Maintenance Instructions for WS-3300

Danger – To Avoid Hazard of Electrical Shock or Burn, Turn Off 
Power Supply to Your WS-3300 Before Servicing.

The cleaner your WS-3300, the more efficiently it humidifies.

1. Shut off power and water supply.
2. Remove front cover
3.  Lift  front  of  distribution  tray  and  remove  evaporation 
pad.  Pad should be changed every 10-20 weeks depend-
ing on water condition.  (To reassemble, install distribution 
tray first, then while lifting the front of the distribution tray 
install bottom of evaporator pad, then push the pad back 
into position.  Lower distribution tray on top of the evapo-
rator pad.
4. All parts (except electrical components and pad) of the 
WS-3300 can be washed in a 50% solution of water and 
vinegar.  However, it is recommended that you purchase 
and replace the pan liner and evaporator pad every 10 to 
20 weeks.
5.  Wipe  any  loose  sediment  from  the  cabinet  with  your 
50% solution.  Make sure the drain hole and hoses are 
free of sediment and particles.

Annual Summer Shutdown

When its time to turn off your WS-3300 for the summer, 
turn your humidistat to the off setting.  It is recommended 
that  you  also  complete  the  above  5  easy  maintenance 
steps at this time.

Warning!

1.  120  volts  may  cause  serious  injury  from  electrical  shock.  
Disconnect electrical power to the furnace before starting instal-
lation.
2. Sharp edges may cause serious injury from cuts.  Use care 
when making plenum openings and handling duct work.
3. Hot water temperatures in excess of 125 degrees F. may cause 
serious  injury  from  burns.    Make  sure  water  supply  is  shut  off 
before connecting the water supply.

Caution!

1. Do not install unit where freezing temperature could occur.
2. Do not install unit on the furnace jacket.
3. Do not install unit on a plenum face where the blanked off ends 
of the cooling coil restrict air movement through the humidifier.
4. Do. Not set humidity higher than recommended.  Condensation 
dame may result.
5.  Do  not  connect  the  WS-3300  power  cord  to  multi-speed 
furnace blower motors other than 120 VAC.
6.  Do  not  set  humidity  up  to  recommended  levels  if  there  is 
condensation  on  the  inside  windows  of  any  unheated  living 
space.  Condensation damage may result.
7. Do not install unit on the supply plenum where static pressure 
exceeds 0.4” W.C.
8. Do not install the unit where water pressure exceeds 65 psi.  
Leakage may result.  Follow codes in effect concerning pressure 
reduction.

12.  Check  operation.    Open  saddle  valve  and  turn  on 
furnace.    Turn  up  the  humidistat  to  engage  the  WS-
3300.  Allow the unit to operate until water is observed 
running from the drain hose.  Check for any water leaks.  
If all functions are operating properly, reset humidistat 
to  recommended  level.    Place  owner’s  manual  near 
humidistat for owner.

Page Two                                                        Lobb WS-3300 Installation Instructions

NOTE: 

CHANGE EVAPORATOR PAD AT THE 

BEGINNING OF EACH SEASON. SHUT OFF 
WATER AND AIR FLOW AT THE END OF 
HEATING SEASON.