background image

EN

INTRODUCTION

This instruction sheet provides you with the information required to safely own and 

operate your Little Giant product. Retain these instructions for future reference.
The Little Giant product you have purchased is of the highest quality workmanship 

and material, and has been engineered to give you long and reliable service. Little 

Giant products are carefully tested, inspected, and packaged to ensure safe 

delivery and operation. Please examine your item(s) carefully to ensure that no 

damage occurred during shipment. If damage has occurred, please contact the 

place of purchase. They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO 

INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PRODUCT. KNOW 

THE PRODUCT’S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. 

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD 

RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! 

SAFETY GUIDELINES

WARNING

Make certain that the unit is disconnected from the power source before 

attempting to service or remove any component.
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, 

kerosene, etc. Do not use in explosive atmospheres. Pump should only be used 

with liquids compatible with pump component materials.
Do not handle pump with wet hands or when standing on a wet or damp surface 

or in water.
This pump is supplied with a grounding conductor and/or grounding type 

attachment plug. To reduce the risk of electric shock, be certain that it is 

connected to a properly grounded grounding type receptacle.
In any installation where property damage and/or personal injury might result 

from an inoperative or leaking pump due to power outages, discharge line 

blockage, or any other reason, a backup system(s) and/or alarm should be used.
Support pump and piping when assembling and when installed. Failure to do so 

may cause piping to break, pump to fall, motor bearing failures, etc.
If pump is an oil-filled pump, the motor housing is filled with a dielectric lubricant 

at the factory for optimum motor heat transfer and lifetime lubrication of the 

bearings. Use of any other lubricant could cause damage and void the warranty. 

This lubricant is non-toxic; however, if it escapes the motor housing, it should 

be removed from the surface quickly by placing newspapers or other absorbent 

material on the water surface to soak it up, so aquatic life is undisturbed.
The National Electric Code (in the USA) and similar codes in other countries 

require a Ground Fault Circuit Interrupter (GFCI) to be installed in the branch 

circuit supplying fountain equipment rated above 15 volts.

ELECTRICAL CONNECTIONS

WARNING

1.  Check the pump label for proper voltage required. Do not connect to voltage 

other than that shown.

2.  If pump is supplied with a 3-prong electrical plug, the third prong is to ground 

the pump to prevent possible electrical shock hazard. DO NOT REMOVE the 

third prong from the plug. A separate branch circuit is recommended. Do not use 

an extension cord. Do not cut plug from the cord; this will void the warranty.

3.  If the cord is equipped with stripped lead wires, such as on 230v models, be sure 

that the lead wires are connected to a power source correctly. The green/yellow 

wire is the ground. The blue (or white) and the brown (or black) are live.

CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY 

AND DISASSEMBLY OF YOUR LITTLE GIANT PUMP.

OPERATION

WARNING

  1. This pump must be operated in clean fresh water with the volute intake below 

the liquid level.

  2. This pump can be placed in any position.
  3. The volute on this pump can be rotated 90° to allow for different pump orientations. 

To rotate the volute, remove the three volute screws (item 2). Remove and rotate 

the volute and gasket and reinstall the three screws in the additional holes in the 

front of the pump housing. NOTE: DO NOT USE EXCESSIVE TORQUE ON THE 

VOLUTE SCREWS; THIS COULD CAUSE THE HOLES TO STRIP OUT.

  4. The weight of the pump must be supported adequately. DO NOT support the 

pump by the discharge connection alone. Pump may be supported by using 

the two mounting holes in the back of the pump. The holes are designed for 

#8 self-tapping screws. DO NOT exceed the hole depth of .37".

  5. Do not restrict the intake side of the pump; this may cause damage to the 

Model • Modèle • Modelo

PE-1

Pump • Pompe • Bomba

seal and may starve the pump. If you require reduced flow rates, place a 

valve on the discharge side of the pump or, if flexible vinyl tubing is used, a 

clamp on the tubing to restrict the flow.

  6. Do not let the unit operate dry. It is designed to be cooled by pumping fluid. You 

may damage the seal and the motor may fail if the pump is allowed to run dry.

  7. If the unit is going to be idle for a period of time, follow the cleaning instructions 

outlined in the SERVICE INSTRUCTIONS section. Do not let the unit freeze in 

the wintertime. This may cause cracking or distortion that may destroy the unit.

  8. If fused type plug is used on 230 volt units, a 1.0 amp fuse is recommended.

SERVICE INSTRUCTIONS

WARNING

MAKE CERTAIN THAT THE UNIT IS DISCONNECTED FROM THE POWER 

SOURCE BEFORE ATTEMPTING TO SERVICE OR REMOVE ANY COMPONENT!
 1.  This unit is permanently lubricated. Oiling is not required. The power cord on these 

units cannot be replaced. In case of damage the whole unit must be replaced.

 2.  First remove the intake screen from the pump. Then remove the three screws as 

indicated by the arrows. (DO NOT remove other screws that may be exposed.)

 3.  Lightly clean any corrosion or debris which may clog the impeller. Use a brush 

and penetrating oil and lightly scrape to remove encrusted material.

 4.  Turn the impeller by hand to make sure it turns freely. Set pump down so the pump 

and impeller are not touching anything. Plug the unit into GFCI circuit for 10 seconds 

to see if the impeller turns; a) If it is rotating and GFCI did not trip, unplug unit and 

install parts in reverse order in which they were removed. b) If it does not rotate, if 

pump is tripping circuit breakers, or not operating properly after cleaning, return 

the pump to an authorized service center. DO NOT attempt repairs yourself.

 5.  Be certain power cord is in good condition and contains no nicks or cuts.

FR

INTRODUCTION

Cette feuille d’instructions vous fournit les informations nécessaires pour entretenir 

et faire fonctionner votre produit Little Giant. Conserver ces directives afin de pouvoir 

les consulter plus tard.
Le produit Little Giant que vous avez acheté a été soigneusement fabriqué avec des 

matériaux de la plus haute qualité et a été conçu pour durer longtemps et offrir un service 

fiable. Les produits Little Giant sont soigneusement testés, inspectés et emballés afin 

d’en assurer la sécurité de fonctionnement et une livraison en bonne condition. Vérifier 

attentivement le produit afin de vous assurer qu’il n’a pas été endommagé pendant le 

transport. S’il est endommagé, veuillez contacter l’entreprise qui vous l’a vendu. Si une 

réparation ou un remplacement est requis, elle vous prêtera assistance.
LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROCÉDER À 

L’INSTALLATION, À L’UTILISATION OU À L’ENTRETIEN DU PRODUIT LITTLE 

GIANT. SE FAMILIARISER AVEC LES APPLICATIONS, LES LIMITES ET LES 

RISQUES POTENTIELS DU PRODUIT. ASSURER SA PROPRE PROTECTION 

ET CELLE DES AUTRES EN SUIVANT TOUTES LES RÈGLES DE SÉCURITÉ. LE 

NON-RESPECT DE CES DIRECTIVES PEUT ENTRAÎNER DES BLESSURES ET/

OU DES DOMMAGES MATÉRIELS!

DIRECTIVES DE SECURITE

WARNING
AVERTISSEMENT 

AVERTISSEMENT

Veiller à débrancher l’appareil de sa source d’alimentation électrique avant 

l’entretien ou la dépose d’une ou de plusieurs piéces.
Ne pas pomper des fluides explosifs ou inflammables tels qu’essence, mazout, 

kérosène, etc. Ne pas employer dans une atmosphère comportant des risques 

de déflagration. La pompe ne doit servir qu’à pomper des liquides compatibles 

avec les matériaux utilisés pour la fabrication des éléments qui la composent.
Ne pas manipuler la pompe les mains humides, les pieds posés sur une surface 

mouillée ou humide, ou les pieds dans l’eau.
Cette pompe est équipée d’un conducteur de mise à la terre et ou d’une fiche de 

branchement à prise de terre. Pour réduire les risques d’électrocution, s’assurer qu’elle est 

bien raccordée à une prise de courant appropriée comportant une borne de mise à la terre.
Dans le cas de toute installation où des dommages matériels ou des blessures 

pourraient survenir par suite de l’emploi d’une pompe qui ne fonctionnerait pas 

ou qui fuirait à cause d’une panne de courant, d’une canalisation de refoulement 

bouchée ou de toute autre raison, prévoir l’emploi de(s) dispositif(s) de secours 

ou d’alarme voulu(s).
Veiller à bien étayer la pompe et la tuyauterie lors du montage et de la mise en place. 

Sinon, non seulement les tuyaux risqueraient de se déchirer mais la pompe pourrait 

également faire défaut et les roulements du moteur pourraient subir des dommages, etc.
Si la pompe est remplie d’huile. Ie carter est rempli d’huile diélectrique servant 

de caloporteur pour la chaleur engendrée par le moteur et de lubrifiant pour 

les paliers. L’emploi d’un autre lubrifiant quel qu’il soit pourrait endommager 

l’appareil et annuler la garantie. Bien que cette huile ne soit pas toxique, en cas 

de fuite, I’enlever rapidement à l’aide de journaux posés rapidement à la surface 

de l’eau pour que la vie aquatique ne soit pas perturbée.
Le code national de l’électricité et autres codes semblables d’autres pays exigent 

l’installation d’un interrupteur avec mise à la terre (GFI) sur le circuit d’alimentation 

de la fontaine pour toute installation dont la tension est supérieure à 15 volts.

Franklin Electric Co., Inc.

Oklahoma City, OK 73127

www.franklinwater.com

[email protected]

1

Form 994111 - 06/2013, Rev. 001