OUTPUT ADJUSTMENT  -  INITIAL APPROXIMATION

A. 

Speed control dial is graduated in approximate percent of maximum strokes per minute (spm).    

 

Turning this knob clockwise      increases pumping frequency. 

 

OUtpUt EStIMAtE  - total output of pump may be estimated by multiplying stroke frequency (percent of 
maximum) by stroke length setting (percent of maximum). For example, if the stroke length knob is set at 100% 
of maximum and the stroke frequency is 20% of maximum, total pump output will be approximately 20%; if 
the stroke length knob is set at 30% of maximum and stroke frequency is 20% of maximum, total output will 
be approximately 6% of the pump’s maximum rating. this is .2 x.3 = .06 or 6%.

 

B. 

To determine exact frequency in strokes per minute at any speed knob setting, count number of   

 

strokes for one minute.

 

C. 

Stroke length adjustment knob is the lower of the control panel knobs. Adjust by rotating to desired  

 

setting,while pump is stroking.

 

D. 

SETTING—Maximum output of the pump is obtained with stroke frequency knob set at maximum  

 

and stroke length knob set at maximum.

 

 

If pump is to be used at less than maximum output, best volumetric efficiency will be achieved if   

 

stroke  length knob is left at maximum, and stroke frequency knob rotated counter-clockwise      to 

 

 reduce pump  output. If more output reduction is required than can be achieved by reducing stroke  

 

frequency, reduce output by turning the stroke length knob counter-clockwise     .

 

E. 

After installation is complete and an initial approximation setting has been made, the pump should  

 

be calibrated and the stroke frequency and/or stroke length settings adjusted.

F. 

Nominal output and pressure ratings are at 100% settings of stroke frequency and stroke length.

 

    

 LMI accessories used with the Series E  pumps must be placed in an explosion proof enclosure or located 
in an area where they will not be subjected to explosion hazard.

 

 

WARNING:

   These accessories are not explosion proof and must be installed remotely in a non-   

 

 

hazardous  area or  mounted in an explosion proof enclosure.  Wiring must adhere to local electrical  

 

 

codes for hazardous  locations.

E7 Series metering pumps come equipped with four external control wires for operating the complete line 
of LMI accessories. Since hardwiring is essential for operating devices in hazardous locations, removal of 
the four pin connector from the accessory is necessary.  The chart below indicates proper wiring for each 
accessory.

E7 WIRING FOR ACCESSORIES

ACCESSORY

ACCESSORY               E7 WIRES
      WIRES

RFP Flowmeters
26034 Extension Cables

( Pin #)

     1     White . . . . . . . . . . . . .  Orange
     2     Black . . . . . . . . . . . . . . Violet
     3     Green . . . . . . . . . . . . .  Gray
     4     Red . . . . . . . . . . . . . . . Red

DP5000 pH Controllers
DR5000 ORP Controllers
DX6000 Controllers

     1     White . . . . . . . . . . . . . .Orange
     2     Black . . . . . . . . . . . . . . Violet
                   . . . . . . . . . . . . . . . .Gray     

(No Connection-wire cap)

                   . . . . . . . . . . . . . . . .Red

MP-100 Micropace
MP-400D Micropace
MP-500M Micropace

     

 . . . . . . . . . . . . . .. . . .Orange 

(No Connection-wire cap)

     2     Black . . . . . . . . . . . . . . Violet
     3     Green . . . . . . . . . . . . . Gray   
     4     White . . . . . . . . . . . . . . Red

        (No Connection-wire cap)

FC Flowmeters
26006 Pulse Transmitter (A7, B7, C7, P7)
41319 Pulse Transmitter (AA7)

     1     White . . . . . . . . . . . . . .Orange
     2     Brown . . . . . . . . . . . . . .Violet
                   . . . . . . . . . . . . . . . .Gray     

(No Connection-wire cap)

                   . . . . . . . . . . . . . . . .Red

        (No Connection-wire cap)

1718.D_306.indd   5

4/4/06   1:21:18 PM

Содержание E7 Series

Страница 1: ...rdering replacement parts for your LMI Pump please include the complete Model Number and Serial Number of your unit Replaces same of Rev C 10 97 1718 D 3 06 201 Ivyland Road Ivyland PA 18974 USA TEL 2...

Страница 2: ...sories 5 Output Adjustment Initial Approximation 5 Procedure for On Site Volumetric Calibration E7 in Internal Mode 6 Procedure for On Site Volumetric Calibration E7 in External Mode 6 2 0 Troubleshoo...

Страница 3: ...area that is convenient to both solution injection point and electrical supply LMI Series E7 metering pumps have corrosion resistant housings but should not be subjected to continuous high temperatur...

Страница 4: ...is little or no resistance back pressure the velocity of the pumped fluid will be so great as to cause over pumping Be cause of this characteristic back pressure equal to approximately 25 psi 1 7 Bar...

Страница 5: ...After installation is complete and an initial approximation setting has been made the pump should be calibrated and the stroke frequency and or stroke length settings adjusted F Nominal output and pre...

Страница 6: ...lume of 500 ml or more C Turn pump to internal mode with speed knob set at 100 and operate until air is exhausted from suction line and pump head D Turn pump off and note solution level in graduated c...

Страница 7: ...ump by turning the inner section of the knob counter clockwise Position the outer section of the knob so that the pointer aligns with zero on the nameplate Push down on the outer section of the knob a...

Страница 8: ...ockwise rotation until motion stops Reset knob by grasping the knob and pulling it towards you Pry the yellow cap off of the knob Place the knob on a flat surface Using needle nose pliers squeeze the...

Страница 9: ...iquifram setting is not correct restart pump then screw the Liquifram in or out Always stop pump electrically when checking Liquifram setting Repeat procedure if necessary After Liquifram is set prope...

Страница 10: ...10 3 0 EXPLODED VIEW 28 29 29 30 27 26 25 24 23 31 33 41 34 32 42 37 1718 D_306 indd 10 4 4 06 1 21 49 PM...

Страница 11: ...5839 Spacer 3 0 1 28 E7 10973 Shaft Seal 1 29 E70 E71 E72 E73 10598 Screw 10 24 S S 4 E74 10598 Screw 10 24 S S 8 30 E7 25452 Label 1 31 E7 31542 Nameplate 1 32 E70 E71 32465 Stroke Dial 1 E72 32466 S...

Страница 12: ...on Roy All Rights Reserved Printed in USA Specifications subject to change without notice Replaces same of Rev C 10 97 1718 D 3 06 201 Ivyland Road Ivyland PA 18974 USA TEL 215 293 0401 FAX 215 293 04...

Отзывы: