12
an open circuit or Low Resistance (LO). Maximum resistance to
detect continuity is 250 Ohms.
▪
Resistance Mode measures and displays resistance between
input probes.
The display shows real-time input unless you press Hold or Min/Max.
When input exceeds your presently selected range, the letters OL
(overload) appear. When your input is out of range or over 60V (AC or DC),
the high voltage warning sign appears, alerting you to a potentially
hazardous voltage.
All DMM modes display a bar graph that approximates the percent of the
full range of the function selected.
Common Voltage Mode Functions
The following common voltage mode functions are used when DC Voltage,
AC Voltage, or Low Impedance have been selected (see above).
▪
Hold (freezes display at current measurement)
▪
Press the
Hold
soft key to freeze the display. The word Hold
appears in red on the screen.
▪
Press the
Hold
soft key to resume real time measurement.
▪
Range (manually select a
Range
or use the automatic range Auto
Range). The range is displayed to the lower right of the measurement.
▪
Press the
Range
soft key repeatedly to cycle through Manual
Range options or Auto Range.
▪
Auto Range is the default. Ranges available are: 0-4V, 0-40V,
0-400V, and 0-600V.
▪
Min/Max (displays maximum and minimum values, as well as
average value)
▪
Once range and the desired voltage measurements have been
selected, press the
Min/Max
soft key to display minimum/
maximums. If a new high or low measurement is encountered, the
Min/Max display changes.
▪
To display an average measurement, press the
Average
soft key
(which changes to Min/Max). An average value will be displayed
and change according to continuing real-time input.
▪
Press the
Hold
soft key to freeze the display. The word HOLD will
appear on the screen in red.