Introduction 

This instruction sheet provides you with the information required to safely own and  

operate your product. Retain these instructions for future reference.  

The product you have purchased is of the highest quality workmanship and material, and has been engineered to give you 

long and reliable service. These products are carefully tested, inspected, and packaged to ensure safe delivery and 

operation. Please examine your item(s) carefully to ensure that no damage occurred during shipment. If damage has 

occurred, please contact the place of purchase. They will assist you in replacement or repair, if required.  

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR PRODUCT. 

KNOW THE PRODUCT’S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT YOURSELF AND OTHERS BY 

OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN PERSONAL 

INJURY AND/OR PROPERTY DAMAGE! 

 

 

SAFETY GUIDELINES  

 

WARNING: 

When attaching pump leads to battery terminals, be sure that the area is adequately ventilated to prevent an 

explosion or fire from explosive or flammable vapors that may be present. Consult the battery manufacturer for additional 

safety information.  

Disconnect the pump from the power source before servicing or removing any component.  

Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in explosive 

atmospheres. Pump should only be used with liquids compatible with pump component materials.  

Do not handle pump with wet hands or when standing on a wet or damp surface or in water.  

Batteries emit explosive hydrogen gas. Avoid smoking, sparks, or open flame anywhere near the battery.  

An explosion from the battery can cause blindness. Shield your eyes when working near the battery.  

Batteries contain sulfuric acid. In case of contact with eyes, skin, or clothing, flush immediately with large amounts of 

water and get medical attention.  

Do not add acid or electrolyte to the battery.  

Keep out of reach of children.  

In any installation where property damage and/or personal injury might result from an inoperative or leaking pump due to 

power outages, discharge line blockage, or any other reason, use a backup system(s) and/or alarm.  

Support the pump and its piping when assembling and when installed. Failure to do so may cause piping to break, pump to 

fall, motor bearing failures, etc.  

 

ELECTRICAL CONNECTIONS  

 

1.

 

Check the pump label for proper voltage required. Do not connect to voltage other than that shown.  

2.

 

For proper motor protection, install a 2.0 amp fuse in the circuit.  

3.

 

When using a battery as the power source, attach the red positive (+) lead wire to the positive (+) battery terminal, 

then attach the black negative (-) lead wire to the ground (-) battery terminal. When disconnecting the pump, first 

disconnect the black negative (-) lead wire from the ground (-) battery terminal, then disconnect the red positive (+) 

lead wire from the positive (+) battery terminal.  

4.

 

Refer to Table 1 for recommended minimum lead wire sizes.  

 

OPERATION

 

 

CAUTION: 

This pump is designed for intermittent use only (15 minutes on – 45  

minutes off) with liquid no hotter than 160°F.  

CAUTION: 

The pump is cooled by pumping fluid. Do not let the pump operate dry; this can damage the seal and cause 

motor failure.  

NOTE: 

This pump is designed to operate submerged or in-line. It can be placed in any position below the water level when 

primed.  

1.

 

For proper operation, connect the pump to a steady 12-volt DC power source or a 12-volt battery in good condition. 

A low-voltage power source may cause critical overheating and premature failures. To avoid this, maintain proper 

voltage and use recommended wire size during installation (Table 1).  

2.

 

Use the hooded inlet plate for submersible operation. For in-line operation, remove the inlet plate mounting screws 

and replace the hooded inlet plate with the threaded inlet plate. Make certain that the inlet O-ring seal is installed in 

Содержание PONY 360

Страница 1: ...FNPT IP 53 Capacity 1136 LPH 31m Shut Off 14 m Discharge 19 mm Electrical 12VDC 60Hz 7 0A 165W MODEL 555203 BPLA Utility Pump Water removal from compact places such as boat bilges recreational vehicl...

Страница 2: ...not compatible with pump component materials Do not use unit in enclosed areas Intermittent duty only 15 minutes per hour SAFETY GUIDELINES WARNING Do not use to pump flammable or explosive fluids su...

Страница 3: ...of the wide variety of applications and mounting situations an inline fuse has not been permanently installed In order to provide adequate protection for the motor an inline fuse and fuse holder MUST...

Страница 4: ...Consult your local electrician for installation and availability 11 When used in a boat pump should not be installed in the bilge WARNING Disconnect battery when making adjustments and repairs First...

Страница 5: ...cemen should attempt to repair this unit Improper repair and or assembly can cause an electrical shock hazard 5 TO REPLACE IMPELLER Replace impeller when it has become worn or damaged 6 Remove cover p...

Страница 6: ...or clothing flush immediately with large amounts of water and get medical attention Do not add acid or electrolyte to the battery Keep out of reach of children In any installation where property dama...

Страница 7: ...SERVICING OR REMOVING ANY COMPONENT CAUTION The pump is permanently lubricated Oiling is not required DO NOT open the sealed portion of the pump or remove the housing screws NOTE The power leads on th...