NOTES
The FX-4A has an RIT function; and is accessed by [PH]
W/R switch. RIT will be display left of screen above filter
settings., Once in RIT mode there is two frequency’s
displayed. Bottom is Original VFO setting while the Top
(Large) numbers is the RIT setting. It is adjustable by
rotating the VFO knob. To exit RIT [PH] the W/R switch.
If FX-4A has a good match with antenna and power
supply voltage of 13.8 VDC, you should have 5 watts
output on CW and SSB operation.
CALL with CQ CQ CQ
Note: make sure you have configured FX-4a with your
Call. To do this, enter menu, by [PH] Band button. Cursor
down to CALL. Rotate VFO knob to select characters.
Tap Vol knob to set characters.
Cq Cq Cq can be used with your programmed call by
tap of CALL button knob.
Note: Verify H-SWR-P is set to 20 in configuration if unit
doesn't exit TX mode.
FX-4a Reset
To initiate FX-4a reset (to factory settings):
POWER OFF unit
[PH] MODE button and A/B button simultaneously while
powering up the unit.
Release after units powers up and displays “Init-OK”.