background image

PWM Series Wet Rotor Water Garden Pump

OWNER'S MANUAL

English

EN

The PWM Series pump are designed for high-flow applications. They are dura

-

ble and reliable for many water gardening applications, especially waterfalls. 
They are energy efficient, using up to 60% less electricity than direct drive 
pumps.
The pump does not use seals, and it does not contain oil. All electrical compo

-

nents, including the motor, are completely sealed in a non-toxic, plastic resin. 
The pump can be installed in-line by removing the bottom screen. It is 
equipped with a 20 ft (6.1 m) power cord.
This product is covered by a Limited Warranty for a period of 1 year from the 
date of original purchase by the consumer. For complete warranty information, 
refer to 

www.LittleGiant.com

 or call Technical Support for a printed copy.

Specifications

SAFETY INSTRUCTIONS

This equipment should be installed and serviced by technically qualified personnel who are familiar with 
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with 
national and local electrical and plumbing codes and within Little Giant recommendations may result in 
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product’s application, limitations, and potential hazards. Read and follow instructions carefully to 
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Failure to follow installation or operation procedures and all applicable codes may result in the following 
hazards:

Model

Item Number Amps Watts

Discharge

Suction

Max Height

PWM2600

517250

1.8

155

1 - 1/2" FNPT

(3.8 cm)

1 - 1/2" MNPT

(3.8 cm)

10.0 ft (3.0 m)

PWM3900

517251

2.4

280

12.7 ft (3.9 m)

PWM5200

517252

5.0

410

20.0 ft (6.1 m)

Risk of death, personal injury, or property damage due to explosion, 
fire, or electric shock.

• Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, 

etc.

• Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
• Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, 

or in water.

• When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged 

or electrically disconnected.

Содержание 517250

Страница 1: ...ational and local electrical and plumbing codes and within Little Giant recommendations may result in electrical shock or fire hazard unsatisfactory performance or equipment failure Know the product s application limitations and potential hazards Readand follow instructions carefully to avoid injury and property damage Do not disassemble or repair unit unless described in this manual Failure to fo...

Страница 2: ... and Health Act OSHA Do not use the power cord for lifting the pump The pump should only be used with liquids compatible with pump component materials If the pump is used with liquids incompatible with the pump components the liquid can cause failure to the electrical insulation system resulting in electrical shock Risk of bodily injury electric shock or equipment damage This equipment must not be...

Страница 3: ...end of the season Do not leave the pump out in freezing temperatures 1 Disconnect the power 2 Remove the pump from the water 3 Drain the pump 4 Remove the screen from the pump body 5 Carefully clean any debris from the impeller and pump housing 6 Rinse the unit with fresh water 7 Replace the screen 8 To store the pump Place the pump in a bucket of water to keep the seals from drying out Run the pu...

Страница 4: ...ectric Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com For technical assistance parts or repair please contact 10000008769 Rev 000 07 21 Copyright 2021 Franklin Electric Co Inc All rights reserved ...

Страница 5: ...dos El hecho de no cumplir con los códigos eléctricos y de plomería nacionales y locales y con las reco mendaciones de Little Giant puede provocar peligros de descarga eléctrica o incendio desempeños insatisfactorios o fallas del equipo Lea y siga las instrucciones cuidadosamente para evitar lesiones y daños a los bienes No desarme ni repare la unidad salvo que esté descrito en este manual El hech...

Страница 6: ... de Seguridad y Salud Ocupacionales OSHA No use el cable eléctrico para levantar la bomba La bomba solo se debe utilizar con líquidos compatibles con los materiales que componen la bomba Si la bomba se utiliza con líquidos incompatibles con los componentes de la bomba ellíquido puede causar fallas en el sistema de aislamiento eléctrico lo que resulta en una descarga eléctrica Riesgo de lesiones co...

Страница 7: ... agua para que no marche en seco 6 Conecte la tubería de descarga 7 Encienda la bomba enchufándola en un receptáculo con conexión a tierra adecuada No hay un inte rruptor de alimentación IMPORTANTE No permita que la unidad se congele ya que podría destruirla MANTENIMIENTO Limpie la bomba periódicamente y al final de la temporada o cuando se observe una disminución en el flujo No deje la bomba afue...

Страница 8: ...cuito GFCI dedicado La bomba no está cebando Asegúrese de que la entrada de la bomba esté debajo del agua Si se usa en línea toda la bomba debe estar debajo del agua Flujo de agua bajo de la bomba La entrada de la bomba está bloqueada Quite los desechos que bloquean la rejilla de entrada o el impulsor La bomba no es lo sufi cientemente grande Seleccione una bomba de mayor capacidad La descarga de ...

Страница 9: ...t national et des recommandations de Little Giant pourrait mener à une électrocution ou un incendie une mauvaise performance ou une défaillance de l équipement Lisez et suivez attentivement les instructions pour éviter toute blessure ou tout dommage matériel Ne démontez pas et ne réparez pas l appareil si ces opérations ne sont pas décrites dans le présent manuel Le non respect des procédures d in...

Страница 10: ... La pompe doit être utilisée uniquement avec des liquides compatibles avec les matériaux de ses composants Si la pompe est utilisée avec des liquides incompatibles avec les composants de la pompe le liquide peut provoquer une défaillance du système d isolation électrique entraînant un choc électrique Risque de blessure de choc électrique ou de dégâts matériels Cet équipement ne doitpas être utilis...

Страница 11: ...éviter qu elle sèche 6 Raccordez la tuyauterie de refoulement 7 Démarrez la pompe en la branchant dans une prise correctement mise à la terre Il n y a pas d interrup teur d alimentation IMPORTANT Ne laissez pas l appareil geler car cela pourrait le briser ENTRETIEN Nettoyez la pompe de façon périodique ou lorsqu une baisse de débit est constatée ainsi qu en fin de sai son Ne laissez pas la pompe e...

Страница 12: ...it dédié équipé d une prise DDFT La pompe ne s amorce pas Assurez vous que l entrée de la pompe se trouve sous la surface de l eau Si elle est utilisée sur un réseau la pompe doit être entièrement immergée Faible débit d eau de la pompe L entrée de la pompe est bloquée Retirez les débris bloquant l écran d entrée ou la roue La pompe n est pas assez grande Sélectionnez une pompe de plus grande capa...

Отзывы: