background image

page 9

Troubleshooting.

Problem: 

Fan fails to operate.

Solutions:

1. Check wall switch to fan.
2. Verify that reverse switch is set completely in 
either direction.
3. Check to be sure fan is wired properly.

Problem: 

Light kit (optional) not lighting.

Solutions:

1. Check wall switch to fan.
2. Check that bulbs are installed correctly.
3. Check to be sure wires in canopy are wired 
properly.
4. Verify that molex connections are connected 
properly in switch housing.

Problem: 

Fan operates but light fails (if applicable).

Solutions: 

1. Check that bulbs are installed correctly.
2. Check to be sure wires in canopy are wired 
properly.
3. Verify that molex connections are connected 
properly in switch housing.
4. Replace defective bulbs with same type of bulb.

Problem: 

Fan wobbles.

Solutions:

1. Use the balancing kit in one of the hardware 
packs. 

If no blade balancing kit is provided, please 

call Customer Support, at 1-800-527-1292, to request 
one.

2. Check to be sure set screw(s) on motor housing 
yoke is (are) tightened securely.
3. Check to be sure set screw on hanging ball is 
tightened securely.

Warranty.

Parts Replacement.

For parts and information, please refer to
"Parts Inventory" on page 2.
Litex Customer Support:

1-800-527-1292

KHLI1801

LITEX 30-YEAR LIMITED WARRANTY:
LITEX INDUSTRIES, LTD. warrants this fan to the original 
household purchaser for indoor use under the following 
provisions:
1-YEAR WARRANTY: LITEX INDUSTRIES, LTD. will replace or 
repair any fan which has faulty performance due to a 
defect in material or workmanship. Contact Litex Customer 
Service at 

1-800-527-1292

 to arrange for return of fan. 

Return fan, shipping prepaid, to Litex Industries, Ltd. We will 
repair or ship you a replacement fan, and we will pay the 
return shipping cost.
5-YEAR WARRANTY: LITEX INDUSTRIES, LTD. will repair or 
replace, at no charge to the original purchaser, any fan 
motor that fails to operate satisfactorily when failure 
results from normal use.
RETURN FAN MOTOR ONLY, shipping prepaid, to Litex 
Industries. We will repair or ship purchaser a replacement 
motor and Litex will pay the return shipping cost.
6-YEAR to 30-YEAR LIMITED WARRANTY: LITEX INDUSTRIES, 
LTD. will repair the fan, at no charge to the original 
purchaser for labor only, if the fan motor fails to operate 
satisfactorily when failure results from normal use. Parts 
used in the repair will be billed to the purchaser at 
prevailing prices at time of repair.
    The purchaser shall be responsible for all costs incurred 
in the removal, reinstallation and shipping of the product 
for repairs.
    This warranty does not apply when damage from 
mechanical, physical, electrical or water abuse results in 
causing the malfunction. Deterioration of finishes or other 
parts due to time or exposure to salt air is specifically 
exempted under this warranty.
    Neither Litex Industries nor the manufacturer will 
assume any liability resulting from improper installation or 
use of this product. In no case shall the company be liable 
for any consequential damages for breach of this, or any 
other warranty expressed or implied whatsoever. This 
limitation as to consequential damages shall not apply in 
states where prohibited.

Содержание 1158921

Страница 1: ...allation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 6 Blade Assembly pg 7 Light Kit Assembly Optional pgs 7 8 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty p...

Страница 2: ...n 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference...

Страница 3: ...y 1 piece b hanging bracket 1 piece c downrod and hanging ball with pin and clip 1 piece d motor housing 1 piece e yoke cover 1 piece f blade arm 5 pieces g switch housing cap 1 piece h blade 5 pieces...

Страница 4: ...iginal outlet box If installing on a vaulted ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the ha...

Страница 5: ...as having a set screw hole use this hole when setting the set screw Insert stop pin into top of extended downrod and raise hanging ball Be sure stop pin aligns with slots on the inside of the hanging...

Страница 6: ...ide canopy cover to reveal 6 holes Refer to diagram 1 Notice that 3 of these holes are larger Locate 6 screws in top of motor housing yoke Observe that 3 of the screw heads are almost flush with the y...

Страница 7: ...or provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wire connector provided If you intend to control the fan light with a separate light switch connect BL...

Страница 8: ...x nut lock washer 10 Light Kit Assembly Remove 3 screws from switch housing cap If you wish to use fan WITHOUT the light kit align holes in switch housing cap with holes in switch housing Note The gap...

Страница 9: ...lign holes in light kit fitter with holes in switch housing Note The gap on the top edge of the switch housing cap must align with the reverse switch on the switch housing for the proper fit Attach li...

Страница 10: ...to a defect in material or workmanship Contact Litex Customer Service at 1 800 527 1292 to arrange for return of fan Return fan shipping prepaid to Litex Industries Ltd We will repair or ship you a re...

Отзывы: