background image

 2.  Turn the impeller by hand to make sure it is free. If it does 

not turn or if pump is tripping circuit breaker, or not operating 
properly after cleaning, return to Little Giant or its authorized 
service center. Do not attempt repairs yourself. If it does turn, 
replace volute and re-install into parts washer.

 3.  Be certain power cord is protected from solvent and has no 

nicks or cuts.

Do not remove housing screws. Will void warranty.

5

1

2

3

4

Figure 2

TROUBLESHOOTING

CAUTION:

 Do not open the sealed portion of the unit or remove 

the housing screws.
 1.  Should the unit fail to operate, check the following:

 a.  Power supply and connections

Form 993855 - 12/2007

© 2007 Franklin Electric Co., Inc.

Little Giant® is a registered trademark of Franklin Electric Co., Inc.

 b.  Is the pump below liquid level?
 c.  Is air trapped in the pump head?
 d.  Is there sediment build-up over pump inlet?

 2.  An air lock or bubble will prevent the unit from pumping. 

Trapped air can usually be removed by turning the pump 
off and restarting. Ensure that the discharge line is sloping 
upward to prevent formation of air pockets.

 3.  If these operations do not restore the unit to full service, call 

your dealer or service technician. 

REPLACEMENT PARTS

ITEM

PART NO.

DESCRIPTION

QTY.

1

101903

Screen

1

2

902411

Screw, 8-18 X 1”

2

3

101351

Volute

1

4

101433

Impeller assembly

1

5

902408

Screw, #8 self-tapping

1

LITTLE GIANT WARRANTY STATEMENT

Your Little Giant product is guaranteed to be in perfect condition when it leaves 

our Factory. It is warranted against defective materials and workmanship for 

a period of 12 months from date of purchase by the user. Any product that 

should fail for either of the above two reasons and is still within the warranty 

period, will be repaired or replaced if returned prepaid to our Factory. All 

defective products returned under warranty will be fully inspected to determine 

“CAUSE OF FAILURE” before any warranty is approved. Little Giant will honor 

the warranty within the warranty time period specified on satisfactory written 

proof of purchase.
DISCLAIMER: Any oral statements about the product made by the seller, 

the manufacturer, the representatives or any other parties, do not constitute 

warranties, shall not be relied upon by the user, and are not part of the contract 

for sale. Seller’s and manufacturer’s only obligation, and buyer’s only remedy, 

shall be the replacement and/or repair by the manufacturer of the product as 

described above. Neither seller nor the manufacturer shall be liable for any 

injury, loss or damage, direct, incidental or consequential (including, but not 

limited to, incidental or consequential damages for lost profits, lost sales, injury 

to person or property, or any other incidental or consequential loss), arising 

out of the use or the inability to use the product, and the user agrees that no 

other remedy shall be available to it. Before using, the user shall determine 

the suitability of the product for his intended use, and user assumes all risk of 

liability whatsoever in connection therewith. The warranty and remedy described 

in this limited warranty is an EXCLUSIVE warranty and remedy and is IN LIEU 

OF any other warranty or remedy, expressed or implied, which other warranties 

and remedies are hereby expressly EXCLUDED, including but not limited to 

any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR 

PURPOSE. Some states do not allow the exclusive or limitation of incidental or 

consequential damages, so the above limitation or exclusion may not apply to 

you. This warranty gives you specific legal rights, and you may also have other 

rights which vary from state to state.

Warranty will be VOID if any of the following conditions are found:
 1.  Sealed motor housing opened.
 2.  Product connected to voltage other than indicated on name plate.
 3.  Cord cut off to a length less than three feet.
 4.  Pump allowed to operate dry (fluid supply cut off).
 5.  Product abused by customer.
 6.  Pump used to circulate anything other than room temperature PJQU, UL 

Classified Metal Parts Cleaning Solvents with a minimum flash point of 

100 deg. F. Highly flammable fluids such as gasoline, some chlorinated 

solvents, alcohols, acetone, or toluol should not be used. These fluids are 

dangerous and may cause explosions or fire.

For parts or repair, please contact  . . . . . . . . . . . . . . . . . . . . 1.888.572.9933

For technical assistance, please contact  . . . . . . . . . . . . . . . 1.888.956.0000

www.LittleGiantPump.com

[email protected]

Отзывы: