2. Turn the impeller by hand to make sure it is free. If it does
not turn or if pump is tripping circuit breaker, or not operating
properly after cleaning, return to Little Giant or its authorized
service center. Do not attempt repairs yourself. If it does turn,
replace volute and re-install into parts washer.
3. Be certain power cord is protected from solvent and has no
nicks or cuts.
Do not remove housing screws. Will void warranty.
5
1
2
3
4
Figure 2
TROUBLESHOOTING
CAUTION:
Do not open the sealed portion of the unit or remove
the housing screws.
1. Should the unit fail to operate, check the following:
a. Power supply and connections
Form 993855 - 12/2007
© 2007 Franklin Electric Co., Inc.
Little Giant® is a registered trademark of Franklin Electric Co., Inc.
b. Is the pump below liquid level?
c. Is air trapped in the pump head?
d. Is there sediment build-up over pump inlet?
2. An air lock or bubble will prevent the unit from pumping.
Trapped air can usually be removed by turning the pump
off and restarting. Ensure that the discharge line is sloping
upward to prevent formation of air pockets.
3. If these operations do not restore the unit to full service, call
your dealer or service technician.
REPLACEMENT PARTS
ITEM
PART NO.
DESCRIPTION
QTY.
1
101903
Screen
1
2
902411
Screw, 8-18 X 1”
2
3
101351
Volute
1
4
101433
Impeller assembly
1
5
902408
Screw, #8 self-tapping
1
LITTLE GIANT WARRANTY STATEMENT
Your Little Giant product is guaranteed to be in perfect condition when it leaves
our Factory. It is warranted against defective materials and workmanship for
a period of 12 months from date of purchase by the user. Any product that
should fail for either of the above two reasons and is still within the warranty
period, will be repaired or replaced if returned prepaid to our Factory. All
defective products returned under warranty will be fully inspected to determine
“CAUSE OF FAILURE” before any warranty is approved. Little Giant will honor
the warranty within the warranty time period specified on satisfactory written
proof of purchase.
DISCLAIMER: Any oral statements about the product made by the seller,
the manufacturer, the representatives or any other parties, do not constitute
warranties, shall not be relied upon by the user, and are not part of the contract
for sale. Seller’s and manufacturer’s only obligation, and buyer’s only remedy,
shall be the replacement and/or repair by the manufacturer of the product as
described above. Neither seller nor the manufacturer shall be liable for any
injury, loss or damage, direct, incidental or consequential (including, but not
limited to, incidental or consequential damages for lost profits, lost sales, injury
to person or property, or any other incidental or consequential loss), arising
out of the use or the inability to use the product, and the user agrees that no
other remedy shall be available to it. Before using, the user shall determine
the suitability of the product for his intended use, and user assumes all risk of
liability whatsoever in connection therewith. The warranty and remedy described
in this limited warranty is an EXCLUSIVE warranty and remedy and is IN LIEU
OF any other warranty or remedy, expressed or implied, which other warranties
and remedies are hereby expressly EXCLUDED, including but not limited to
any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. Some states do not allow the exclusive or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to
you. This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
Warranty will be VOID if any of the following conditions are found:
1. Sealed motor housing opened.
2. Product connected to voltage other than indicated on name plate.
3. Cord cut off to a length less than three feet.
4. Pump allowed to operate dry (fluid supply cut off).
5. Product abused by customer.
6. Pump used to circulate anything other than room temperature PJQU, UL
Classified Metal Parts Cleaning Solvents with a minimum flash point of
100 deg. F. Highly flammable fluids such as gasoline, some chlorinated
solvents, alcohols, acetone, or toluol should not be used. These fluids are
dangerous and may cause explosions or fire.
For parts or repair, please contact . . . . . . . . . . . . . . . . . . . . 1.888.572.9933