Chapter 1: Common Issues
HYDROBAR EXPRESS 220
1-40
Chuck Closed Prior to Feed Out Complete
CLAMPING DEVICE HAS
CLOSED PRIOR TO
COMPLETING THE
FEED OUT
POSSIBLE CAUSES:
-LATHE PROGRAMMING
ERROR
-CLAMPING SIGNAL
FAULTY (PLC INPUT
A1)
Description:
The Clamping Device Has Closed Prior To Completing The Feed Out alarm occurs if the input for the clamping device closed is
detected before the value of the
Input Part Length
parameter is reached.
Solution:
Verify that the clamping device is closing properly and that the
Clamping Signal Active
interface parameter is set in conjunction with
how the interface signal is being sent.
Verify that the correct part length has been entered in the
PARAMETERS RELATED TO APPLICATIONS
menu.
Содержание Hydrobar Express 220
Страница 61: ......
Страница 143: ......
Страница 147: ......
Страница 154: ...Chapter 6 Spare Parts Spare Parts 6 7 HYDROBAR EXPRESS 220 Chapter 6 6 7 HYDROBAR EXPRESS 220 Chain Drive Assembly L F ...
Страница 155: ...6 8 Chapter 6 Spare Parts Spare Parts HYDROBAR EXPRESS 220 6 8 Chapter 6 HYDROBAR EXPRESS 220 Chain Drive Assembly R F ...
Страница 156: ...Chapter 6 Spare Parts 6 9 HYDROBAR EXPRESS 220 Servo Motor Assembly ...
Страница 157: ...6 10 Chapter 6 Spare Parts Spare Parts HYDROBAR EXPRESS 220 6 10 Chapter 6 HYDROBAR EXPRESS 220 Remnant Vise ...
Страница 158: ...Chapter 6 Spare Parts Spare Parts 6 11 HYDROBAR EXPRESS 220 Chapter 6 6 11 HYDROBAR EXPRESS 220 Sensor Support Assembly ...
Страница 161: ...6 14 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Hydraulic Pump Assembly ...
Страница 162: ...Chapter 6 Spare Parts Spare Parts 6 15 HYDROBAR EXPRESS 220 Chapter 6 6 15 HYDROBAR EXPRESS 220 Coding Disc Assembly ...
Страница 163: ...6 16 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Diameter Adjustment Motor Assembly ...
Страница 164: ...Chapter 6 Spare Parts 6 17 HYDROBAR EXPRESS 220 Air Regulator and Cable Passage Plate ...