Little Giant 1-EAYS Скачать руководство пользователя страница 1

ATTENTION: READ CAREFULLY BEFORE INSTALLING, OPERATING 

OR SERVICING YOUR LITTLE GIANT SUBMERSIBLE PUMP. KEEP THIS 

INSTRUCTION SHEET FOR FUTURE USE!
CAUTION: Improper use of any power equipment can result in prop-

erty damage, and/or injury. Protect yourself and others by using com-

mon sense and by observing the safety information in this publication

INSTALLATION (FIg. 1)

1.    Thread power cord of pump through conduit (extending from under 

the wash basin) and attach the conduit to the conduit fitting at 

cord outlet. Rigid metal conduit stand pipe must be attached to the 

conduit fitting in order to protect the electrical cord. Be sure that the 

discharge of the pump is in line with the flexible tubing (extending 

from under the wash basin). WARNING: Power cord supplied with 

this pump should not be in contact with the solvent. The solvent can 

dissolve the cord insulation causing an electrical short which can 

lead to possible injury.

2.   Attach the flexible tubing to the ¼" NPT discharge; tighten the 

threaded coupling securely.

3.    This pump is equipped with a three-wire power cord with a grounding 

wire for your protection against shock hazard andshould be connected 

to a three-pronged plug or wired directly to anon/off power switch 

(whichever is used on the parts washer). Consult nameplate data for 

proper voltage and frequency. Please note, the black and white or 

blue and brown wires are live and the green or green/yellow wire is 

the ground wire.

4.   Place pump/wash basin properly on holding tank; be sure that 

the pump is submerged in the cleaning solvent. See parts washer 

instruction for proper level of cleaning solvent. These pumps were 

tested while operating dry and within an enclosure. The resulting 

temperature rise may require a low liquid level cut-off to be present in 

this end use application.

 DESCRIPTION

This pump is intended for indoor use pumping combustible liquids 

typically used in UL listed parts cleaners. For use only in products where 

the acceptability of the combination is determined by Underwriters 

Laboratories, Inc.
Little Giant 1-EAYS epoxy encapsulated, centrifugal pump is designed to 

be used for submerged parts washer application only. The 1-EAYS can 

handle unheated liquids up to 100° F. that are compatible with the pump 

material, such as UL Classified Metal Parts Cleaning Solvents with 100° F. 

flash point or greater.
Caution: The low flash point of these solutions presents a potential fire 

hazard; the entire pump must be fully submerged while operating. For 

solvent handling precautions, consult the safety data sheet (Form OSHA-

20, or equivalent) for the particular cleaning solution. The motor is epoxy 
encapsulated with a polyester case.

PERFORMANCE

(115V 60HZ)

Model

gallons Per Hour

Shut-Off

(PSIg)

1 ft.

3 ft.

5 ft.

7 ft.

1-EAYS

170

140

100

Shut-Off

3.0

 SPECIFICATIONS

Model No.

1-EAYS

Suction Inlet

Smooth Opening Approx. ½" I.D.

Discharge Outlet

¼" NPT (Male)

Cord Length

Approx. 6 Feet (SJTO)

Pipe Connector Around Cord

Male Conduit Fitting

Pump Housing (Volute)

Nylon

Motor Plate

Epoxy Coated Die Cast Aluminum

Motor Case

Epoxy Filled Polyester

Impeller

Nylon

Pump Screen

Polyethylene

Pump Shaft Seal

Fluoroelastomer (FKM)

Motor Shaft

440 S.S.

Volute & Pump Screws

410 S.S. or 18-8 S.S.

Overall Dimensions

3.2" L x 2.8" W x 3.6" H

Maximum Liquid Temperature

100° F.

 

MAINTENANCE

CAUTION: UNPLUG THE UNIT BEFORE ATTEMPTING TO SERVICE OR 

REMOVE ANY COMPONENT!
1.    This unit is self-lubricating. Oiling is not required.
2.    Periodic cleaning of the pump parts will prolong the LIFE and EFFICIENCY 

of the pump. Refer to Fig. 2 for the assembly and disassembly of the 

pumping head.

3.    Lightly clean any corrosion or debris which may clog the impeller. Use a 

brush and penetrating oil and lightly scrape. Note: Do not allow sediment 

(from parts being washed) to build up to more than 2" below the pump.

4.    Turn the impeller by hand to make sure it is free. Plug the unit in for a few 

seconds to see if the impeller will turn. If it does, replace the front, and the 

unit should operate as good as new.

TROUBLESHOOTINg  

1.    Should the unit fail to operate, check the following:

    a. Power supply connections.
    b. Is the pump below liquid level?
    c. Is air trapped in the pump head?
    d. Is there sediment build-up over pump inlet?

2.    An air lock or bubble will prevent the unit from pumping. Trapped air 

can usually be removed by:

    a. Turning the pump off and restarting.
    b. Ensuring that the discharge line is sloping upward to  

 

  prevent formation or air pockets

3.    If for any reason these operations do not restore the unit to full
    service, call your dealer or service man.
4. Do not, in any case, open the sealed portion of the unit.   

TYPICAL INSTALLATION (SEE FIg. 1)

PUMP TO BE EITHER WIRED INTO ON/OFF SWITCH BOX OR A 3-PRONG PLUG 

ATTACHED TO PUMP CORD AND PLUGGED INTO ON/OFF RECEPTACLE.

1

INSTALLATION INSTRUCTIONS & PARTS LIST

LITTLE gIANT SUBMERSIBLE PUMP MODEL 1-EAYS

518020 115V 60 HZ

Franklin Electric Co., Inc.

Oklahoma City, OK 73127

www.franklinwater.com

[email protected]

Form 993119 - 07/2013, Rev. 001