background image

Components:

Hand wand 

– placed in the side pocket (outside LAF arm/RAF arm), controls all motors and functions (reclining, 

power headrest, lifting, etc.) via a direct connection with motors. . 

AC wall plug 

– connects the power transformer to the power outlet.

DC cord 

– connects the power transformer to the DC socket (mounted on the rear bottom of LAF arm/RAF arm 

stump).

DC socket 

– receives power from DC cord then transfer to motors.

Power Transformer 

– A box-shaped unit to transfer 110V AC power to 25V DC power to supply for the furniture.

Junction Box 

– splitter/extension cord connecting the power transformer to multiple motors/air baddders/heat padding/

hand wand.

Seat / backrest / Headrest Motor 

– motors mounted on mechanism to drive movement on seat/headrest via hand wand 

control.

Battery- 

The battery was mounted at the top of transformer and could provide the power while can't get power.

Air Bladders- 

mounted inside lower section of back, inflate the air bladders via hand wand control. Turns off 

automatically after 30 minutes of use as safety feature.

Heating pad 

– mounted inside lower section of back, produces heat via hand wand control. Turns off 

automatically after 30 minutes of use as safety feature.

Содержание 267666

Страница 1: ...1910 SEVILLE POWER RECLINER LIFT CHAIR W AIR MASSAGE USER MANUAL...

Страница 2: ...to supply for the furniture JunctionBox splitter extensioncord connecting the power transformer to multiple motors air baddders heat padding hand wand Seat backrest Headrest Motor motors mounted on me...

Страница 3: ...lugged in 2 Broken side switch 3 Broken DC socket 4 Broken power transformer especially when ALL motors stops working on one unit 5 Power cords damaged 6 Motors failure NOTE In some cases a button on...

Страница 4: ...Instruction for hand wand...

Страница 5: ...d If the HEAT button is illuminated but the heat pad is not producing heat the heat pad could have become disconnected 1 Unplug the piece of furniture from the wall outlet 2 Wait at least 30 seconds 3...

Страница 6: ...buttons will open and close the recline position Lumbar buttons will open and close the lumbar air cushion The Footrest and Lift buttons both control a single actuator that will lift or lower the cha...

Страница 7: ...s not show movement If a Headrest Footrest Back Lumbar Lift Home button is pressed and no motion occurs the Hand Control could be in a lock out state 1 Wait for at least 10 seconds and press the butto...

Страница 8: ...ft the back panel to reveal zipper pouch 4 Unzip pouch to reveal the Junction 5 Locate the Headrest motor cord shown below 6 Ensure that there are no frayed exposed or otherwise damaged wires Do not c...

Страница 9: ...t pinched or otherwise blocked 8 Ensure that the air hoses are not damaged in anyway 9 Zip the pouch and reset the back panel 10 If the Lumbar air cushion still does not inflate control your furniture...

Страница 10: ...be turned off at any time by pressing the PWR button The Air Massage mode can be changed by pressing the MODE button There are three massage modes Alternate Pulse and Wave The Air Massage will always...

Страница 11: ...maged 1 Unplug the piece of furniture from the wall outlet 2 Wait at least 30 seconds 3 Lift the back panel to reveal zipper pouch 4 Unzip pouch to reveal the Junction 5 Locate the air hose connectors...

Страница 12: ...POWER RECLINER PARTS...

Страница 13: ...cable Check connection security and integrity of motor s 2 pin cable 1 Check power cords integrity and connection to transformer 2 If power cords undamaged and connection secured replace power transfo...

Отзывы: