakage from other appliances or water lines No power to heater High Temperature Limit Switch open Non functioning thermostat Non functioning thermostat Improper calibration Thermostat set too...

Страница 19: ... number of your Water Heater will be found on the rating plate located above or adjacent to outer door WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION MODEL NUMBER SERIAL NUMBER VOLTAGE AND ELEMENT WATTAGE PART DESCRIPTION THIS IS A REPAIR PARTS LIST NOT A PACKING LIST FIGURE 13 1 Element Gasket 2 Anode Rod 3 Element Assembly with Gasket Anode Fasteners 4 High Limit with Personnel...

Страница 20: ...20 Copyright 2011 Lochinvar LLC All reights reserved 300 Maddox Simpson Parkway Lebanon TN 37090 Phone 615 889 8900 Fax 615 547 1000 Technical Services email 2tech lochinvar com www lochinvar com ...

Отзывы: