INTRODUCTION

The 1-YS pump is designed for submerged use only. Its motor is 
hermetically sealed in a diecast aluminum housing, which is oil-filled 
for heat transfer and permanent lubrication. It is intended to pump 
unheated metal parts-cleaning solvent that is UL classified as PJQU 
as described in the Gas and Oil Equipment Directory. These are 
refined petroleum distillates that are free from the tendency to heat 
spontaneously. They have a closed cup flash point not lower than 100 
degrees F. These are typical fluids that are compatible with the pump 
materials (except the power cord.) See Installation step 1.

NOTE:

 This pump is intended for use only in parts cleaners 

listed by Underwriters Laboratories. The combination of the fluid 
pumped, the pump, and the design of the parts washer will 
determine if additional safety devices, such as a low liquid level cut 
off, are required. Refer to parts washer manufacturer’s instructions 
to see if this is required.

SAFETY GUIDELINES

Before servicing the pump, see solvent and equipment 
manufacturer’s instructions for further safety information and 
possible hazards.
Follow all local electrical and safety codes, as well as the National 
Electrical Code (NEC) and the Occupational Safety and Health Act 
(OSHA).
This pump must be properly grounded while in use to protect the 
operator from electrical shock.
Always disconnect power source before working on the pump. If 
the power disconnect point is out of sight, lock in the open position 
and tag to prevent unexpected application of power.
Do not attempt to make your own parts cleaners.
The low flash point of these combustible liquids does present 
a moderate fire hazard. Operating the pump fully submerged 
offers added protection from fire risk. For other solvent handling 
precautions, consult the material safety data sheet (OSHA-20 form, 
or equivalent) for the solvent used.
Use only UL-approved metal parts cleaning solvents. The use of fluids 
such as gasoline and lower flash point solvents is dangerous and 
may cause explosions or fire. Solvents other than UL-approved metal 
parts cleaning solvents will void the warranty of this product.

SPECIFICATIONS

Suction inlet ............................... Smooth opening, approx. ½” I.D.
Discharge outlet .................................................... 1/4” NPT (male)
Cord type ......................................................................18/3 (SJTO)
Pipe connector around cord ................................  1/2” NPT (male)
Pump housing (volute) .......................................................... Nylon
Motor housing ..............................  Die-cast aluminum (unpainted)
Impeller .................................................  Nylon (with S.S. bushing)
Pump screen .............................................................. Polyethylene
Pump shaft seal ....................................................................... Viton
Motor shaft ......................................................................... 440 S.S.
Volute & pump screws .................................. 410 S.S. or 18-8 S.S.
Overall dimensions ...................................... 4” dia. x 4-1/4” height
Maximum fluid temperature ...................................................100° F

INSTALLATION

WARNING:

 Do not allow the pump’s power cord to come in 

contact with solvent. The solvent may damage the cord insulation, 
causing the cord to become stiff or lower its insulating properties. 
The pump is supplied with a three-conductor power cord. The third 
conductor is to ground the pump to prevent possible electrical 
shock hazard.
 1. Seal the power cord inside of liquid-tight, ½” NPT steel 

intermediate metal conduit. Use caution to ensure that cord will 
not be nicked or cut.

 2.  Consult pump nameplate data for proper voltage and frequency. 

Please note, the black (or brown) and white (or blue) wires are 
live and the green (or green/yellow) wire is ground.

 3.  Be sure that the pump is fully submerged in the cleaning 

solvent.

 4.  The pump power supply cord must be connected to a properly 

grounded, grounding-type receptacle.

PERFORMANCE

(115V 60HZ)

MODEL

GALLONS PER HOUR

SHUT-OFF 

PSI

1’

3’

5’

7.5’

1-YS

180

144

102

0

3.2

Figure 1

MAINTENANCE

WARNING:

 UNPLUG THE UNIT BEFORE ATTEMPTING TO 

SERVICE OR REMOVE ANY COMPONENT!

CAUTION:

 This unit is permanently lubricated. Oiling is not 

required. Do not open the sealed portion of the unit or remove 
housing screws.
Periodic cleaning of the pump parts will prolong the life and 
efficiency of the pump. Refer to Fig. 2 for the assembly and 
disassembly of the pumping head.
 1.  Lightly clean any corrosion or debris that may clog the impeller. 

Use a brush and penetrating oil and lightly scrape. NOTE: Do 
not allow sediment from parts being washed to build up and 
restrict the flow of fluid into the pump.

SUBMERSIBLE 

PUMP

MODEL 1-YS

CATALOG NUMBER 501020 

OR 501030