Liteink VM-1004 Скачать руководство пользователя страница 2

Installation Instructions 

 

The diagram below shows a typical installation of the VM-1004 Video 
Distribution Amplifier Module.   A single input signal is split and routed 
to three separate isolated video outputs.  Since the system is DC 
coupled, all portions of the video signal are passed to the various 
outputs.  The VM-1004 also contains an alarm scheme that will sense 
the loss of an input signal and trigger an integral ALARM indicator as 
well as activate an optional ALM-1000 Alarm Sensing Module.  A rear 
panel switch allows this feature to be turned off if so desired. 
 

 

 

 

Power Terminal Block Connections 

 

Pin Function 

Alarm output for use with optional Alarm Sensing Unit 
ALM-1000. No other connections should be made to this 
terminal 

+11 to 24 DC or AC Volts input 

AC or DC return (Common to Housing) 

 

Be certain to check all connections, settings and voltages before 
applying power  
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

106724 Rev F 

 
 
 

Indicator Lights 

 

Indicator Lights 

when 

 

Pwr 

Proper power is present. 

Alrm 

The loss of video alarm is activated and there is 
no signal present 

Sig 

A signal is present. 

 
 
The 

Alarm

 switch is used to turn the alarm function on and off. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Typical Fiber Optic CCTV Distribution System

Fiber Optic

Cable

Camera

Monitor

VT-1001

VR-1001

ALM-1000

Alarm

Contacts

VM-1004

Monitor Monitor