4.6 Dimensions
The sensor can be mounted with either M8 or 5/16" hardware. Provision to adjust the
position and orientation of the sensor to align its laser plane with the laser planes of the
other sensors in the ring is recommended. Although this alignment is not required for
reliable profile data (adjacent sensors typically scan during different time slices), aligned
laser planes provide a better appearance to the end user of the system. The laser fan is
emitted through the clear center window. The cameras are located behind the two end
red tinted windows. When mounting the sensor, ensure that there are no obstructions
between the camera windows and the Scan Zone.
4.7 FOV Envelope
The following drawings detail regions in front of the sensor that should be kept free of
obstructions. These regions envelope the laser fan projection and the two cameras view
of the scan zone. Note that intermittent blocking of one or the other camera views will
not cause loss of data as the other camera will fill in the blocked scan zone.