CHAPTER 2: ENGINEERING MODE

 

2.1 Engineering Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)    To enter Engineering Mode, press & hold the INCLINE UP and SPEED DOWN

 

keys at the same time for 3-5 seconds 

until Engineering Menu appears on the display. 

 

2)    Use the INCLINE or SPEED UP and DOWN keys to scroll through a list of parameters.   

   

3)    Press CHANGE DISPLAY / ENTER to enter a parameter setting.     

 

4)    Use the INCLINE or SPEED UP and DOWN keys to change the parameter.     

 

5)    Press the ENTER key to save the change to the parameter.     

 

6)  Press and hold the STOP key to exit Engineering Mode and return to normal operation. 

 

 

 

Содержание LS13.0T-02

Страница 1: ...1 LS13 0T 02 Service Manual...

Страница 2: ...ode Overview 5 CHAPTER 3 ELECTICAL DIAGRAM 3 1 Electrical Diagram 6 CHAPTER 4 TROUBLESHOOTING 4 1 Troubleshooting No Power to the Console 7 4 2 Troubleshooting Keypad Not Responding 9 4 3 Troubleshoot...

Страница 3: ...3 CHAPTER 1 SERIAL NUMBER LOCATION 1 1 Serial Number Location...

Страница 4: ...u appears on the display 2 Use the INCLINE or SPEED UP and DOWN keys to scroll through a list of parameters 3 Press CHANGE DISPLAY ENTER to enter a parameter setting 4 Use the INCLINE or SPEED UP and...

Страница 5: ...TART key to select unit 1 KM 0 Mile on TIME window Use the ENTER CHANGE DISPLAY key to enter the languages selection and to select a language 0 English 1 Germany 2 Dutch 3 French on TIME window ENG 4...

Страница 6: ...6 CHAPTER 3 TROUBLESHOOTING 3 1 Electrical Diagram...

Страница 7: ...ee if the power switch is lit If it is not try a different outlet a If the power switch still does not light up with a known good outlet replace the power switch 2 Check to see if the MCB has power Th...

Страница 8: ...the 15V Pin Pins 7 8 DC output is normally around 15VDC If there is no output replace the MCB b If output is around 15VDC check the console cable for pinches or kinks If any damage is found replace t...

Страница 9: ...ering Mode a Use the LEVEL UP or DOWN key to scroll to ENG0 and press ENTER b Test each of the keypads using Display Test The console should chime as each key is pressed 2 If any keypads are not chimi...

Страница 10: ...if the data in windows TIME and DISTANCE changes the console is ok If the data does not change replace the UCB 3 Turn off the power switch and open the upper motor cover Remove the red black wires com...

Страница 11: ...key and then the START key a Press the INCLINE UP and DOWN keys b You should be able to hear beeps from the two relays on the MCB as the incline motor engages If these relays can be heard the MCB is...

Страница 12: ...on something 7 The air shock needs lubrication 8 The incline motor is missing washers or needs lubrication Solution 1 This noise is from the roller or running belt a If this is a new unit some noise...

Страница 13: ...rame b Check the deck shocks for deterioration or crumbling Replace if needed c Check to see if the air shock is making this noise lubricate or replace if needed 6 This sound is likely due to the belt...

Страница 14: ...aker wire are defective 7 There is a grounding issue with the earphones or console Solution 1 One of the speaker boards has a bad connection or is faulty a Check the connection of the wires going from...

Страница 15: ...he IPod dock at the console c Replace the IPod dock 5 Speakers are not getting a clear signal through the speaker wires a Check the speaker wire connections b Check for any kinks or cuts in the speake...