INTRODUCTION

EN

This instruction sheet provides you with the information required 
to safely own and operate your Little Giant pump. Retain these 
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality 
workmanship and material, and has been engineered to give you 
long and reliable service. Little Giant pumps are carefully tested, 
inspected, and packaged to ensure safe delivery and operation. 
Please examine your pump carefully to ensure that no damage 
occurred during shipment. If damage has occurred, please 
contact the place of purchase. They will assist you in replacement 
or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE 
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR 
LITTLE GIANT PUMP. KNOW THE PUMP’S APPLICATION, 
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 
INFORMATION. FAILURE TO COMPLY WITH THESE 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!

DESCRIPTION

This pump has been designed to operate in applications such 
as waterfalls, streams, and fountainheads. It can also be used 
to circulate the water in your pond. Unique features of this 
pump line include a non-clogging vortex impeller, auto-resetting 
thermal overload protection, stainless steel motor housing, and 
the ability to pass solids with diameters up to .98”/25mm 

 

(WGFP-33). CAUTION: To prevent damaging the pump, do not 
pump abrasives such as sand or mud.

SAFETY GUIDELINES

WARNING

Read all instructions and Safety Guidelines thoroughly. Failure to 
follow the guidelines and instructions could result in serious bodily 
injury and/or property damage.
RISK OF ELECTRICAL SHOCK: This pump is supplied with a 
grounding conductor and grounding-type attachment plug. To 
reduce the risk of electric shock, be certain that it is connected 
only to a properly grounded, grounding-type receptacle. A 
separate branch circuit is recommended. Do not remove the third 
prong from the plug. 

RISK OF ELECTRICAL SHOCK: This pump has not been certified 
for use in swimming pool areas where people are present in the 
water. Do not use the pump for this purpose.
WARNING: Do not use to pump flammable or explosive fluids such 
as gasoline, fuel oil, kerosene, etc. Pump should only be used 
with liquids compatible with pump component materials. Failure 
to follow this warning can result in property damage, personal 
injury, or death.
The pump motor is equipped with an automatic resetting thermal 
protector and may restart unexpectedly.
Do not handle a pump or pump motor with wet hands or when 
standing on a wet or damp surface, or in water. Do not stand 
in water while changing fuses or insert your finger into the fuse 
socket.
Make certain the unit is disconnected from the power source, all 
liquids are drained, and all pressure released within the system 
before attempting to service the pump.
This pump has no user-serviceable parts. The motor housing of the 
pump is completely sealed and requires no service. Disassembly 
of the motor housing or alteration of the power cord will void all 
warranties. The power cord on these units cannot be replaced.
Conformity with local and state electric codes is mandatory. 
The National Electric Code requires that a ground fault circuit 
interrupter (GFCI) be used in the branch circuit supplying sump, 
utility, effluent and all fountain pumps, pool pumps and other pond 
equipment.
All wiring and electrical work should be done by a qualified 
electrician.
Secure the discharge line before starting the pump. An unsecured 
discharge line will whip, possibly causing personal injury and/or 
property damage.
Do not run the pump dry. It is designed to be cooled by the fluid it 
moves. If the pump is run dry it will become dangerously hot, and 
could cause personal injury and/or damage to the pump.
The pump’s motor housing contains a dielectric oil to aid in 
bearing lubrication and motor heat dissipation. This oil is non-toxic 
to aquatic life. However, suffocation can occur if oil is left on the 
water surface. If oil escapes the motor housing it can be removed 
from the surface quickly by placing newspapers on the water 
surface to soak up the oil.
Do not lift or carry the pump by grasping of the power cord. 
A handle is molded integral with top housing cover for this 
purpose.

ELECTRICAL CONNECTIONS

WARNING

 1.  Check the pump label for proper voltage required. Do not 

connect the pump to any voltage other than that shown.

 2.  Plug the power cord directly into an electrical outlet.

MODEL WGFP-33

MODèLES WGFP-33

MODELOS WGFP-33

115V/60HZ

Franklin Electric Co., Inc.

Oklahoma City, OK 73127

www.lg-outdoor.com

[email protected]

MODEL 

NO.

CATALOG 

NO.

SAFETY 

LISTING

DISCH. 

SIZE

HP PH VOLTS HZ AMPS WATTS MOTOR 

TYPE

GPH @ HEAD

SHUT 

OFF

POWER 

CORD

WEIGHT 

(lbs.)

5’

10’

15’

20’

WGFP-33

566067

cCSAus

1-1/2”  

FNPT

1/3

1

115

60

5

455

PSC

2500 2000 1400 600

25’

19’

17.5

Table 1 • Tableau 1 • Tabla 1

Содержание WGFP-33

Страница 1: ...can result in property damage personal injury or death The pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly Do not handle a pump or pump motor with wet...

Страница 2: ...mpe a t con ue pour fonctionner dans des applications comme des chutes d eau des ruisseaux et des t tes de fontaines Elle peut galement tre utilis e pour faire circuler l eau des plans d eau Les compo...

Страница 3: ...n la secouant lorsque l vacuation s ouvre Desconecte el cable de energ a Elimine el aire sumergiendo la bomba en posici n inclinada y agit ndola con la descarga abierta Suction screen clogged La grill...

Страница 4: ...gura su producto Little Giant Guarde las instrucciones para referencia futura El producto Little Giant que ha adquirido se fabrica utilizando mano de obra y materiales de la m s alta calidad y ha sido...

Страница 5: ...calientes El uso ideal de esta bomba es el bombeo de agua dulce mientras est sumergida para un debido enfriamiento PRECAUCI N es obligaci n cumplir con los c digos el ctricos locales y estatales El C...

Страница 6: ...feet The Company reserves the right at any time and from time to time to make changes in the design and or improvements upon its product without thereby imposing any obligation upon itself to make co...

Страница 7: ...l n existe aucune garantie ou repr sentations autres que celles exprim es dans ce document CETTE GARANTIE ET CE RECOURS SONT EN LIEU ET PLACE DE TOUTES LES AUTRES GARANTIES ET RECOURS Y COMPRIS SANS S...

Страница 8: ...e en cualquier momento y ocasionalmente introducir cambios en el dise o y o mejoras en sus productos sin que esto imponga ninguna obligaci n de introducir los cambios o mejoras correspondientes en los...

Отзывы: