MAINTENANCE

s

!

CAUTION

 When working on the pump or switch, 

always unplug the pump power cord in addition to removing the fuse 
or shutting off the circuit breaker before working on the pump.

This unit is permanently lubricated. Oiling is not required.  
Do not, in any case, open the sealed portion of the unit  
or remove housing screws.

s

!

NOTICE

 Inspect and test the sump system  

condition and operation every 3 months (more frequently  
in heavy use applications).

1.  LET PUMP COOL FOR A MINIMUM OF 2 HOURS BEFORE  

ATTEMPTING TO SERVICE.

a. Submersible pumps contain oil that becomes pressurized 

and hot under normal operating conditions.

2.  Check the power cords and electrical outlet for  

damage or corrosion.

a. The power cord on these units cannot be replaced.  

In case of damage the whole unit must be replaced.

3.  Remove all debris (gravel, sand, floating debris, etc.)  

from the sump basin.

4.  Review sump system components for any build-up (minerals, 

etc.) that would inhibit functionality of the components.

a. If significant, remove build-up or replace  

affected components.

5.  Confirm that all flexible coupling hose clamps are fully engaged 

with plumbing and fully tightened.

6.  Test operation of the sump system following the instructions 

outlined in the “Sump System Operation Testing” section  
of this manual.

7.  While the pump is running, make sure a stream of water is 

escaping from the air bleed hole.

a. If not, clear the hole of any deposits or debris.

CLEANING IMPELLER AND VOLUTE

Periodic cleaning of the pump parts will prolong the life and  
efficiency of the pump. Refer to the assembly and disassembly  
of the pumping head.

1.  Remove the 5 screws that hold the base to the volute,  

then separate the base from the volute.

2. 

s

!

WARNING

 Do not remove the motor 

housing cover. Warranty is void if the motor housing cover, 
impeller or seals have been removed. 

a. Any repair on the motor must be done by an authorized 

Little Giant service center.

3.  Remove the base and clean the impeller and the volute passage. 

Do not use strong solvents on the impeller.

a. 

s

!

CAUTION

 Do not remove the impeller. 

Removal of the impeller requires special tools and is to be 
done only by an authorized service center.

4.  Be sure the impeller turns freely after cleaning.

5.  Attach the base to the volute and secure it with the 5 screws.

CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY 
AND DISASSEMBLY OF YOUR LITTLE GIANT PUMP.

W A R N I N G

W A R N I N G

Содержание 10EC-CIA-SFS

Страница 1: ...STOCK No 53DH04 MODEL 6EC CIA SFS STOCK No 53DH05 MODEL 6EC CIM STOCK No 53DH06 MODEL 10EC CIA SFS Installation Guide ...

Страница 2: ...NGMake certain that the unit is disconnected from the power source before attempting to service or remove any component If the power disconnect is out of sight lock it in the open position and tag it to prevent unexpected application of power s WARNINGThis equipment should be installed and serviced by technically qualified personnel Comply with national and local electrical and plumbing codes when...

Страница 3: ...rted 2 Introduction 4 Safety Guidelines 4 Installation 5 Typical Installation 6 Wiring 7 Specifications 7 Sump System Operation Testing 8 Maintenance 9 Pump Performance Curves 10 Troubleshooting 10 Replacement Parts 11 Limited Warranty 15 ...

Страница 4: ...they are not call a qualified licensed electrician s WARNINGThe pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly Protector tripping is an indication of motor overloading overheating which can be caused by application issues such as an obstructed pump impeller switch stuck in ON position pump running dry pump air locked pump short cycling excessively...

Страница 5: ... comes with 1 1 2 female pipe thread discharge a Support pump and piping when assembling and when installed Failure to do so may cause piping to break pump to fail motor bearing failures etc b Always install a union in the discharge line just above the sump pit to allow for easy removal of the pump for cleaning or repair 6 A check valve must be used in the discharge line to prevent back flow of li...

Страница 6: ...mp outlet Pump Power Grommet Sump Cover 2 or 3 Vent Pipe 3 16 dia Bleed Hole in Discharge Pipe Gas tight Basin 18 dia x 24 deep min Union Check Valve Gate Valve Pump Place pump on hard level surface Never place directly on clay earth or gravel surface SFS Models 7 10 on level SFS Models 2 5 off level TYPICALINSTALLATION ...

Страница 7: ...ump must not be modified in any way with the exception of shortening the cord to fit into a control panel Any splice between the pump and the control panel must be made within a junction box and mounted outside of the basin and comply with the National Electrical Code Do not use the power cord for lifting the pump SPECIFICATIONS Gallons Per Minute at Height Liters Per Minute at Height Shut Off 5 1...

Страница 8: ...rol The pump cord for these pumps can be plugged directly into a properly grounded receptacle with voltage consistent with pump nameplate for continuous pump operation a s CAUTIONThis type of operation should be used only for emergency use or when a large volume of water is to be pumped The pump must be continuously monitored during operation and disconnected from power before the pump runs dry b ...

Страница 9: ...are fully engaged with plumbing and fully tightened 6 Test operation of the sump system following the instructions outlined in the Sump System Operation Testing section of this manual 7 While the pump is running make sure a stream of water is escaping from the air bleed hole a If not clear the hole of any deposits or debris CLEANING IMPELLER AND VOLUTE Periodic cleaning of the pump parts will prol...

Страница 10: ...installed properly Check valve stuck or plugged Remove check valve and inspect for proper operation Lift too high for pump Check rating table Inlet to impeller plugged Pull pump and clean Pump is air locked Pull pump and clean Pump does not deliver rated capacity Lift too high for pump Check rated pump performance Low voltage speed too slow Check for proper supply voltage to make certain it corres...

Страница 11: ...itch 20 Cord 1 110970103 Cover Assembly 115 V Manual 20 Cord 1 110970201 Capacitor Kit 115 V with Bracket Seal Ring 2 110970301 Float Assembly with Stem Strap 3 110970401 Volute Base Plastic with Gasket for 6E 4 110970403 Volute Base Plastic with Gasket for 10EC 4 REPLACEMENTPARTS ...

Страница 12: ...12 NOTES ...

Страница 13: ...13 NOTES ...

Страница 14: ...14 ...

Страница 15: ...cordance with the Company s published instructions applicable codes applicable ordinances and or with generally accepted industry standards 3 Any product that has been subject to misuse misapplication neglect alteration accident abuse tampering acts of God including lightning acts of terrorism acts of war fire improper storage or installation improper use improper maintenance or repair damage or c...

Страница 16: ...OSSIBLE THIS PARAGRAPH SHALL ALSO APPLY TO ALL DAMAGES RESULTING FROM CONDITIONS SET FORTH IN SECTION III ABOVE AND 1 DEFECTS IN PRODUCT PROTOTYPES OR REPLACEMENT PART PROTOTYPES THAT HAVE NOT BEEN PUT INTO PRODUCTION CIRCULATED AND SOLD BY THE COMPANY AND OR 2 DEFECTS THAT WERE NOT FOUND AT THE TIME OF SALE DUE TO SCIENTIFIC AND TECHNOLOGICAL REASONS This Limited Warranty gives you specific legal...

Отзывы: