background image

 



Thermoflow 

Installation Guidelines and Operating Instructions 

June 2015 

  

 

 
 
 
 
 
 

Technical details subject to change 

Please ensure you have the latest specifications

 

 

 

 

 

Living Flame    

Auckland 

Display & Head Office:  343b Church Street, Penrose 

Phone:  09 622 1148    Fax:  09 622 1179 
Email:    [email protected] 

www.livingflame.co.nz 

Содержание Thermoflow

Страница 1: ...ctions June 2015 Technical details subject to change Please ensure you have the latest specifications Living Flame Auckland Display Head Office 343b Church Street Penrose Phone 09 622 1148 Fax 09 622...

Страница 2: ...Living Flame Thermoflow Fireplace Installation Instructions Page 2 Living Flame 2012...

Страница 3: ...g Instructions Electronic Control 12 Operating Instructions Electronic with Variable Remote Control 13 Living Flame Expressed Guarantee 14 Living Flame Expressed Guarantee contd 15 Annual Safety Servi...

Страница 4: ...Architect Builder Diagram Flue Height Diagram 36 Gasfitter Architect Builder Diagram Flue Off Set Rules 37 Gasfitter Architect Builder Diagram Flue Height Cowl Clearance 38 Gasfitter Gas Connection Ga...

Страница 5: ...ing Flame Expressed Guarantee 14 Living Flame Expressed Guarantee contd 15 Annual Safety Service 16 Inspection Service on New Installations What you need to know Installation Instruction Guidelines Li...

Страница 6: ...ified Installation Unique Living Flame Diffuser Burner fire Glowing coals logs and embers No products of combustion Co2 Co No2 into the room Natural convection Totally clean room air No added moisture...

Страница 7: ...nd dust cover 50mm clearance required Flue Clearance 25mm to any combustible material Colour Black Effect Fixed Logs Coals and Embers Special Custom Sizes for a Thermoflow Thermoflow gas convector fir...

Страница 8: ...utoff valves are located What to do if you smell Gas Open windows Do not try to light any gas appliance Do not use any electrical appliance or switches Do not use the telephone in your home Turn off t...

Страница 9: ...knob depressed for approximately ten seconds until the pilot remains alight when the control knob is released NOTE If the gas line has been interrupted when first lighting the fire it may be necessar...

Страница 10: ...terrupted when first lighting the fire it may be necessary to follow the start up sequence several times High Low Flame Turn the control knob to light the main burner Small Flame Diagram is low Large...

Страница 11: ...as line has been interrupted when first lighting the fire it may be necessary to follow the start up sequence several times High Low Flame Once the fire is fully glowing and maximum temperature has be...

Страница 12: ...is off the flame will come on in the high position A single beep will confirm the reception of the command Room Thermostat The Remote can operate as a room thermostat The thermostat can be set to a d...

Страница 13: ...control part where an irreparable defect due to material or manufacturing failure occurs within the first year from date of supply by Living Flame One Year Labour Cover This is a One Year Guarantee co...

Страница 14: ...hen completed by a Living Flame approved serviceperson in accordance with Living Flame procedures Operating Living Flame Fireplaces must be operated in accordance with Living Flame Operating Instructi...

Страница 15: ...ck Complete Assembly Test Flue Vent System Check Complete Operation of the Fire Final Clean and Dust Re light all Other Gas Appliances Re demonstrate Fireplace to ensure owner has full understanding o...

Страница 16: ...and operating correctly and safely Our Technical Inspection Team inspects every aspect of your fireplace installation Location Building and Finishing is correct Electrical Connections Switching and O...

Страница 17: ...imum amount of gas used Gas is the most environmentally friendly of all the fossil fuels and will continue to play a large part in our lives well into the future Quality Assurance Living Flame is prou...

Страница 18: ...Living Flame Thermoflow Fireplace Installation Instructions Page 18 Living Flame 2012 Notes...

Страница 19: ...Lines 26 Clearance for Combustible Mantel What you need to Know Installation Instruction Guideline Living Flame Thermoflow Gas Fireplaces must be installed in accordance with these guidelines For saf...

Страница 20: ...firebox hood and dust cover 50mm clearance required Flue Clearance 25mm to any combustible material Colour Black Effect Fixed Logs Coals and Embers Special Custom Sizes for Thermoflows Thermoflow gas...

Страница 21: ...nt Elevation Flue Dimensions Fire Size A Flue Inner B Flue Liner 0450 0500 0550 0600 0650 150mm diameter 200mm diameter 0700 0750 175mm diameter 225mm diameter 0800 0850 200mm diameter 250mm diameter...

Страница 22: ...Living Flame Thermoflow Fireplace Installation Instructions Page 22 Living Flame 2012 Owner Gasfitter Architect Builder Dimensions Side Elevation...

Страница 23: ...Living Flame Thermoflow Fireplace Installation Instructions Page 23 Living Flame 2012 Owner Gasfitter Architect Builder Dimensions Plan View...

Страница 24: ...tions Page 24 Living Flame 2012 Owner Gasfitter Architect Builder Trim Out Firebox Clearances Hearth Regulation Hearth Hearth to be of non combustible material Hearth Size Minimum of 300m from front o...

Страница 25: ...stible Mantel outside 15 line from top of the firebox Otherwise non combustible Mantel may be located minimum 20mm 50mm Minimum Clearance from top of Hood Dust Cover to First Lintel Hood Dust Cover Si...

Страница 26: ...ng Flame 2012 Owner Gasfitter Architect Builder Clearance for Combustible Mantel 15 450mm Vertical Clearance Top of Fire Underside of Mantel Selected Combustible Mantel outside 15 line from the top of...

Страница 27: ...t Rules 37 Gasfitter Architect Builder Diagram Flue Height Cowl Clearance 38 Gasfitter Gas Connection Gas Supply Test Pressures 39 Gasfitter Testing Controls Ventilation 40 Gasfitter Installation of L...

Страница 28: ...iteria as above but with the old firebricks removed from the fireplace and the bottom levelled to accommodate the fire 6 Thermoflow fires built into new locations with flues require a gas supply of 60...

Страница 29: ...system needed for a particular fireplace installation be confirmed before installing takes place For example Manual Control Electronic Control and Remote Control Before Booking the commissioning of a...

Страница 30: ...also be made for any cabling required if electronic or solenoid control options are to be taken Install the fire into position level and fix Connect a 10mm gas line from the rear of the fireplace to...

Страница 31: ...id into place to check for size levels and fixing The firebox may be fixed by its own front flanges or by side fixings under the front sloping vent Connect a gas line from the rear of the fireplace to...

Страница 32: ...t access for safe operation and maintenance Where there is a flat and level surface Where there is sufficient flue vent clearance around the flue in relation to doors or windows Where there is access...

Страница 33: ...d its air space liner will be at least 25mm clear of any combustible material A minimum clearance of 25mm is required between the flue and air space liner where it penetrates the ceiling A suitable fl...

Страница 34: ...the roof to protect flashings Flue in the high wind areas needs to have the inner and outer flues sealed and should be stayed A false chimney is recommended Clearances Clearances from the flue to the...

Страница 35: ...Living Flame Thermoflow Fireplace Installation Instructions Page 35 Living Flame 2012 Gasfitter Architect Builder Flue Height Diagram Flue Clearance...

Страница 36: ...Living Flame Thermoflow Fireplace Installation Instructions Page 36 Living Flame 2012 Gasfitter Architect Builder Flue off Set Rules...

Страница 37: ...Living Flame Thermoflow Fireplace Installation Instructions Page 37 Living Flame 2012 Gasfitter Architect Builder Flue Height Diagram Cowl Clearance...

Страница 38: ...tion mounted at the bottom right hand side of the fireplace as seen from the front A gas line capable of supplying a minimum of 50MJ h should be brought to the fireplace with a 10mm soft copper tail T...

Страница 39: ...vided in accordance with ASNZS5601 and Manufacturers Instructions This fireplace has also been designed to draw room air into the fireplace and to circulate it as convected heat The blocking up or mod...

Страница 40: ...he diffuser blanket and scatter a handful of embers lightly over the bed to cover the diffuser blanket Fill the channel at the front and rear of the burner blanket completely with embers Place the fix...

Страница 41: ...iving Flame Thermoflow Fireplace Installation Instructions Page 41 Living Flame 2012 Gasfitter Architect Builder Flue Components Spigot Plate Cowl and Windskirt Fully Adjustable Bend Bracket and Strap...

Страница 42: ...Living Flame Thermoflow Fireplace Installation Instructions Page 42 Living Flame 2012 Notes...

Страница 43: ...AIS Sigma Gas Valve SIT 843 Wiring Layout Pilot Low Flame High Flame What you need to know Installation Instruction Guideline Living Flame Thermoflow Gas Fireplaces must be installed in accordance wit...

Страница 44: ...iving Flame Thermoflow Fireplace Installation Instructions Page 44 Living Flame 2012 Electrician Fan Wiring On Off Brown Phase 230 V Ac Green Earth Blue Neutral Convector Fan Fan Cable and Plug On Off...

Страница 45: ...Living Flame Thermoflow Fireplace Installation Instructions Page 45 Living Flame 2012 Electrician Internal Fireplace Power Plugs...

Страница 46: ...Testing Lead Lamp Earth 2 Amp Fuse Isolator On Off Switch Hi Low Switch Fan Switch Black Cable Grey Cable White Cable Sockets at Fireplace Plug in at Fireplace Test Lamp 230 VAC and Plug Testing each...

Страница 47: ...Gas Valve SIT Wiring Layout Pilot Low Flame High Flame Gas In Pressure Power Plug Hi Low Plug Flame Sensor SparkElectrode Hi Low Coil High Low Din Plug Black Cable Gray Cable Main Control Valve Din Pl...

Страница 48: ...00 R15 D5 00 AGA6953 Sigma Gas Valve SIT 843 Wiring Layout Pilot Low Flame High Flame Hi Low Plug Flame Sensor Spark Electrode High Low Din Plug Black Cable Gray Cable Gas InPressure E N A FLAME SENS...

Страница 49: ...Living Flame Thermoflow Fireplace Installation Instructions Page 49 Living Flame 2012 Notes...

Страница 50: ...iving Flame 2012 Living Flame Auckland DISPLAY CENTRE 343b Church Street Penrose Auckland POSTAL ADDRESS PO Box 12964 Penrose Auckland 1642 TELEPHONE 64 9 622 1148 FAX 64 9 622 1179 EMAIL info livingf...