57
EN
You must ensure that a windproof cowl should be
fi
tted which complies with the standards in forc
e.
Fireplace flue gas
Avoid contact with combustible materials (example:
wooden beams) and in any case provide for their
insulation with
fl
ame retardant material. In case of pipe
penetrations through roofs or walls is recommended
to use special kits crossing, certi
fi
cates, are available
commercially. In the event of a chimney
fi
re, turn off
the stove, disconnect from the network and never
open the door. Then call the authorities.
The chimney cap
The chimney cap must respect the following
requirements:
• It must have the equivalent diameter and internal
form of th
e fl
ue.
• It must have a useful outlet diameter of not less
than double that of th
e fl
ue.
• The chimney cap on the roof or that remains in
contact with the outside (for example, in case of
open lofts or attics), must be covered with elements
in brick or tile and must, in any case, be well insulated.
• It must be constructed to prevent rain, snow, and
extraneous bodies from entering the
fl
ue and so
that the discharge of the products of combustion is
not inhibited by wind from any quarter or strength
(wind-proof chimney cap).
• The chimney cap must be positioned in such a way
as to guarantee the adequate dispersion and dilution
of the products of combustion and in any case, must
be out of the re
fl
ux zone. This zone has different
dimensions and forms according to the angle of
inclination of the roof so it is necessary to adopt
minimum heights (Fig. 2).
• The chimney cap must be a wind-proof type and
must be above the ridge.
• Eventual structures or other obstacles that are
higher than the chimney cap must not be too close
to the chimney cap itself.
• The device should not be installed in the
fl
ue
shared.
Fig. 5: Characteristics of chimney
YES
NO
40 cm
150 cm
40 cm
20 cm
20 cm
100 cm
Distance to objects
It is also recommended to keep the pellets and all
fl
ammable materials at a suitable distance from the
stove.
Flammable walls and materials
Non-flammable walls and material