Livith EASY SPIN Скачать руководство пользователя страница 26

26 

Remember that if the designer or the installer checks the need to change the frequency of the checks, 

reducing the time between them, he has the right to intervene with a specific note respectively in the 

Roofing Technical Paper or in the Installation File. Livith recommends to always contact a qualified 

technician or Livith SpA in case of extraordinary maintenance of the device. 

Livith declines all responsibility due to the system reuse following a fall if a complete 

maintenance operation has not been carried out.

The ordinary maintenance procedure for the fall arrest systems shown in this Manual is illustrated below:

DOCUMENTATION AVAILABLE

CHECKS TO BE CARRIED OUT

NON-RECOVERABLE DOCUMENTATION

CHECKS TO BE CARRIED OUT

MAINTENANCE PROCEDURES

MAINTENANCE PROCEDURES

DOCUMENTATION NOT AVAILABLE 

OR PARTIALLY AVAILABLE

RETRIEVED

DOCUMENTATION

Clean and waterproof 

the membrane 

Replace damaged/deformed 

components. 

Ask for replacement labels

of marking 

View and proceed following 

the product maintenance sheet 

that can be downloaded from 

the website www.livith.it 

or by contacting Livith S.p.A.

Con

tact

Livith S.

p.A.

C

Livith S.

p.A.

Contact

Livith S.

p.A.

Retrieve the work File (Roofing Technical Paper, 

Installation File, User and Manteinance Manuals of all 

devices)

Consult all documentation to know the 

system and the specific maintenance 

procedure

Visually inspect the devices and the 

coverage parts where they are placed

Wear and presence of corrosion of device components

Abnormal deformations of the rope or of the device components

Deformation/integrity of the fall arrest indicator

Identifiability of components through the marking

Inspect the devices and all their 

components with specific instruments 

(e.g. torque wrench)

Revise and maintain the basic structures 

and anchors as indicated in the 

Installation Sheet and/or in the Roofing 

Technical Paper.

Control the correct assembly of the system. 

Verify the efficiency of possible moving parts.

Provide for adequate report of the 

intervention carried out

Replacement of anchor devices 

and new certification

Waterproofing in the housing area of the device

Presence of water infiltrations or dips due to possible stagnations

Presence of woodworms, molds and state 

of cleanliness/degradation of the device area

Or access to 

smart.livith.it

and use the 

QRCODE SMART

to download the included documents 

Trace back to the 

installer/designer/producer using 

the marking and the partial 

documentation available 

Con

tact

If the system has been registered with 

SMART access to 

smart.livith.it 

frame the 

QRCODE 

and confirm the inspection of the system

Take note of the date of intervention on 

the roof access plaque, in the "last 

inspection date" space and indicate the 

next scheduled maintenance date in the 

"next inspection date" space

Release the documentation of the 

maintenance carried out 

in the appropriate spaces 

of the Installation File

DOCUMENT COGNITIVE 

PHASE 

ADDITIONAL TIPS

PHASE OF VISUAL 

INSPECTION OF THE SYSTEM

PHASE OF 

INSTRUMENTAL / FUNCTIONAL 

INSPECTION OF THE SYSTEM

DOCUMENTARY

FULFILMENTS

Содержание EASY SPIN

Страница 1: ...MANUAL EASYSPIN FLEX MULTIFLEX MULTISPIN RIGID RIGIDFLAT SMARTRING VERTICAL VERTICALF GRUVY GRUVYFLAT WWW LIVITH IT...

Страница 2: ...2...

Страница 3: ...W LIVITH IT INDEX 07 12 15 17 27 10 16 14 25 INSTALLATION GUIDE ACCESS PLATES SYSTEM PERFORMANCE ASSISTANCE FALL INDICATOR MAINTENANCE GUIDE PPE USE GUIDE DEVICE CERTIFICATES WARRANTY TERMS AND CONDIT...

Страница 4: ...4...

Страница 5: ...correct performance of the product these operations or to the use of the components of the devices in an improper way and not in compliance with the indications of this manual and of the product assem...

Страница 6: ...ust be equipped with PPE and connection devices equipped with an energy absorber or other components compliant with UNI EN 355 2003 aimed at limiting the dynamic force of fall arrest within 6kN Use by...

Страница 7: ...poor capacitytoabsorbloadsbyload bearingstructuresintendedtohousetheanchoring devices For any assistance in this regard go to the website www livith it This manual contains instructions intended to in...

Страница 8: ...suitably designed according to current standards The installation of the anchoring devices must be carried out away from high voltage cables electrical systems and must not have connections with them...

Страница 9: ...0 6 6 11 0 VERTICAL 7 8 10 4 VERTICAL F H30 7 0 VERTICAL F H40 6 3 GRUVY 9 0 GRUVY FLAT 9 0 See chapter regarding system performance on page 10 Type A devices offer all the performance characteristics...

Страница 10: ...ors deformable in the event of a fall For all non deformable Livith devices check with the forces indicated on page 9 of this Manual considering the device in its undeformed configuration and the stre...

Страница 11: ...ormed height mm 240 The presence of rigid elements such as slabs or wooden joists in the roofing package can prevent deformation of the anchor In this case it is advisable to consider the undeformed h...

Страница 12: ...TE enter the installation date In NEXT INSPECTION DATE enter the date of the next scheduled inspection Similarly in the event of a subsequent MAINTENANCE WORK fill in the nameplate again as follows In...

Страница 13: ...ster the system At the scheduled deadlines the client and installer will automatically receive an email alerting on the need to renew maintenance Oncethesystemisactivated evenunregistereduserswillbeab...

Страница 14: ...F and Easy Spin Livith devices are equipped with a fall indicator After installing the devices and before each use check the integrity of the fall indicator according to the example schemes shown belo...

Страница 15: ...apid deterioration if in synthetic fiber GUIDED ROPE TYPE Air draft variable with the length of the device Risk of pendulum effect Rapid deterioration of the textile fiber rope Reduced ergonomics due...

Страница 16: ...o not contribute in any way to modify or compromise the operation and durability of the devices Theinstallermustreleaseacopyoftheinstallationdocumentationtothecustomer In this regard in order to facil...

Страница 17: ...fic product sheets Livith S p A certifies that the anchoring devices Has been created designed realised and tested in compliance with the rules EN 795 2012 UNI 11578 2015 TYPE A LIVITH S p A EASYSPIN...

Страница 18: ...cal documentation included in the specific product sheets Livith S p A certifies that the anchoring devices Has been created designed realised and tested in compliance with the rules EN 795 2012 CEN T...

Страница 19: ...p A certifies that the anchoring devices Has been created designed realised and tested in compliance with the rules EN 795 2012 CEN TS 16415 2013 UNI 11578 2015 TYPE A LIVITH S p A MULTISPIN Certifica...

Страница 20: ...gned realised and tested in compliance with the rules EN 795 2012 UNI 11578 2015 TYPE A LIVITH S p A RIGID RIGID PIATTO Certificate of Conformity Via Berchet 11 35131 Padova PD P I e C F 06496100485 C...

Страница 21: ...ivith S p A certifies that the anchoring devices Has been created designed realised and tested in compliance with the rules EN 795 2012 UNI 11578 2015 TYPE A LIVITH S p A SMARTRING Certificate of Conf...

Страница 22: ...realised and tested in compliance with the rules EN 795 2012 CEN TS 16415 2013 UNI 11578 2015 TYPE A LIVITH S p A VERTICAL Certificate of Conformity Via Berchet 11 35131 Padova PD P I e C F 0649610048...

Страница 23: ...vith S p A certifies that the anchoring devices Has been created designed realised and tested in compliance with the rules EN 795 2012 UNI 11578 2015 TYPE A LIVITH S p A VERTICAL F Certificate of Conf...

Страница 24: ...certifies that the anchoring devices Has been created designed realised and tested in compliance with the rules EN 795 2012 UNI 11578 2015 TYPE A LIVITH S p A GRUVY GRUVY PIATTO Certificate of Conform...

Страница 25: ...upport structure with the involvement of a qualified technician the maintenance technician must issue a declaration of correct execution of the required maintenance intervention Extraordinary Maintena...

Страница 26: ...ar and presence of corrosion of device components Abnormal deformations of the rope or of the device components Deformation integrity of the fall arrest indicator Identifiability of components through...

Страница 27: ...s related to parasitic stresses of the device due to the lack of protection of the device from exceptional loads such as snow overload System malfunctions or deterioration of its components due to fai...

Страница 28: ...Livith SpA Headquarters Via G Berchet n 11 Padua info livith it WWW LIVITH IT Operational unit Via Adige n 2 50052 Montespertoli FI 39 0571 606160...

Отзывы: