background image

Congratulations on the purchase of your new LoadSense Portable Weighing Kit. This 
product is designed to provide long service life and new levels of weighing 

fl

 exibility and 

portability. Although your kit comes equipped with a portable platform, you may wish to 
use the kit to weigh large objects. In these situations any suitable larger platform may be 
substituted. The kit’s modular design allows sensor placement to be adjusted according 
the size of platform you choose.

Please read the entire manual carefully before using the scale kit as improper use may 
cause injury or invalidate your warranty. We hope you 

fi

 nd the LoadSense Portable 

Weighing Kit to be a valuable tool for meeting your weighing needs.

V1.0, 2010 © LoadSense Technologies Corporation

Critical Safety Information

1.  Do not expose the scale to water or use in environments where it may be exposed 

to corrosives or high levels of moisture.   

 

 

 

2.  Use the scale on a hard, 

fl

 at and level surface to avoid accidents and to maximize 

weighing 

accuracy. 

      

3.  When using platforms other than the included acrylic platform, select a 

fl

 at  and 

stable item with the strength to hold your intended load while being supported by the 
four sensors from the outer corners. Refer to the instructions below for appropriate 
sensor placement. Suitable platforms include pallets, plywood, metal sheets, 
etc. Your platform should not weigh more than the Dead Load Capacity for your 
speci

fi

 c model (see Technical Speci

fi

 

cations). 

   

4.  Do not exceed the rated capacity of your speci

fi

 c scale model. Doing so may damage 

the sensors, result in injury and invalidate your warranty.   

 

5.  Place all loads in the center of the platform to prevent accidents and maximize 

weighing accuracy.  When centering the load, do not slide it on the platform as this 
also may cause damage and/or accidents. 

 

 

 

6.  Do not subject the scale to “load shock” by dropping either the platform onto the 

sensors or the load onto the platform. Such forces may exceed the maximum 
capacity of the scale and invalidate your warranty. Place all loads on the sensors 
and weighing platform in the gentlest manner possible. 

 

 

7.  Ensure that no power or connecting cords are caught between the components of 

the scale or in a position to cause a tripping hazard.  Never lift or move the sensors 
or weighing indicator by their cords. 

 

 

 

 

8.  Only use the supplied power adapter and winder cords with the kit. Do not insert any 

other types of plugs or cords into the jacks.

Important Safety and Operating Information – Read Before Use

Troubleshooting

V1.0, 2010 © LoadSense Technologies Corporation

Problem

Remedy

Display unit does not activate when turned 
on.

Check that the AC adapter 

1. 

is plugged properly into an 
active wall socket.

Con

fi

 rm that the AC 

2. 

adapter tip is fully inserted 
into the display unit.

If using battery power, en-

3. 

sure the protective plastic 
is removed.

Insert a new 9V battery to 

4. 

con

fi

 rm battery strength is 

not the issue.

Display activates but does not display “0.0”

OR

Display activates and displays “0.0” but 
does not change when a load is applied.

OR

Weight readings are clearly inaccurate.

Use the AC adapter to en-

1. 

sure a weak battery is not 
causing the problem.

Check for loose connec-

2. 

tions and reinsert any 
loose jacks or plugs.

If no loose connections 

3. 

are found, remove and re-
insert each jack and plug.

If the suggested remedies do not resolve your problem, please initiate a support 
request at www.loadsense.com/support.

Portable Kit Owners Manual v9.indd   Spread 2 of 4 - Pages(2, 7)

Portable Kit Owners Manual v9.indd   Spread 2 of 4 - Pages(2, 7)

1/13/10   7:19:32 PM

1/13/10   7:19:32 PM

Содержание PK-150K4-50

Страница 1: ...nse com International Patents Pending V1 0 2010 LoadSense Technologies Corporation ADDITIONAL IMPORTANT INFORMATION LoadSense products are warranted against defects in materials and workmanship for a period of one year from the date of purchase For complete warranty information please consult our website at www loadsense com warranty To ensure full warranty coverage and expedited support please re...

Страница 2: ... weighing accuracy When centering the load do not slide it on the platform as this also may cause damage and or accidents 6 Do not subject the scale to load shock by dropping either the platform onto the sensors or the load onto the platform Such forces may exceed the maximum capacity of the scale and invalidate your warranty Place all loads on the sensors and weighing platform in the gentlest man...

Страница 3: ...ear the outer four corners of the platform The round feet of the sensors should be in contact with the floor See Diagrams 1 and 2 4 Connect the first retractable cord to the display unit and the master sensor The master sensor has four jacks Be sure to connect the cord to the jack marked OUT See Diagram 3 5 Connect the three remaining retractable cords to the master sensor and then to the three sl...

Страница 4: ...110 240 Volts 2 International Adapter Plugs 3 Acrylic Weighing Platform 4 Spare Load Cell for authorized 5 service provider use only Carrying Case 6 Power Jack Input Jack LoadSensors Placement and Arrangement V1 0 2010 LoadSense Technologies Corporation Diagram 1 Proper placement of Load Sensors Diagram 2 Proper Orientation of Load Sensors Diagram 3 Master Load Sensor Jack Arrangement Portable Kit...

Отзывы: