Little Giant WGFP-50 Скачать руководство пользователя страница 1

1

E N G L I S H

ENGLISH

EN

This instruction sheet provides you with the information required 
to safely own and operate your Little Giant pump. Retain these 
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality 
workmanship and material, and has been engineered to give you 
long and reliable service. Little Giant pumps are carefully tested, 
inspected, and packaged to ensure safe delivery and operation. 
Please examine your pump carefully to ensure that no damage 
occurred during shipment. If damage has occurred, please 
contact the place of purchase. They will assist you in replacement 
or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE 
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR 
LITTLE GIANT PUMP. KNOW THE PUMP’S APPLICATION, 
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 
INFORMATION. FAILURE TO COMPLY WITH THESE 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!

DESCRIPTION

This pump has been designed to operate in applications such 
as waterfalls, streams, and fountainheads. It can also be used to 
circulate the water in your pond. Unique features of this pump 
include a non-clogging vortex impeller, auto-resetting thermal 
overload protection, stainless steel motor housing, and the ability 
to pass solids with diameters up to 1.18”/30mm (WGFP-50) or 
1.38”/35mm (WGFP-75, WGFP-100, WGFP-150, and WGFP-200).
CAUTION: To prevent damaging the pump, do not pump 
abrasives such as sand or mud.

SAFETY GUIDELINES

Read all instructions and Safety Guidelines thoroughly. Failure 
to follow the guidelines and instructions could result in serious 
bodily injury and/or property damage.
RISK OF ELECTRICAL SHOCK: This pump is supplied with a 
grounding conductor and grounding-type attachment plug. To 
reduce the risk of electric shock, be certain that it is connected 
only to a properly grounded, grounding-type receptacle. A 
separate branch circuit is recommended. Do not remove the third 
prong from the plug. 

RISK OF ELECTRICAL SHOCK: This pump has not been certified 
for use in swimming pool areas where people are present in the 
water. Therefore, pump must not be used for this purpose.
WARNING: Do not use to pump flammable or explosive fluids 
such as gasoline, fuel oil, kerosene, etc. Pump should only be 
used with liquids compatible with pump component materials. 
Failure to follow this warning can result in property damage, 
personal injury, or death.
The pump motor is equipped with an automatic resetting thermal 
protector and may restart unexpectedly.
Do not handle a pump or pump motor with wet hands or when 
standing on a wet or damp surface, or in water. Do not stand 
in water while changing fuses or insert your finger into the fuse 
socket.
Make certain the unit is disconnected from the power source, all 
liquids are drained, and all pressure released within the system 
before attempting to service the pump.
This appliance has no user-serviceable parts. The motor housing of 
the pump is completely sealed and requires no service. Disassembly 
of the motor housing or alteration of the power cord will void all 
warranties. The power cord on these units cannot be replaced.
Conformity with local and state electric codes is mandatory. The 
National Electric Code requires that a ground fault circuit interrupter 
(GFCI) be used in the branch circuit supplying sump, utility, effluent 
and all fountain pumps, pool pumps and other pond equipment.
All wiring and electrical work should be done by a qualified electrician.
An acceptable motor control switch shall be provided at the time 
of installation.
Secure the discharge line before starting the pump. An unsecured 
discharge line will whip, possibly causing personal injury and/or 
property damage.
Do not run the pump dry. It is designed to be cooled by the fluid it 
moves. If the pump is run dry it will become dangerously hot, and 
could cause personal injury and/or damage to the pump.
The pump’s motor housing or gear chamber contains a dielectric 
oil to aid in bearing lubrication and motor heat dissipation. This 
oil is non-toxic to aquatic life, however suffocation can occur if oil 
is left on the water surface. If oil escapes, it can be removed from 
the surface quickly by placing newspapers on the water surface to 
soak up the oil.
Do not lift or carry the pump by the power cord. Use the handle 
on top of the pump.
Adhere to the guidelines of the National Electric Code (NEC) or 
Canadian Electric Code (CEC) and any other national, state, and 
local electric, plumbing, and building codes for ALL installations. 
Check with the appropriate agencies or a water systems 
professional for information. The installation of this product must 
be in accordance with applicable regulations.

MODELS 

MODèLES 

MODELOS

 WGfp-50 • WGfp-75 • 

WGfp-100 • WGfp-150 •  

WGFP-200

Franklin Electric Co., Inc.

Oklahoma City, OK 

1-888.856.0000 Fax: 1-405.440.1469

www.lg-outdoor.com

[email protected]

MODEL 

NO.

CATALOG 

NO.

DISCH. 

SIZE

HP

PH VOLTS HZ AMPS WATTS

WGFP-50

566068

2” FNPT

1/2

1

115

60

7

590

WGFP-75

566069

2” FNPT

3/4

1

115

60

8

847

WGFP-100

566070

2” FNPT

1

1

115

60

12

1210

WGFP-150

566071

3” FNPT

1-1/2

1

115

60

11

1210

WGFP-200

566072

3” FNPT

2

1

230

60

9

2085

Table 1 • Tableau 1 • Tabla 1

Содержание WGFP-50

Страница 1: ...ng thermal protector and may restart unexpectedly Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface or in water Do not stand in water while changing fuses or...

Страница 2: ...OC DER L INSTALLATION L UTILISATION OU L ENTRETIEN DU PRODUIT LITTLE GIANT SE FAMILIARISER AVEC LES APPLICATIONS LES LIMITES ET LES RISQUES POTENTIELS DU PRODUIT ASSURER SA PROPRE PROTECTION ET CELLE...

Страница 3: ...rement submerg e et sur une surface solide comme une brique ou une pierre pour viter son obstruction Ne jamais poser la pompe directement sur du gravier du sable ou de la terre 2 Raccorder le tuyau de...

Страница 4: ...ios da os a la persona y al equipo ADVERTENCIA Peligro de choque el ctrico Esta bomba se entrega con un cable a ras de tierra o un enchufe accesorio a ras de tierra o ambos Para reducir el riesgo de c...

Страница 5: ...ONS DIMENSIONS Dimensiones A B C WGFP 50 13 9 352 mm 8 8 223 mm 4 5 115 mm WGFP 75 14 4 367 mm 8 8 223 mm 4 5 115 mm WGFP 100 17 4 441 mm 10 3 261 mm 5 2 132 mm WGFP 150 19 0 482 6 mm 12 0 304 8 mm 6...

Страница 6: ...ique et en la secouant avec le refoulement ouvert Desconecte el cord n el ctrico Saque el aire sumergiendo la bomba en una posici n inclinada y sacudi ndola con el descarga abierto Suction screen clog...

Страница 7: ...INTO PRODUCTION CIRCULATED AND SOLD BY THE COMPANY AND OR 2 DEFECTS THAT WERE NOT FOUND AT THE TIME OF SALE DUE TO SCIENTIFIC AND TECHNOLOGICAL REASONS This Limited Warranty gives you specific legal r...

Страница 8: ...A A NINGUNO DE LOS SIGUIENTES CASOS 1 Cepillos turbina o leva en modelos con motor de cepillo y o turbinas con aleta flexible 2 Cualquier producto que no se instale aplique mantenga y utilice seg n la...