1.To ensure safe operation
,
profile and back side of the cookers
should be keep away from combustible (wall surfaces, etc.) no
less than 15 cm, and if it have hanging objects above, must keep
the distance above 100 cm between boiler face and hanging
objects .
2. Stoves should be installed at the air circulation place as far as
possible, and should have good indoor air circulation need to
install gas fan (or range hood) if necessary.
3. When install embedded stoves to the cupboard, must to hole
an aspirail on it profile or underneath convenient place ensure
that air free inflows.
4. After make sure the installation position of stove, make the
hole on the the cupboard as below, there are two kinds of
models. After that put the stove should be embedded in the hole.
Necessity to allow disconnection of the appliance from the
supply after installation
The disconnection may be achieved by having the plug accessible
or by incorporating a switch in the fixed wiring in accordance with
the wiring rules
The instructions specify that a board is to be installed underneath
the hob.
Minimal size of the openings of ventilation and their correct
measure: 30mm (Max. 75 mm)